Effect of pysical filters (aluminum 0.2mm and o.jmm thick) on sensitivity, uniformity, and spatial resolution of Toshiba GCA- 901A/HG gamma camera with tc-99m in planar imaging
The performance of a scintillation-camera system is assessed to assure the acquisition of diagnostically reliable images. Decisions-making data to determine acceptability of camera performance are acquired when some parameters are tested. So, in this study the sensitivity, uniformity and system s...
| Main Author: | Nawi, Siti Nazipah Mohamad |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia
2004
|
| Subjects: | |
| Online Access: | http://eprints.usm.my/46757/ http://eprints.usm.my/46757/1/PTA...Siti%20Nazipah%20Binti%20Mohamad%20Nawi...2004...-24%20pages.pdf |
Similar Items
Evaluation of toshiba gca-901a gamma camera performance by using a material filter (cu 0.125 mm) in tc-99m conventional imaging
by: Isa, Ismaliza
Published: (2004)
by: Isa, Ismaliza
Published: (2004)
Comparison of uptake
99mTcO4; 99mTc-DTPA and 99mTc-MDP by breast cancer cell line.
by: Rafzi, Siti Noraisyah
Published: (2015)
by: Rafzi, Siti Noraisyah
Published: (2015)
Investigations into the effects of material filters (Cu 0.125mm and Al 0.2mm) on image linearity in Tc-99m SPECT
by: Shah, Syed Inayatullah, et al.
Published: (2016)
by: Shah, Syed Inayatullah, et al.
Published: (2016)
Tc-99m NIDP and Tc-99m HMPAO labelled leukocyte scans in
tuberculous spondylitis
by: Mohamad, Abdul R, et al.
Published: (1999)
by: Mohamad, Abdul R, et al.
Published: (1999)
Effect of different thickness of material filter on Tc-99m spectra and performance parameters of gamma camera
by: Abdullah, Nazifah, et al.
Published: (2014)
by: Abdullah, Nazifah, et al.
Published: (2014)
Comparison of uptake 99mTcO4; 99mTc-dtpa and "mTc-mdp by breast cancer cell line.
by: Rafzi, Siti Noraisyah
Published: (2015)
by: Rafzi, Siti Noraisyah
Published: (2015)
Effects of unconventional (Material) filters on the quality of images produced by three Gamma camera systems in Tc-99m SPECT
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
Uniformity, sensitivity, linearity, and hot region image analysis by employing unconventional filter technique (Cu 0.125mm and AI 0.2mm) with Tc-99m inSPECT imaging
by: Vee, Fong Shu
Published: (2004)
by: Vee, Fong Shu
Published: (2004)
Short-term retention of 99mTc activity in bone scintigraphy
by: Ali, W. M., et al.
Published: (2021)
by: Ali, W. M., et al.
Published: (2021)
Utilisation of Backscattered Gamma Photons in Tc-99m SPECT Imaging
by: Sayed, Inayatullah Shah, et al.
Published: (1998)
by: Sayed, Inayatullah Shah, et al.
Published: (1998)
Image quality enhancement by reducing scattered gamma photons with a flat sheet of Zinc 0.35 mm thick material filter in Tc-99m SPECT
by: Sayed, Inayatullah Shah, et al.
Published: (2018)
by: Sayed, Inayatullah Shah, et al.
Published: (2018)
Effects of Copper 0.127 mm Thick Flat Sheet on Uniform and Hot Region Images as A Material Filter for Scatter Correction in Tc-99m SPECT
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
Performance improvement of local automotive industry by adopting JMM
by: Mohiuddin, A. K. M., et al.
Published: (2015)
by: Mohiuddin, A. K. M., et al.
Published: (2015)
Tc99m-sestamibi: pembangunan kit radiofarmaseutikal untuk pemetaan jantung
by: Wan Hamirul Bahrin W.K.,, et al.
Published: (2009)
by: Wan Hamirul Bahrin W.K.,, et al.
Published: (2009)
UPM receives Graduates’ Choice Award (GCA) 2023
by: Mohd Azhari, Nurul Ezzaty
Published: (2023)
by: Mohd Azhari, Nurul Ezzaty
Published: (2023)
UPM rangkul Anugerah Majikan Pilihan Graduan (GCA) 2023
by: Mohd Azhari, Nurul Ezzaty
Published: (2023)
by: Mohd Azhari, Nurul Ezzaty
Published: (2023)
UPM rangkul Anugerah Majikan Pilihan Graduan (GCA) 2023
by: Mohd Azhari, Nurul Ezzaty
Published: (2023)
by: Mohd Azhari, Nurul Ezzaty
Published: (2023)
Quantitative and qualitative studies of extrinsic and intrinsic uniformity on gamma camera detectors using co-57 flood source & tc-99m point source: experimental and clinical studies
by: Yuan, Koo Xing
Published: (2024)
by: Yuan, Koo Xing
Published: (2024)
The Study of Toshiba Singapore - Computer Systems Division (CSD) Information System
by: Tan, Sze Hui
Published: (2007)
by: Tan, Sze Hui
Published: (2007)
Interactions between anionic radionuclides (129I, 79Se and 99Tc) and soil geocolloids
by: Sanders, Heather K.
