Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010

This study was conducted to assess occupants’ satisfaction with their surrounding temperature conditions. The study was carried out at three places which are students’ dormitory, residential and prayer hall of Pusat Islam Engineering Campus, USM. It entailed determining the compliance of thermal com...

Full description

Bibliographic Details
Main Author: Halili, Ummi Zulaikha Ahmad
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2021
Subjects:
Online Access:http://eprints.usm.my/57430/
http://eprints.usm.my/57430/1/Compliance%20Of%20Thermal%20Comfort%20Parameters%20Within%20Students%E2%80%99%20Dormitory%2C%20Residental%20And%20Pusat%20Islam%20Engineering%20Campus%2C%20Usm%20Based%20On%20Industry%20Code%20Of%20Practice%20On%20Indoor%20Air%20Quality%20%28Icop%29%202010.pdf
_version_ 1848883621414305792
author Halili, Ummi Zulaikha Ahmad
author_facet Halili, Ummi Zulaikha Ahmad
author_sort Halili, Ummi Zulaikha Ahmad
building USM Institutional Repository
collection Online Access
description This study was conducted to assess occupants’ satisfaction with their surrounding temperature conditions. The study was carried out at three places which are students’ dormitory, residential and prayer hall of Pusat Islam Engineering Campus, USM. It entailed determining the compliance of thermal comfort parameters; temperature, relative humidity and air movement. The parameters are then used as input in the Center for the Built Environment (CBE) Thermal Comfort Tool to obtain Predicted Mean Value and Predicted Percentage Dissatisfied for ASHRAE Standard-55. The monitoring for this study was conducted for three hours in a three-time period; 6 A.M. - 9 A.M., 11 A.M. - 2 P.M. and 5 P.M. - 8 P.M. for students’ dormitory and residential. For monitoring at Pusat Islam, it was conducted in two slots; 11 A.M. - 2 P.M. and 6 P.M. - 10 P.M., and it was assessed during Ramadan, where the Muslims perform Teraweh prayer. Overall, the finding indicates that most of the time, the thermal comfort parameters do not comply with the ICOP limit. This is due to the poor design of students’ dormitory where the plan itself does not promote cross-ventilation, causing discomfort towards the occupants.
first_indexed 2025-11-15T18:53:43Z
format Monograph
id usm-57430
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:53:43Z
publishDate 2021
publisher Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-574302023-03-17T08:09:21Z http://eprints.usm.my/57430/ Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010 Halili, Ummi Zulaikha Ahmad T Technology TA1-2040 Engineering (General). Civil engineering (General) This study was conducted to assess occupants’ satisfaction with their surrounding temperature conditions. The study was carried out at three places which are students’ dormitory, residential and prayer hall of Pusat Islam Engineering Campus, USM. It entailed determining the compliance of thermal comfort parameters; temperature, relative humidity and air movement. The parameters are then used as input in the Center for the Built Environment (CBE) Thermal Comfort Tool to obtain Predicted Mean Value and Predicted Percentage Dissatisfied for ASHRAE Standard-55. The monitoring for this study was conducted for three hours in a three-time period; 6 A.M. - 9 A.M., 11 A.M. - 2 P.M. and 5 P.M. - 8 P.M. for students’ dormitory and residential. For monitoring at Pusat Islam, it was conducted in two slots; 11 A.M. - 2 P.M. and 6 P.M. - 10 P.M., and it was assessed during Ramadan, where the Muslims perform Teraweh prayer. Overall, the finding indicates that most of the time, the thermal comfort parameters do not comply with the ICOP limit. This is due to the poor design of students’ dormitory where the plan itself does not promote cross-ventilation, causing discomfort towards the occupants. Universiti Sains Malaysia 2021-08-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57430/1/Compliance%20Of%20Thermal%20Comfort%20Parameters%20Within%20Students%E2%80%99%20Dormitory%2C%20Residental%20And%20Pusat%20Islam%20Engineering%20Campus%2C%20Usm%20Based%20On%20Industry%20Code%20Of%20Practice%20On%20Indoor%20Air%20Quality%20%28Icop%29%202010.pdf Halili, Ummi Zulaikha Ahmad (2021) Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted)
spellingShingle T Technology
TA1-2040 Engineering (General). Civil engineering (General)
Halili, Ummi Zulaikha Ahmad
Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010
title Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010
title_full Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010
title_fullStr Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010
title_full_unstemmed Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010
title_short Compliance Of Thermal Comfort Parameters Within Students’ Dormitory, Residental And Pusat Islam Engineering Campus, Usm Based On Industry Code Of Practice On Indoor Air Quality (Icop) 2010
title_sort compliance of thermal comfort parameters within students’ dormitory, residental and pusat islam engineering campus, usm based on industry code of practice on indoor air quality (icop) 2010
topic T Technology
TA1-2040 Engineering (General). Civil engineering (General)
url http://eprints.usm.my/57430/
http://eprints.usm.my/57430/1/Compliance%20Of%20Thermal%20Comfort%20Parameters%20Within%20Students%E2%80%99%20Dormitory%2C%20Residental%20And%20Pusat%20Islam%20Engineering%20Campus%2C%20Usm%20Based%20On%20Industry%20Code%20Of%20Practice%20On%20Indoor%20Air%20Quality%20%28Icop%29%202010.pdf