Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm

The main focus of this research is to propose and establish the local diagnostic reference levels (LDRLs) for the most frequent CT examinations performed at Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Penang, Malaysia. A total of 1444 CT examinations from January 2...

Full description

Bibliographic Details
Main Author: Razali, Mohd Amir Syahmi Mat
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://eprints.usm.my/52060/
http://eprints.usm.my/52060/1/MOHD%20AMIR%20SYAHMI%20BIN%20MAT%20RAZALI.pdf
_version_ 1848882156079677440
author Razali, Mohd Amir Syahmi Mat
author_facet Razali, Mohd Amir Syahmi Mat
author_sort Razali, Mohd Amir Syahmi Mat
building USM Institutional Repository
collection Online Access
description The main focus of this research is to propose and establish the local diagnostic reference levels (LDRLs) for the most frequent CT examinations performed at Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Penang, Malaysia. A total of 1444 CT examinations from January 2015 until December 2018 were included in a retrospective CT dose survey. Based on CT examination protocols, the proposed LDRLs were established at 50th (achievable dose, AD) and 75th (DRLs) percentile of CT dose index distribution which are CTDIvol, CTDIw, and dose length product, DLP. Comparison between established LDRLs with the national DRLs (NDRLs) from Ministry of Health (MOH) Malaysia and other recent international DRLs were performed, respectively. The most frequent CT examinations performed at AMDI were thorax-abdomen-pelvis (TAP) CT (46.95 %), trailed by pelvis CT (15.44 %), abdomen-pelvis (AP) CT (10.46 %), and brain CT (8.31 %). Most of the LDRLs surpassed the NDRLs and other recent international DRLs. From the radiation dose audit, most of the 2018 CT dose data exceeded the LDRLs; TAP, pelvis, AP, brain, and abdomen CT examinations were noted to have higher CT dose data. There were no significant differences (P-values = > 0.05) between most of 2018 CT data that exceed and below the proposed LDRLs. The main factors that contribute to higher dose were due to higher number of CT sequences, higher tube current (mAs) settings, and error in patient positioning. The LDRLs must be established to reduce unjustified radiation exposure incidence and to optimise the CT dose to the patients. For improvement of current local practice, the local dose distribution must always be revised regularly.
first_indexed 2025-11-15T18:30:26Z
format Thesis
id usm-52060
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:30:26Z
publishDate 2021
recordtype eprints
repository_type Digital Repository
spelling usm-520602022-03-28T07:58:45Z http://eprints.usm.my/52060/ Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm Razali, Mohd Amir Syahmi Mat RK1-715 Dentistry The main focus of this research is to propose and establish the local diagnostic reference levels (LDRLs) for the most frequent CT examinations performed at Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Penang, Malaysia. A total of 1444 CT examinations from January 2015 until December 2018 were included in a retrospective CT dose survey. Based on CT examination protocols, the proposed LDRLs were established at 50th (achievable dose, AD) and 75th (DRLs) percentile of CT dose index distribution which are CTDIvol, CTDIw, and dose length product, DLP. Comparison between established LDRLs with the national DRLs (NDRLs) from Ministry of Health (MOH) Malaysia and other recent international DRLs were performed, respectively. The most frequent CT examinations performed at AMDI were thorax-abdomen-pelvis (TAP) CT (46.95 %), trailed by pelvis CT (15.44 %), abdomen-pelvis (AP) CT (10.46 %), and brain CT (8.31 %). Most of the LDRLs surpassed the NDRLs and other recent international DRLs. From the radiation dose audit, most of the 2018 CT dose data exceeded the LDRLs; TAP, pelvis, AP, brain, and abdomen CT examinations were noted to have higher CT dose data. There were no significant differences (P-values = > 0.05) between most of 2018 CT data that exceed and below the proposed LDRLs. The main factors that contribute to higher dose were due to higher number of CT sequences, higher tube current (mAs) settings, and error in patient positioning. The LDRLs must be established to reduce unjustified radiation exposure incidence and to optimise the CT dose to the patients. For improvement of current local practice, the local dose distribution must always be revised regularly. 2021-05 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/52060/1/MOHD%20AMIR%20SYAHMI%20BIN%20MAT%20RAZALI.pdf Razali, Mohd Amir Syahmi Mat (2021) Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm. Masters thesis, Perpustakaan Hamzah Sendut.
spellingShingle RK1-715 Dentistry
Razali, Mohd Amir Syahmi Mat
Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm
title Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm
title_full Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm
title_fullStr Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm
title_full_unstemmed Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm
title_short Establishment Of Local Diagnostic Reference Levels (Drls) For Ct Examination And Assessment On Current Clinical Ct Practice At Amdi, Usm
title_sort establishment of local diagnostic reference levels (drls) for ct examination and assessment on current clinical ct practice at amdi, usm
topic RK1-715 Dentistry
url http://eprints.usm.my/52060/
http://eprints.usm.my/52060/1/MOHD%20AMIR%20SYAHMI%20BIN%20MAT%20RAZALI.pdf