Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid

For heterogeneous mixture, there are some separation techniques can be used to separate the mixture into individual component. For example, centrifugation, filtration and also adsorption. Adsorption is the most efficient and cost effective methods compared to other separation techniques. Magnetic se...

Full description

Bibliographic Details
Main Author: Ong, Yi Qian
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2018
Subjects:
Online Access:http://eprints.usm.my/53781/
http://eprints.usm.my/53781/1/Magnetophoresis%20Induced%20Hydrodynamic%20Flow%20Of%20Non-Newtonian%20Fluid_Ong%20Yi%20Qian_K4_2018.pdf
_version_ 1848882623244402688
author Ong, Yi Qian
author_facet Ong, Yi Qian
author_sort Ong, Yi Qian
building USM Institutional Repository
collection Online Access
description For heterogeneous mixture, there are some separation techniques can be used to separate the mixture into individual component. For example, centrifugation, filtration and also adsorption. Adsorption is the most efficient and cost effective methods compared to other separation techniques. Magnetic separation by using magnetic nanoparticles is one of the adsorption methods and is gaining more popularity among other techniques. However, when the size of the materials involved are reduced to nano size, the particles behavior in terms of flow, mixing and other phenomena will be different with macroscopic materials. This makes the reason to analyze and investigate the nanoparticles behavior and the interaction involved when the nanoparticles are inside the fluid medium. Low gradient magnetic separation is used to investigate the hydrodynamic flow of the particles when the aggregation parameter is fixed at below unity. The main focus in this research is the hydrodynamic effect in non-Newtonian. The magnetic Grashof number calculated for MNPs solution in Newtonian fluid is greater than in non-Newtonian fluid. This indicates that the magnetic buoyancy and also the fluid convection in Newtonian fluid significant is more significant than that in non- Newtonian fluid.
first_indexed 2025-11-15T18:37:51Z
format Monograph
id usm-53781
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:37:51Z
publishDate 2018
publisher Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-537812022-08-02T08:37:02Z http://eprints.usm.my/53781/ Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid Ong, Yi Qian T Technology TP Chemical Technology For heterogeneous mixture, there are some separation techniques can be used to separate the mixture into individual component. For example, centrifugation, filtration and also adsorption. Adsorption is the most efficient and cost effective methods compared to other separation techniques. Magnetic separation by using magnetic nanoparticles is one of the adsorption methods and is gaining more popularity among other techniques. However, when the size of the materials involved are reduced to nano size, the particles behavior in terms of flow, mixing and other phenomena will be different with macroscopic materials. This makes the reason to analyze and investigate the nanoparticles behavior and the interaction involved when the nanoparticles are inside the fluid medium. Low gradient magnetic separation is used to investigate the hydrodynamic flow of the particles when the aggregation parameter is fixed at below unity. The main focus in this research is the hydrodynamic effect in non-Newtonian. The magnetic Grashof number calculated for MNPs solution in Newtonian fluid is greater than in non-Newtonian fluid. This indicates that the magnetic buoyancy and also the fluid convection in Newtonian fluid significant is more significant than that in non- Newtonian fluid. Universiti Sains Malaysia 2018-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/53781/1/Magnetophoresis%20Induced%20Hydrodynamic%20Flow%20Of%20Non-Newtonian%20Fluid_Ong%20Yi%20Qian_K4_2018.pdf Ong, Yi Qian (2018) Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Kimia. (Submitted)
spellingShingle T Technology
TP Chemical Technology
Ong, Yi Qian
Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid
title Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid
title_full Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid
title_fullStr Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid
title_full_unstemmed Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid
title_short Magnetophoresis Induced Hydrodynamic Flow Of Non-Newtonian Fluid
title_sort magnetophoresis induced hydrodynamic flow of non-newtonian fluid
topic T Technology
TP Chemical Technology
url http://eprints.usm.my/53781/
http://eprints.usm.my/53781/1/Magnetophoresis%20Induced%20Hydrodynamic%20Flow%20Of%20Non-Newtonian%20Fluid_Ong%20Yi%20Qian_K4_2018.pdf