Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis

The determination of nickel in the chocolate was performed by Differential Pulse Cathodic Stripping Analysis(DPCSV). Chocolate was a complex sample with a high content of organic compounds such as sugar, protein, fat, lecithin and many more and its analysis generally involves digestion procedures...

Full description

Bibliographic Details
Main Author: Mohammad Zairy Azren, Jainal@ Zainal
Format: Monograph
Language:English
Published: PPSP, Universiti Sains Malaysia 2007
Subjects:
Online Access:http://eprints.usm.my/50210/
http://eprints.usm.my/50210/1/MOHAMAD%20ZAIRY%20AZREN%20BIN%20JAINAL%40%20ZAINAL-%2024%20pages.pdf
_version_ 1848881660261564416
author Mohammad Zairy Azren, Jainal@ Zainal
author_facet Mohammad Zairy Azren, Jainal@ Zainal
author_sort Mohammad Zairy Azren, Jainal@ Zainal
building USM Institutional Repository
collection Online Access
description The determination of nickel in the chocolate was performed by Differential Pulse Cathodic Stripping Analysis(DPCSV). Chocolate was a complex sample with a high content of organic compounds such as sugar, protein, fat, lecithin and many more and its analysis generally involves digestion procedures that might include the risk of losses and/or contamination. Wet digestion by using concentrated nitric acid and 1:1 ratio of distilled water-hydrochloric acid on the sample was selected on this study because of its availability and low cost . Sample was then processed to the sample analysis stage. Prior to the sample analysis by DPCSV, the optimum pH for the supporting electrolyte, Britton-Robinson Buffer (BRB}, 0.04 M and optimum parameters for the analysis was determined. Optimum pH for the supporting electrolyte, BRB was pH 4. Initial potential, Ei of -0.68 V, final potential, Er of-1.15 V, scan rate of0.050 V/s, deposition potential of -1.4 V, equilibration time of 5 s and deposition time, tacc of 20 s were the optimized parameters used in this study. The validation of methodology was performed by plotting a calibration curve peak height, ip versus different concentrations of nickel (5 ppm) as the stock solution. A linear graph with the regression equation of Y= 0.820+ 23.322X, correlation coefficient of 0.966, standard deviation of 1.129, sensitivity of 23.322 nA/ppm and limit of detection of 0.145 ppm was obtained. 3 different brands of chocolate were analyzed. The results in all samples show absence of nickel.
first_indexed 2025-11-15T18:22:33Z
format Monograph
id usm-50210
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:22:33Z
publishDate 2007
publisher PPSP, Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-502102021-10-11T03:48:49Z http://eprints.usm.my/50210/ Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis Mohammad Zairy Azren, Jainal@ Zainal R Medicine (General) The determination of nickel in the chocolate was performed by Differential Pulse Cathodic Stripping Analysis(DPCSV). Chocolate was a complex sample with a high content of organic compounds such as sugar, protein, fat, lecithin and many more and its analysis generally involves digestion procedures that might include the risk of losses and/or contamination. Wet digestion by using concentrated nitric acid and 1:1 ratio of distilled water-hydrochloric acid on the sample was selected on this study because of its availability and low cost . Sample was then processed to the sample analysis stage. Prior to the sample analysis by DPCSV, the optimum pH for the supporting electrolyte, Britton-Robinson Buffer (BRB}, 0.04 M and optimum parameters for the analysis was determined. Optimum pH for the supporting electrolyte, BRB was pH 4. Initial potential, Ei of -0.68 V, final potential, Er of-1.15 V, scan rate of0.050 V/s, deposition potential of -1.4 V, equilibration time of 5 s and deposition time, tacc of 20 s were the optimized parameters used in this study. The validation of methodology was performed by plotting a calibration curve peak height, ip versus different concentrations of nickel (5 ppm) as the stock solution. A linear graph with the regression equation of Y= 0.820+ 23.322X, correlation coefficient of 0.966, standard deviation of 1.129, sensitivity of 23.322 nA/ppm and limit of detection of 0.145 ppm was obtained. 3 different brands of chocolate were analyzed. The results in all samples show absence of nickel. PPSP, Universiti Sains Malaysia 2007 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/50210/1/MOHAMAD%20ZAIRY%20AZREN%20BIN%20JAINAL%40%20ZAINAL-%2024%20pages.pdf Mohammad Zairy Azren, Jainal@ Zainal (2007) Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis. Other. PPSP, Universiti Sains Malaysia. (Submitted)
spellingShingle R Medicine (General)
Mohammad Zairy Azren, Jainal@ Zainal
Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_full Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_fullStr Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_full_unstemmed Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_short Voltammetric Determination of Nickel in Chocolate by Differential Pulse Cathodic Stripping Analysis
title_sort voltammetric determination of nickel in chocolate by differential pulse cathodic stripping analysis
topic R Medicine (General)
url http://eprints.usm.my/50210/
http://eprints.usm.my/50210/1/MOHAMAD%20ZAIRY%20AZREN%20BIN%20JAINAL%40%20ZAINAL-%2024%20pages.pdf