Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan

Breast cancer is the most typical kind of cancer among women. Meanwhile, mammography is the most widely used and effective diagnostic technique for early detection of breast cancer. Since breast tissue is particularly sensitive to radiation, the mean glandular dose (MGD) is determined by utilizin...

Full description

Bibliographic Details
Main Author: Hegian, Zeinab Ahmed Shaker
Format: Thesis
Language:English
Published: 2023
Subjects:
Online Access:http://eprints.usm.my/60887/
http://eprints.usm.my/60887/1/ZEINAB%20AHMED%20SHAKER%20HEGIAN%20-%20TESIS24.pdf
_version_ 1848884563232686080
author Hegian, Zeinab Ahmed Shaker
author_facet Hegian, Zeinab Ahmed Shaker
author_sort Hegian, Zeinab Ahmed Shaker
building USM Institutional Repository
collection Online Access
description Breast cancer is the most typical kind of cancer among women. Meanwhile, mammography is the most widely used and effective diagnostic technique for early detection of breast cancer. Since breast tissue is particularly sensitive to radiation, the mean glandular dose (MGD) is determined by utilizing several of the breast screening-specific exposure radiation dose criteria. The patient can receive the least amount of radiation possible with an image quality that allows for the visibility of pathological findings. As a result, the Diagnostic Reference Level (DRL) was established in order to provide optimum exposure parameters for assessing and reducing patient radiation doses. Since no data on mammography radiation doses exists in Jordan, this study focuses on preparing a preliminary set of data by analysing patient dose, average glandular dose, and DRL within nine mammogram units. The study comprised of 3600 data for patients aged 21 to 80 years old with a Compressed Breast Thickness (CBT) of 16.9 mm to 156 mm. Finally, patient radiation dose data was compared to other published studies in the literature. The DRLs for the entire sample were calculated using the 75th and 95th percentiles of the MGD variable. The DRL values in Jordan at the 75th and 95th percentiles are 2.03 mGy and 2.93 mGy, respectively. Following that, the DRLs values for four different projections ((right craniocaudal (RCC) view, left craniocaudal (LCC) view, right mediolateral oblique (RMLO) view, and left mediolateral oblique (LMLO) view) are established in this study
first_indexed 2025-11-15T19:08:41Z
format Thesis
id usm-60887
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T19:08:41Z
publishDate 2023
recordtype eprints
repository_type Digital Repository
spelling usm-608872024-07-31T08:03:18Z http://eprints.usm.my/60887/ Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan Hegian, Zeinab Ahmed Shaker QC1 Physics (General) Breast cancer is the most typical kind of cancer among women. Meanwhile, mammography is the most widely used and effective diagnostic technique for early detection of breast cancer. Since breast tissue is particularly sensitive to radiation, the mean glandular dose (MGD) is determined by utilizing several of the breast screening-specific exposure radiation dose criteria. The patient can receive the least amount of radiation possible with an image quality that allows for the visibility of pathological findings. As a result, the Diagnostic Reference Level (DRL) was established in order to provide optimum exposure parameters for assessing and reducing patient radiation doses. Since no data on mammography radiation doses exists in Jordan, this study focuses on preparing a preliminary set of data by analysing patient dose, average glandular dose, and DRL within nine mammogram units. The study comprised of 3600 data for patients aged 21 to 80 years old with a Compressed Breast Thickness (CBT) of 16.9 mm to 156 mm. Finally, patient radiation dose data was compared to other published studies in the literature. The DRLs for the entire sample were calculated using the 75th and 95th percentiles of the MGD variable. The DRL values in Jordan at the 75th and 95th percentiles are 2.03 mGy and 2.93 mGy, respectively. Following that, the DRLs values for four different projections ((right craniocaudal (RCC) view, left craniocaudal (LCC) view, right mediolateral oblique (RMLO) view, and left mediolateral oblique (LMLO) view) are established in this study 2023-06 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/60887/1/ZEINAB%20AHMED%20SHAKER%20HEGIAN%20-%20TESIS24.pdf Hegian, Zeinab Ahmed Shaker (2023) Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan. Masters thesis, Universiti Sains Malaysia.
spellingShingle QC1 Physics (General)
Hegian, Zeinab Ahmed Shaker
Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
title Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
title_full Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
title_fullStr Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
title_full_unstemmed Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
title_short Evaluation Of The Radiation Dose For Mammography In King Hussein Cancer Center, Jordan
title_sort evaluation of the radiation dose for mammography in king hussein cancer center, jordan
topic QC1 Physics (General)
url http://eprints.usm.my/60887/
http://eprints.usm.my/60887/1/ZEINAB%20AHMED%20SHAKER%20HEGIAN%20-%20TESIS24.pdf