Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14

Explosion protection is indispensable in the industry operating in an atmosphere filled with combustible substances. Intrinsic safety (Ex i) is one of the explosion protection methods which can restrict the energy entering the hazardous area and limit the energy reserved in the field devices. Furthe...

Full description

Bibliographic Details
Main Author: Cham, Leslie Yeong Lie
Format: Final Year Project / Dissertation / Thesis
Published: 2022
Subjects:
Online Access:http://eprints.utar.edu.my/5385/
http://eprints.utar.edu.my/5385/1/MH_1900592_Final_%2D_CHAM_YEONG_LIE_LESLIE.pdf
_version_ 1848886402034434048
author Cham, Leslie Yeong Lie
author_facet Cham, Leslie Yeong Lie
author_sort Cham, Leslie Yeong Lie
building UTAR Institutional Repository
collection Online Access
description Explosion protection is indispensable in the industry operating in an atmosphere filled with combustible substances. Intrinsic safety (Ex i) is one of the explosion protection methods which can restrict the energy entering the hazardous area and limit the energy reserved in the field devices. Furthermore, it is mostly applied in the control and instrumentation system. The project aims to examine the conformity of various Ex i systems as per IEC 60079-14. The objectives are to verify the compliance of the apparatuses and carry out the analysis on the intrinsic safety loop verification. Additionally, the emphasis is put on the verification regarding the validity of the Ex i systems that implement temperature sensing and the controlling of the solenoid valve. Throughout the project, the experiment and site visit are not implemented. The specifications of the apparatuses and the configuration of the Ex i systems are obtained from the datasheets of the companies specializing in explosion protection such as Eaton MTL, Pepperl+Fuchs and Phoenix Contact. Based on the parameters and certification of conformity shown in the datasheets, the compliance of apparatuses and intrinsic safety loop can be examined. In this project, the conformity of four Ex i systems has been validated in terms of the compliance of the apparatuses and the intrinsic safety loop verification. The ways to implement the validation regarding the compliances of various apparatuses including temperature transducer, digital display, temperature sensors, solenoid valves and intrinsic safety barriers have been demonstrated. Furthermore, the proper way to utilize the energy curves in the verification of the safety parameters is covered. Apart from that, the intrinsic safety loop verification of several Ex i system configurations is executed. In addition, the flowcharts and equations are presented to interpret the intrinsic safety loop verification more understandably. In short, the conformity of all of the four Ex i systems is proven and the detailed steps of the verification are shown, thus providing clearer guidelines on the implementation of Ex i method as per IEC 60079-14.
first_indexed 2025-11-15T19:37:55Z
format Final Year Project / Dissertation / Thesis
id utar-5385
institution Universiti Tunku Abdul Rahman
institution_category Local University
last_indexed 2025-11-15T19:37:55Z
publishDate 2022
recordtype eprints
repository_type Digital Repository
spelling utar-53852023-06-16T14:02:15Z Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14 Cham, Leslie Yeong Lie TJ Mechanical engineering and machinery Explosion protection is indispensable in the industry operating in an atmosphere filled with combustible substances. Intrinsic safety (Ex i) is one of the explosion protection methods which can restrict the energy entering the hazardous area and limit the energy reserved in the field devices. Furthermore, it is mostly applied in the control and instrumentation system. The project aims to examine the conformity of various Ex i systems as per IEC 60079-14. The objectives are to verify the compliance of the apparatuses and carry out the analysis on the intrinsic safety loop verification. Additionally, the emphasis is put on the verification regarding the validity of the Ex i systems that implement temperature sensing and the controlling of the solenoid valve. Throughout the project, the experiment and site visit are not implemented. The specifications of the apparatuses and the configuration of the Ex i systems are obtained from the datasheets of the companies specializing in explosion protection such as Eaton MTL, Pepperl+Fuchs and Phoenix Contact. Based on the parameters and certification of conformity shown in the datasheets, the compliance of apparatuses and intrinsic safety loop can be examined. In this project, the conformity of four Ex i systems has been validated in terms of the compliance of the apparatuses and the intrinsic safety loop verification. The ways to implement the validation regarding the compliances of various apparatuses including temperature transducer, digital display, temperature sensors, solenoid valves and intrinsic safety barriers have been demonstrated. Furthermore, the proper way to utilize the energy curves in the verification of the safety parameters is covered. Apart from that, the intrinsic safety loop verification of several Ex i system configurations is executed. In addition, the flowcharts and equations are presented to interpret the intrinsic safety loop verification more understandably. In short, the conformity of all of the four Ex i systems is proven and the detailed steps of the verification are shown, thus providing clearer guidelines on the implementation of Ex i method as per IEC 60079-14. 2022 Final Year Project / Dissertation / Thesis NonPeerReviewed application/pdf http://eprints.utar.edu.my/5385/1/MH_1900592_Final_%2D_CHAM_YEONG_LIE_LESLIE.pdf Cham, Leslie Yeong Lie (2022) Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14. Final Year Project, UTAR. http://eprints.utar.edu.my/5385/
spellingShingle TJ Mechanical engineering and machinery
Cham, Leslie Yeong Lie
Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
title Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
title_full Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
title_fullStr Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
title_full_unstemmed Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
title_short Studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
title_sort studies on the explosion protection in hazardous area based on intrinsically safe method exi according to iec60079-14
topic TJ Mechanical engineering and machinery
url http://eprints.utar.edu.my/5385/
http://eprints.utar.edu.my/5385/1/MH_1900592_Final_%2D_CHAM_YEONG_LIE_LESLIE.pdf