Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C
| Main Author: | |
|---|---|
| Format: | Final Year Project / Dissertation / Thesis |
| Published: |
2015
|
| Subjects: | |
| Online Access: | http://eprints.utar.edu.my/2171/ http://eprints.utar.edu.my/2171/1/Christopher%2DThesis%2Dammeded_copy.pdf |
| _version_ | 1848885599160762368 |
|---|---|
| author | Lim, Christopher Yi-Jin |
| author_facet | Lim, Christopher Yi-Jin |
| author_sort | Lim, Christopher Yi-Jin |
| building | UTAR Institutional Repository |
| collection | Online Access |
| first_indexed | 2025-11-15T19:25:09Z |
| format | Final Year Project / Dissertation / Thesis |
| id | utar-2171 |
| institution | Universiti Tunku Abdul Rahman |
| institution_category | Local University |
| last_indexed | 2025-11-15T19:25:09Z |
| publishDate | 2015 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | utar-21712016-10-04T03:38:25Z Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C Lim, Christopher Yi-Jin TJ Mechanical engineering and machinery 2015 Final Year Project / Dissertation / Thesis NonPeerReviewed application/pdf http://eprints.utar.edu.my/2171/1/Christopher%2DThesis%2Dammeded_copy.pdf Lim, Christopher Yi-Jin (2015) Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C. Master dissertation/thesis, UTAR. http://eprints.utar.edu.my/2171/ |
| spellingShingle | TJ Mechanical engineering and machinery Lim, Christopher Yi-Jin Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C |
| title | Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C
|
| title_full | Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C
|
| title_fullStr | Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C
|
| title_full_unstemmed | Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C
|
| title_short | Comparative Performance Tests on Thermosyphons and Application as Heat Pipe Heat Exchanger Cooler Operating Between 30-100°C
|
| title_sort | comparative performance tests on thermosyphons and application as heat pipe heat exchanger cooler operating between 30-100°c |
| topic | TJ Mechanical engineering and machinery |
| url | http://eprints.utar.edu.my/2171/ http://eprints.utar.edu.my/2171/1/Christopher%2DThesis%2Dammeded_copy.pdf |