Study on the effects of patient miscentring on radiation dose and image quality in CT imaging

Incorrect setting of patient positioning on the treatment table always happened in diagnostic imaging which leads to misinterpretation of data and degrades the image quality. This study focuses to evaluate the effects of patient miscentring on patient dose and image quality in CT imaging. The CT...

Full description

Bibliographic Details
Main Author: Teo, Siti Humairah Mohd Razlan
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.usm.my/54238/
http://eprints.usm.my/54238/1/Siti%20Humairah-24%20pages.pdf
_version_ 1848882748498903040
author Teo, Siti Humairah Mohd Razlan
author_facet Teo, Siti Humairah Mohd Razlan
author_sort Teo, Siti Humairah Mohd Razlan
building USM Institutional Repository
collection Online Access
description Incorrect setting of patient positioning on the treatment table always happened in diagnostic imaging which leads to misinterpretation of data and degrades the image quality. This study focuses to evaluate the effects of patient miscentring on patient dose and image quality in CT imaging. The CT scan parameter, patient positioning information was taken from the head and thorax-abdomen-pelvic protocols acquired in 128-slice Siemens SOMATOM Definition AS + CT system. This study started with the retrospective survey on patient miscentring shifting data by using data registration (DoseWatch, version 1.2, GE Healthcare) to collect information about patient isocenter shifting. The range of miscentring for minimum and maximum had been obtained and will be used as guidelines in phantom studies. CTDI phantom and water phantom were used in dose measurement and image quality assessment respectively. CTDIw is used to calculate the dose across FOV of the phantom. In this study, isocentre shifting of both axes (positive or negative axis) can cause an increase or a decrease of CTDIw across the FOV. This research showed that the shift x- and y- axes and the phantom dose (CTDIw) have weak correlation which is 0.1796 and -0.2127 respectively for the 16cm CTDI phantom. While for 32 cm, the correlation is -0.3555 (weak) and 0.5582 (strong) between both variables. In image quality assessment, SNR is observed. Miscentring of both axes also associated with the quality of the image produced. There is no correlation between x-axis shifting and SNR (r = -0.0267). However, the correlation between mean HU and mean SD with the shift x-axis is weak. There is a strong positive association between the y-axis shifting and the SNR (r = 0.8156). The correlation between mean HU and mean SD also good with the y-axis.
first_indexed 2025-11-15T18:39:51Z
format Thesis
id usm-54238
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:39:51Z
publishDate 2020
recordtype eprints
repository_type Digital Repository
spelling usm-542382022-08-23T03:44:23Z http://eprints.usm.my/54238/ Study on the effects of patient miscentring on radiation dose and image quality in CT imaging Teo, Siti Humairah Mohd Razlan R Medicine Incorrect setting of patient positioning on the treatment table always happened in diagnostic imaging which leads to misinterpretation of data and degrades the image quality. This study focuses to evaluate the effects of patient miscentring on patient dose and image quality in CT imaging. The CT scan parameter, patient positioning information was taken from the head and thorax-abdomen-pelvic protocols acquired in 128-slice Siemens SOMATOM Definition AS + CT system. This study started with the retrospective survey on patient miscentring shifting data by using data registration (DoseWatch, version 1.2, GE Healthcare) to collect information about patient isocenter shifting. The range of miscentring for minimum and maximum had been obtained and will be used as guidelines in phantom studies. CTDI phantom and water phantom were used in dose measurement and image quality assessment respectively. CTDIw is used to calculate the dose across FOV of the phantom. In this study, isocentre shifting of both axes (positive or negative axis) can cause an increase or a decrease of CTDIw across the FOV. This research showed that the shift x- and y- axes and the phantom dose (CTDIw) have weak correlation which is 0.1796 and -0.2127 respectively for the 16cm CTDI phantom. While for 32 cm, the correlation is -0.3555 (weak) and 0.5582 (strong) between both variables. In image quality assessment, SNR is observed. Miscentring of both axes also associated with the quality of the image produced. There is no correlation between x-axis shifting and SNR (r = -0.0267). However, the correlation between mean HU and mean SD with the shift x-axis is weak. There is a strong positive association between the y-axis shifting and the SNR (r = 0.8156). The correlation between mean HU and mean SD also good with the y-axis. 2020-08 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/54238/1/Siti%20Humairah-24%20pages.pdf Teo, Siti Humairah Mohd Razlan (2020) Study on the effects of patient miscentring on radiation dose and image quality in CT imaging. Masters thesis, Universiti Sains Malaysia.
spellingShingle R Medicine
Teo, Siti Humairah Mohd Razlan
Study on the effects of patient miscentring on radiation dose and image quality in CT imaging
title Study on the effects of patient miscentring on radiation dose and image quality in CT imaging
title_full Study on the effects of patient miscentring on radiation dose and image quality in CT imaging
title_fullStr Study on the effects of patient miscentring on radiation dose and image quality in CT imaging
title_full_unstemmed Study on the effects of patient miscentring on radiation dose and image quality in CT imaging
title_short Study on the effects of patient miscentring on radiation dose and image quality in CT imaging
title_sort study on the effects of patient miscentring on radiation dose and image quality in ct imaging
topic R Medicine
url http://eprints.usm.my/54238/
http://eprints.usm.my/54238/1/Siti%20Humairah-24%20pages.pdf