Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia

Introduction: Recognition of latent iron deficiency (LID) and thalassemia trait (TT) are challenging with the use of standard red blood cell (RBC) parameters. Accurate diagnosis is vital as the management of iron deficiency and haemoglobinopathy are different. The use of extended RBC parameters - re...

Full description

Bibliographic Details
Main Author: Sockalingam, Sivanesan
Format: Thesis
Language:English
Published: 2023
Subjects:
Online Access:http://eprints.usm.my/62766/
http://eprints.usm.my/62766/1/Sivanesan%20Sockalingam%20-%20E.pdf
_version_ 1848885083011809280
author Sockalingam, Sivanesan
author_facet Sockalingam, Sivanesan
author_sort Sockalingam, Sivanesan
building USM Institutional Repository
collection Online Access
description Introduction: Recognition of latent iron deficiency (LID) and thalassemia trait (TT) are challenging with the use of standard red blood cell (RBC) parameters. Accurate diagnosis is vital as the management of iron deficiency and haemoglobinopathy are different. The use of extended RBC parameters - reticulocyte haemoglobin equivalent (RET-He), percentage of microcytic RBC <60fL (MicroR), and percentage of hypochromic RBC <17pg (HYPO-He) may aid in the detection of LID and TT. The study aims to determine the diagnostic ability of these extended RBC parameters to distinguish LID and TT. Methodology: This was a prospective, case-control study conducted in Hospital USM from August 2021 to June 2022. 162 out of 212 blood donors who fulfilled the inclusion criteria were classified into the control group, LID group and TT group based on RBC parameters, serum ferritin and thalassaemia status. Between-group comparisons, receiver operating characteristic (ROC) curve analysis and comparison of area under the curve (AUC) for the RBC parameters were determined. The optimal cut-off was determined using the best Youden index. Result: There were 17 (10.5%) subjects with LID, 26 (16.0%) subjects with TT and 119 (73.5%) subjects in the control group. Standard RBC parameters were within the reference interval for all groups except for RBC (in females), MCV and MCH in the TT group. In LID and TT, RET-He and MicroR were lower and higher than the reference interval respectively, while HYPO-He was within the reference interval in all the groups. Taking into consideration the reference interval, RET-He was the best parameter to distinguish LID (AUC 0.723, 95% CI 0.608-0.839; 76.47% sensitivity and 73.95% specificity at 30.1pg cut-off) and TT (AUC 0.832, 95% CI 0.749-0.914; 84.62% sensitivity and 73.11% specificity at 30.2pg cut-off) from control. MicroR was the best parameter to distinguish TT from LID (AUC 0.742, 95% CI 0.591-0.893; 65.38% sensitivity and 76.47% specificity at 6.5% cut-off). Although the AUC of RET-He and MicroR were not significantly different in all the case comparisons, only MicroR was significantly higher in TT (median 9.1%, IQR 17.5) than LID (median 4.0%, IQR 6.1). Conclusion: Among the extended RBC parameters, RET-He was the best parameter for the detection of LID and TT, while MicroR performed well in differentiating TT from LID. These accessible parameters through modern automated haematology analyzers are low cost, with high throughput and rapid turn-around time can optimize the management of iron deficiency and thalassemia screening in the population.
first_indexed 2025-11-15T19:16:57Z
format Thesis
id usm-62766
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T19:16:57Z
publishDate 2023
recordtype eprints
repository_type Digital Repository
spelling usm-627662025-08-19T08:18:02Z http://eprints.usm.my/62766/ Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia Sockalingam, Sivanesan R Medicine RC31-1245 Internal medicine Introduction: Recognition of latent iron deficiency (LID) and thalassemia trait (TT) are challenging with the use of standard red blood cell (RBC) parameters. Accurate diagnosis is vital as the management of iron deficiency and haemoglobinopathy are different. The use of extended RBC parameters - reticulocyte haemoglobin equivalent (RET-He), percentage of microcytic RBC <60fL (MicroR), and percentage of hypochromic RBC <17pg (HYPO-He) may aid in the detection of LID and TT. The study aims to determine the diagnostic ability of these extended RBC parameters to distinguish LID and TT. Methodology: This was a prospective, case-control study conducted in Hospital USM from August 2021 to June 2022. 162 out of 212 blood donors who fulfilled the inclusion criteria were classified into the control group, LID group and TT group based on RBC parameters, serum ferritin and thalassaemia status. Between-group comparisons, receiver operating characteristic (ROC) curve analysis and comparison of area under the curve (AUC) for the RBC parameters were determined. The optimal cut-off was determined using the best Youden index. Result: There were 17 (10.5%) subjects with LID, 26 (16.0%) subjects with TT and 119 (73.5%) subjects in the control group. Standard RBC parameters were within the reference interval for all groups except for RBC (in females), MCV and MCH in the TT group. In LID and TT, RET-He and MicroR were lower and higher than the reference interval respectively, while HYPO-He was within the reference interval in all the groups. Taking into consideration the reference interval, RET-He was the best parameter to distinguish LID (AUC 0.723, 95% CI 0.608-0.839; 76.47% sensitivity and 73.95% specificity at 30.1pg cut-off) and TT (AUC 0.832, 95% CI 0.749-0.914; 84.62% sensitivity and 73.11% specificity at 30.2pg cut-off) from control. MicroR was the best parameter to distinguish TT from LID (AUC 0.742, 95% CI 0.591-0.893; 65.38% sensitivity and 76.47% specificity at 6.5% cut-off). Although the AUC of RET-He and MicroR were not significantly different in all the case comparisons, only MicroR was significantly higher in TT (median 9.1%, IQR 17.5) than LID (median 4.0%, IQR 6.1). Conclusion: Among the extended RBC parameters, RET-He was the best parameter for the detection of LID and TT, while MicroR performed well in differentiating TT from LID. These accessible parameters through modern automated haematology analyzers are low cost, with high throughput and rapid turn-around time can optimize the management of iron deficiency and thalassemia screening in the population. 2023 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/62766/1/Sivanesan%20Sockalingam%20-%20E.pdf Sockalingam, Sivanesan (2023) Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia. Masters thesis, Universiti Sains Malaysia.
spellingShingle R Medicine
RC31-1245 Internal medicine
Sockalingam, Sivanesan
Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia
title Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia
title_full Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia
title_fullStr Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia
title_full_unstemmed Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia
title_short Clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in Hospital Universiti Sains Malaysia
title_sort clinical utility of extended red blood cell parameters in the diagnosis of latent iron deficiency and thalassaemia trait in hospital universiti sains malaysia
topic R Medicine
RC31-1245 Internal medicine
url http://eprints.usm.my/62766/
http://eprints.usm.my/62766/1/Sivanesan%20Sockalingam%20-%20E.pdf