Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System

Cold formed C-column have been used in interior wall construction. Because of the issue of material cost become one of the factors need to be considered in affordable house construction, the construction sector has introduced the concept of opening to the column web. Besides, this study focus on the...

Full description

Bibliographic Details
Main Author: Mustafa, Zafira Nur Ezzati
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2017
Subjects:
Online Access:http://eprints.usm.my/51809/
http://eprints.usm.my/51809/1/Buckling%20Capacity%20Of%20Cold-Formed%20Steel%20Structure%20Column%20Member%20With%20Perforation%20Section%20In%20Affordable%20House%20Framing%20System_Zafira%20Nur%20Ezzati%20Mustafa_A9_2017.pdf
_version_ 1848882086048432128
author Mustafa, Zafira Nur Ezzati
author_facet Mustafa, Zafira Nur Ezzati
author_sort Mustafa, Zafira Nur Ezzati
building USM Institutional Repository
collection Online Access
description Cold formed C-column have been used in interior wall construction. Because of the issue of material cost become one of the factors need to be considered in affordable house construction, the construction sector has introduced the concept of opening to the column web. Besides, this study focus on the buckling capacity for C-column cold formed steel with perforation. This study starts with determining the suitable spacing for the space column for the affordable house. Analysis house frame has been done in STAAD Pro. analysis using C-column without perforation. Opening with circular shape has been used in this study with the size of 0.4D, 0.6D and 0.8D (D=180mm). Spacing within the opening is 150mm, 250mm and 350mm. for the specimen with 0.4D opening and the edge distance is 539mm have the highest buckling capacity (26.59 kN). Reduction of buckling capacity is 5.31% from C-column without perforation and reduction of volume is -2.16%. for the same case with 0.8D opening, the buckling capacity reduce with 22.52% and volume is -6.85%. the conclusion of this study, C-column without perforation have higher buckling capacity compare to C-column with perforations.
first_indexed 2025-11-15T18:29:19Z
format Monograph
id usm-51809
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:29:19Z
publishDate 2017
publisher Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-518092022-03-03T08:33:11Z http://eprints.usm.my/51809/ Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System Mustafa, Zafira Nur Ezzati T Technology TA Engineering (General). Civil engineering (General) Cold formed C-column have been used in interior wall construction. Because of the issue of material cost become one of the factors need to be considered in affordable house construction, the construction sector has introduced the concept of opening to the column web. Besides, this study focus on the buckling capacity for C-column cold formed steel with perforation. This study starts with determining the suitable spacing for the space column for the affordable house. Analysis house frame has been done in STAAD Pro. analysis using C-column without perforation. Opening with circular shape has been used in this study with the size of 0.4D, 0.6D and 0.8D (D=180mm). Spacing within the opening is 150mm, 250mm and 350mm. for the specimen with 0.4D opening and the edge distance is 539mm have the highest buckling capacity (26.59 kN). Reduction of buckling capacity is 5.31% from C-column without perforation and reduction of volume is -2.16%. for the same case with 0.8D opening, the buckling capacity reduce with 22.52% and volume is -6.85%. the conclusion of this study, C-column without perforation have higher buckling capacity compare to C-column with perforations. Universiti Sains Malaysia 2017-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/51809/1/Buckling%20Capacity%20Of%20Cold-Formed%20Steel%20Structure%20Column%20Member%20With%20Perforation%20Section%20In%20Affordable%20House%20Framing%20System_Zafira%20Nur%20Ezzati%20Mustafa_A9_2017.pdf Mustafa, Zafira Nur Ezzati (2017) Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted)
spellingShingle T Technology
TA Engineering (General). Civil engineering (General)
Mustafa, Zafira Nur Ezzati
Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System
title Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System
title_full Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System
title_fullStr Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System
title_full_unstemmed Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System
title_short Buckling Capacity Of Cold-Formed Steel Structure Column Member With Perforation Section In Affordable House Framing System
title_sort buckling capacity of cold-formed steel structure column member with perforation section in affordable house framing system
topic T Technology
TA Engineering (General). Civil engineering (General)
url http://eprints.usm.my/51809/
http://eprints.usm.my/51809/1/Buckling%20Capacity%20Of%20Cold-Formed%20Steel%20Structure%20Column%20Member%20With%20Perforation%20Section%20In%20Affordable%20House%20Framing%20System_Zafira%20Nur%20Ezzati%20Mustafa_A9_2017.pdf