An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load

The study of effects on wind loading to the roof cladding and purlin connection become the focus of the present study. It is found that the failure of roof cladding initiated at the overhang roof due to turbulence created form the strong wind. However, the previous studies are limited to the non-eng...

Full description

Bibliographic Details
Main Author: Abdullah, Fatin Huwaina
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2021
Subjects:
Online Access:http://eprints.usm.my/56849/
http://eprints.usm.my/56849/1/An%20Experimental%20Investigation%20On%20The%20Performance%20Of%20The%20Modified%20Connection%20Of%20Overhang%20Roof%20Steel%20Cladding%20Subjected%20To%20Static%20Load.pdf
_version_ 1848883466096082944
author Abdullah, Fatin Huwaina
author_facet Abdullah, Fatin Huwaina
author_sort Abdullah, Fatin Huwaina
building USM Institutional Repository
collection Online Access
description The study of effects on wind loading to the roof cladding and purlin connection become the focus of the present study. It is found that the failure of roof cladding initiated at the overhang roof due to turbulence created form the strong wind. However, the previous studies are limited to the non-engineered building without overhang roof mainly the rural house in northern region of Peninsular Malaysia. In this study, the typical overhang roof length was obtained through rural house survey. The experimental study using simple pull-through, and pull-out test was performed to simulate the wind loading effect on rural house features especially at overhang roof. Therefore, the study is conducted to investigate the pull-through and pull-out capacity on cladding to purlin connection of rural house. The tests were conducted on two types of claddings namely, corrugated and trapezoidal roof cladding. The purlin used timber type Dark Red Meranti which classified under strength group 6 and the wind loading was applied via hydraulic jack machine. In the experimental work, two different thickness of cladding is used, which is 0.18 mm for corrugated steel cladding and 0.23 mm for trapezoidal steel cladding. The specimen is built with different types of assembly, namely control sample, modification 1, with the addition of roof cladding strap and modification 2, with the addition of roof cladding strap and small size wood. Based on the result from the experimental work, it can be identified that both specimen in modification 1 and 2 are having higher value of maximum load cell nail, 2.10 kN and 2.304 kN compared to 0.94 kN and 1.138 kN from control sample and maximum applied load, 4.91 kN and 6.367 kN compared to 2.74 kN and 2.804 kN from control sample for corrugated and trapezoidal roof cladding. Therefore, it can be concluded that the modification in the roof connection can increase its strength.
first_indexed 2025-11-15T18:51:15Z
format Monograph
id usm-56849
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:51:15Z
publishDate 2021
publisher Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-568492023-02-08T08:40:33Z http://eprints.usm.my/56849/ An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load Abdullah, Fatin Huwaina T Technology TA1-2040 Engineering (General). Civil engineering (General) The study of effects on wind loading to the roof cladding and purlin connection become the focus of the present study. It is found that the failure of roof cladding initiated at the overhang roof due to turbulence created form the strong wind. However, the previous studies are limited to the non-engineered building without overhang roof mainly the rural house in northern region of Peninsular Malaysia. In this study, the typical overhang roof length was obtained through rural house survey. The experimental study using simple pull-through, and pull-out test was performed to simulate the wind loading effect on rural house features especially at overhang roof. Therefore, the study is conducted to investigate the pull-through and pull-out capacity on cladding to purlin connection of rural house. The tests were conducted on two types of claddings namely, corrugated and trapezoidal roof cladding. The purlin used timber type Dark Red Meranti which classified under strength group 6 and the wind loading was applied via hydraulic jack machine. In the experimental work, two different thickness of cladding is used, which is 0.18 mm for corrugated steel cladding and 0.23 mm for trapezoidal steel cladding. The specimen is built with different types of assembly, namely control sample, modification 1, with the addition of roof cladding strap and modification 2, with the addition of roof cladding strap and small size wood. Based on the result from the experimental work, it can be identified that both specimen in modification 1 and 2 are having higher value of maximum load cell nail, 2.10 kN and 2.304 kN compared to 0.94 kN and 1.138 kN from control sample and maximum applied load, 4.91 kN and 6.367 kN compared to 2.74 kN and 2.804 kN from control sample for corrugated and trapezoidal roof cladding. Therefore, it can be concluded that the modification in the roof connection can increase its strength. Universiti Sains Malaysia 2021-08-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/56849/1/An%20Experimental%20Investigation%20On%20The%20Performance%20Of%20The%20Modified%20Connection%20Of%20Overhang%20Roof%20Steel%20Cladding%20Subjected%20To%20Static%20Load.pdf Abdullah, Fatin Huwaina (2021) An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted)
spellingShingle T Technology
TA1-2040 Engineering (General). Civil engineering (General)
Abdullah, Fatin Huwaina
An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load
title An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load
title_full An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load
title_fullStr An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load
title_full_unstemmed An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load
title_short An Experimental Investigation On The Performance Of The Modified Connection Of Overhang Roof Steel Cladding Subjected To Static Load
title_sort experimental investigation on the performance of the modified connection of overhang roof steel cladding subjected to static load
topic T Technology
TA1-2040 Engineering (General). Civil engineering (General)
url http://eprints.usm.my/56849/
http://eprints.usm.my/56849/1/An%20Experimental%20Investigation%20On%20The%20Performance%20Of%20The%20Modified%20Connection%20Of%20Overhang%20Roof%20Steel%20Cladding%20Subjected%20To%20Static%20Load.pdf