Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
Breast cancer is the most typical kind of cancer among women. Meanwhile, mammography is the most widely used and effective diagnostic technique for early detection of breast cancer. Since breast tissue is particularly sensitive to radiation, the mean glandular dose (MGD) is determined by utilizin...
| Main Author: | |
|---|---|
| Format: | Thesis |
| Language: | English |
| Published: |
2023
|
| Subjects: | |
| Online Access: | http://eprints.usm.my/60887/ http://eprints.usm.my/60887/1/ZEINAB%20AHMED%20SHAKER%20HEGIAN%20-%20TESIS24.pdf |
| _version_ | 1848884563232686080 |
|---|---|
| author | Hegian, Zeinab Ahmed Shaker |
| author_facet | Hegian, Zeinab Ahmed Shaker |
| author_sort | Hegian, Zeinab Ahmed Shaker |
| building | USM Institutional Repository |
| collection | Online Access |
| description | Breast cancer is the most typical kind of cancer among women. Meanwhile,
mammography is the most widely used and effective diagnostic technique for early
detection of breast cancer. Since breast tissue is particularly sensitive to radiation,
the mean glandular dose (MGD) is determined by utilizing several of the breast
screening-specific exposure radiation dose criteria. The patient can receive the least
amount of radiation possible with an image quality that allows for the visibility of
pathological findings. As a result, the Diagnostic Reference Level (DRL) was
established in order to provide optimum exposure parameters for assessing and
reducing patient radiation doses. Since no data on mammography radiation doses
exists in Jordan, this study focuses on preparing a preliminary set of data by
analysing patient dose, average glandular dose, and DRL within nine mammogram
units. The study comprised of 3600 data for patients aged 21 to 80 years old with a
Compressed Breast Thickness (CBT) of 16.9 mm to 156 mm. Finally, patient
radiation dose data was compared to other published studies in the literature. The
DRLs for the entire sample were calculated using the 75th and 95th percentiles of
the MGD variable. The DRL values in Jordan at the 75th and 95th percentiles are
2.03 mGy and 2.93 mGy, respectively. Following that, the DRLs values for four
different projections ((right craniocaudal (RCC) view, left craniocaudal (LCC) view,
right mediolateral oblique (RMLO) view, and left mediolateral oblique (LMLO)
view) are established in this study |
| first_indexed | 2025-11-15T19:08:41Z |
| format | Thesis |
| id | usm-60887 |
| institution | Universiti Sains Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T19:08:41Z |
| publishDate | 2023 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | usm-608872024-07-31T08:03:18Z http://eprints.usm.my/60887/ Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan Hegian, Zeinab Ahmed Shaker QC1 Physics (General) Breast cancer is the most typical kind of cancer among women. Meanwhile, mammography is the most widely used and effective diagnostic technique for early detection of breast cancer. Since breast tissue is particularly sensitive to radiation, the mean glandular dose (MGD) is determined by utilizing several of the breast screening-specific exposure radiation dose criteria. The patient can receive the least amount of radiation possible with an image quality that allows for the visibility of pathological findings. As a result, the Diagnostic Reference Level (DRL) was established in order to provide optimum exposure parameters for assessing and reducing patient radiation doses. Since no data on mammography radiation doses exists in Jordan, this study focuses on preparing a preliminary set of data by analysing patient dose, average glandular dose, and DRL within nine mammogram units. The study comprised of 3600 data for patients aged 21 to 80 years old with a Compressed Breast Thickness (CBT) of 16.9 mm to 156 mm. Finally, patient radiation dose data was compared to other published studies in the literature. The DRLs for the entire sample were calculated using the 75th and 95th percentiles of the MGD variable. The DRL values in Jordan at the 75th and 95th percentiles are 2.03 mGy and 2.93 mGy, respectively. Following that, the DRLs values for four different projections ((right craniocaudal (RCC) view, left craniocaudal (LCC) view, right mediolateral oblique (RMLO) view, and left mediolateral oblique (LMLO) view) are established in this study 2023-06 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/60887/1/ZEINAB%20AHMED%20SHAKER%20HEGIAN%20-%20TESIS24.pdf Hegian, Zeinab Ahmed Shaker (2023) Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan. Masters thesis, Universiti Sains Malaysia. |
| spellingShingle | QC1 Physics (General) Hegian, Zeinab Ahmed Shaker Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan |
| title | Evaluation Of The Radiation Dose For
Mammography In King Hussein Cancer
Center, Jordan |
| title_full | Evaluation Of The Radiation Dose For
Mammography In King Hussein Cancer
Center, Jordan |
| title_fullStr | Evaluation Of The Radiation Dose For
Mammography In King Hussein Cancer
Center, Jordan |
| title_full_unstemmed | Evaluation Of The Radiation Dose For
Mammography In King Hussein Cancer
Center, Jordan |
| title_short | Evaluation Of The Radiation Dose For
Mammography In King Hussein Cancer
Center, Jordan |
| title_sort | evaluation of the radiation dose for
mammography in king hussein cancer
center, jordan |
| topic | QC1 Physics (General) |
| url | http://eprints.usm.my/60887/ http://eprints.usm.my/60887/1/ZEINAB%20AHMED%20SHAKER%20HEGIAN%20-%20TESIS24.pdf |