Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode
Storage tanks are containers that hold liquids, compressed gases, or mediums used for the short or long-term storage of heat or cold. The tanks can be constructed vertically and horizontally, above ground, semi-underground, and underground, carry static and dynamic loads, under vacuum or overpressur...
| Main Author: | |
|---|---|
| Format: | Monograph |
| Language: | English |
| Published: |
Universiti Sains Malaysia
2021
|
| Subjects: | |
| Online Access: | http://eprints.usm.my/57377/ http://eprints.usm.my/57377/1/Analysis%20Of%20The%20Rectangular%20And%20Circular%20Cylindrical%20Rc%20Elevated%20Water%20Tank%20Design%20According%20To%20Eurocode.pdf |
| _version_ | 1848883606392406016 |
|---|---|
| author | Tee, Deng Wang |
| author_facet | Tee, Deng Wang |
| author_sort | Tee, Deng Wang |
| building | USM Institutional Repository |
| collection | Online Access |
| description | Storage tanks are containers that hold liquids, compressed gases, or mediums used for the short or long-term storage of heat or cold. The tanks can be constructed vertically and horizontally, above ground, semi-underground, and underground, carry static and dynamic loads, under vacuum or overpressure, wind, seismic, and temperature influences. In this project, the elevated tank is designed as a circular cylindrical shape elevated water tank and a rectangular shape. The differences between the reinforcement steel and the volume of concrete will be compared between the two designs. The design parameters considered are as described in the Eurocodes. some variables were considered in the design of an elevated water tank which are the thickness of the wall, the thickness of the base and roof, the depth of the tank, the height of the supporting tower. The wind loads are determined using finite element methods. To assist in design, the ETABS software is applied to design the two elevated water tanks. It was found that the circular cylindrical shape is more stable than the rectangular shape by modelling the model in Etabs with and without wind condition. However, the cost of circular cylindrical shape is 39.47 % more than the rectangular shape tanks.. |
| first_indexed | 2025-11-15T18:53:29Z |
| format | Monograph |
| id | usm-57377 |
| institution | Universiti Sains Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T18:53:29Z |
| publishDate | 2021 |
| publisher | Universiti Sains Malaysia |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | usm-573772023-03-16T03:49:56Z http://eprints.usm.my/57377/ Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode Tee, Deng Wang T Technology TA1-2040 Engineering (General). Civil engineering (General) Storage tanks are containers that hold liquids, compressed gases, or mediums used for the short or long-term storage of heat or cold. The tanks can be constructed vertically and horizontally, above ground, semi-underground, and underground, carry static and dynamic loads, under vacuum or overpressure, wind, seismic, and temperature influences. In this project, the elevated tank is designed as a circular cylindrical shape elevated water tank and a rectangular shape. The differences between the reinforcement steel and the volume of concrete will be compared between the two designs. The design parameters considered are as described in the Eurocodes. some variables were considered in the design of an elevated water tank which are the thickness of the wall, the thickness of the base and roof, the depth of the tank, the height of the supporting tower. The wind loads are determined using finite element methods. To assist in design, the ETABS software is applied to design the two elevated water tanks. It was found that the circular cylindrical shape is more stable than the rectangular shape by modelling the model in Etabs with and without wind condition. However, the cost of circular cylindrical shape is 39.47 % more than the rectangular shape tanks.. Universiti Sains Malaysia 2021-08-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57377/1/Analysis%20Of%20The%20Rectangular%20And%20Circular%20Cylindrical%20Rc%20Elevated%20Water%20Tank%20Design%20According%20To%20Eurocode.pdf Tee, Deng Wang (2021) Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted) |
| spellingShingle | T Technology TA1-2040 Engineering (General). Civil engineering (General) Tee, Deng Wang Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode |
| title | Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode |
| title_full | Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode |
| title_fullStr | Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode |
| title_full_unstemmed | Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode |
| title_short | Analysis Of The Rectangular And Circular Cylindrical Rc Elevated Water Tank Design According To Eurocode |
| title_sort | analysis of the rectangular and circular cylindrical rc elevated water tank design according to eurocode |
| topic | T Technology TA1-2040 Engineering (General). Civil engineering (General) |
| url | http://eprints.usm.my/57377/ http://eprints.usm.my/57377/1/Analysis%20Of%20The%20Rectangular%20And%20Circular%20Cylindrical%20Rc%20Elevated%20Water%20Tank%20Design%20According%20To%20Eurocode.pdf |