Voltammetric Determination of Cadmium in Infant Mllk

Among the various environmental pollutants, heavy metals like cadmium was considered the most important due to high stability for bioaccumulation they were extremely dangerous for all biological organisms and especially for humans. This is a great importance to analyze and quantify this toxic age...

Full description

Bibliographic Details
Main Author: Haznan, Hashim
Format: Monograph
Language:English
Published: PPSP, Universiti Sains Malaysia 2007
Subjects:
Online Access:http://eprints.usm.my/50144/
http://eprints.usm.my/50144/1/HASNAN%20BIN%20HASHIM%20-%2024%20pages.pdf
_version_ 1848881643270438912
author Haznan, Hashim
author_facet Haznan, Hashim
author_sort Haznan, Hashim
building USM Institutional Repository
collection Online Access
description Among the various environmental pollutants, heavy metals like cadmium was considered the most important due to high stability for bioaccumulation they were extremely dangerous for all biological organisms and especially for humans. This is a great importance to analyze and quantify this toxic agent in the environment. Various methods have been done such as atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) in determination of cadmium in matrix. Often these techniques require complex sample preparation and expensive instrumentation. In contrast, voltammetric methods particularly anodic stripping voltammetric (ASV) had some advantages such as little or no sample pretreatment is required, detection limit is as low as 1 o-10 M and low cost instrumentation. For this work, cadmium was studied in various brand of infant milk. Besides, aim of this work was to improve anodic stripping voltammetric (ASV) method for cadmium detection by optimizing voltammetric condition (pH) and voltammetric parameters such as initial potential (Ei), final potential (Er), scan rate (v), deposition potential (Eacc), deposition time (tacc). and equilibration time (feq) in ASV. The samples preparation was done by extraction using acid digestion and filtration using filter paper. The samples were analyzed under optimized voltammetric condition and parameters. Cadmium was not detected in any of studied under this project work.
first_indexed 2025-11-15T18:22:17Z
format Monograph
id usm-50144
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:22:17Z
publishDate 2007
publisher PPSP, Universiti Sains Malaysia
recordtype eprints
repository_type Digital Repository
spelling usm-501442021-10-05T07:53:29Z http://eprints.usm.my/50144/ Voltammetric Determination of Cadmium in Infant Mllk Haznan, Hashim R Medicine (General) Among the various environmental pollutants, heavy metals like cadmium was considered the most important due to high stability for bioaccumulation they were extremely dangerous for all biological organisms and especially for humans. This is a great importance to analyze and quantify this toxic agent in the environment. Various methods have been done such as atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) in determination of cadmium in matrix. Often these techniques require complex sample preparation and expensive instrumentation. In contrast, voltammetric methods particularly anodic stripping voltammetric (ASV) had some advantages such as little or no sample pretreatment is required, detection limit is as low as 1 o-10 M and low cost instrumentation. For this work, cadmium was studied in various brand of infant milk. Besides, aim of this work was to improve anodic stripping voltammetric (ASV) method for cadmium detection by optimizing voltammetric condition (pH) and voltammetric parameters such as initial potential (Ei), final potential (Er), scan rate (v), deposition potential (Eacc), deposition time (tacc). and equilibration time (feq) in ASV. The samples preparation was done by extraction using acid digestion and filtration using filter paper. The samples were analyzed under optimized voltammetric condition and parameters. Cadmium was not detected in any of studied under this project work. PPSP, Universiti Sains Malaysia 2007 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/50144/1/HASNAN%20BIN%20HASHIM%20-%2024%20pages.pdf Haznan, Hashim (2007) Voltammetric Determination of Cadmium in Infant Mllk. Other. PPSP, Universiti Sains Malaysia. (Submitted)
spellingShingle R Medicine (General)
Haznan, Hashim
Voltammetric Determination of Cadmium in Infant Mllk
title Voltammetric Determination of Cadmium in Infant Mllk
title_full Voltammetric Determination of Cadmium in Infant Mllk
title_fullStr Voltammetric Determination of Cadmium in Infant Mllk
title_full_unstemmed Voltammetric Determination of Cadmium in Infant Mllk
title_short Voltammetric Determination of Cadmium in Infant Mllk
title_sort voltammetric determination of cadmium in infant mllk
topic R Medicine (General)
url http://eprints.usm.my/50144/
http://eprints.usm.my/50144/1/HASNAN%20BIN%20HASHIM%20-%2024%20pages.pdf