Published: (2018)
by: Sanders, Heather K.
Published: (2018)
A new technique for reduction of scattered Gamma photons in Tc-99m SPECT imaging
by: Sayed, Inayatullah Shah, et al.
Published: (2011)
by: Sayed, Inayatullah Shah, et al.
Published: (2011)
Flat sheet of zinc material as a filter for gamma photons in Tc-99m SPECT imaging
by: Abdullah, Nazifah, et al.
Published: (2018)
by: Abdullah, Nazifah, et al.
Published: (2018)
Scatter correction in Tc99m SPECT using effective attenuation coefficient and material filter technique
by: Sayed, Inayatullah Shah, et al.
Published: (2012)
by: Sayed, Inayatullah Shah, et al.
Published: (2012)
Adoption of JMM practices – A key to performance
improvement of a local automotive industry
by: Mohiuddin, A. K. M., et al.
Published: (2017)
by: Mohiuddin, A. K. M., et al.
Published: (2017)
Heterogeneous Preferences and Demand-Side Lifecycle Theory in Camera Industry: Take 35mm SLR and Medium Format Cameras as Examples
by: CHOU, YU-CHIEH
Published: (2012)
by: CHOU, YU-CHIEH
Published: (2012)
Use of an Effective Attenuation Coefficient Value and Material Filter Technique for Scatter Correction in Tc-99m SPECT
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
Impacts of Butterworth post-filtering on
absolute quantification of 99mTc SPECT/CT using nema phantom
by: Chi, Leah Tan Shin
Published: (2024)
by: Chi, Leah Tan Shin
Published: (2024)
Dynamic renal scintigraphy: technetium99m (Tc99m) diethylenetriaminepentaacetic Acid (DTPA), breast cancer center of International Islamic University Malaysia (IIUM) experience
by: Abdul Rahim, Mohamad Shahrir, et al.
Published: (2019)
by: Abdul Rahim, Mohamad Shahrir, et al.
Published: (2019)
OMEGA - OSIRIS mapping of emission-line galaxies in A901/2: III. - Galaxy properties across projected phase space in A901/2
by: Weinzirl, Tim, et al.
Published: (2017)
by: Weinzirl, Tim, et al.
Published: (2017)
Effect of cut-off frequency of butterworth filter on detectability and contrast of hot and cold regions in Tc-99m SPECT
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
by: Sayed, Inayatullah Shah, et al.
Published: (2016)
The role of PET/CT amyloid Imaging compared with Tc99m-HMPAO SPECT imaging for diagnosing Alzheimer's disease
by: Suppiah, Subapriya, et al.
Published: (2018)
by: Suppiah, Subapriya, et al.
Published: (2018)
Comparison of Chang’s with Sorenson’s attenuation correction method by varying linear attenuation coefficient values in Tc-99m SPECT imaging
by: Sayed, Inayatullah Shah, et al.
Published: (2008)
by: Sayed, Inayatullah Shah, et al.
Published: (2008)
Reconstruction of wide energy window data for hot and cold region images in TC99M single photon emission tomography
by: Shah, Sayed Inayatullah, et al.
Published: (1996)
by: Shah, Sayed Inayatullah, et al.
Published: (1996)
Estimating Gfr In Oncology Patients Receiving Cisplatin Chemotherapy : Predicted Creatinine Clearance Against Tc-99m Dtpa Methods
by: Syed Sahab, Sharifah Khaidah
Published: (2016)
by: Syed Sahab, Sharifah Khaidah
Published: (2016)
The effect of digital and physical filters on image quality for quantitative Tc-99m single photon emission computed tomography (SPECT).
by: Latiff, Rukiah A.
Published: (2010)
by: Latiff, Rukiah A.
Published: (2010)
Possibility of Hg redistribution in tridax procumbens due to Hg contamnination.
by: Chew, W., et al.
Published: (2011)
by: Chew, W., et al.
Published: (2011)
Tc-99m myocardial SPECT image quality improvement with a physical filter as scattered gamma photon absorber: phantom study
by: Sayed, Inayatullah Shah, et al.
Published: (2017)
by: Sayed, Inayatullah Shah, et al.
Published: (2017)
Cold and hot region detectability and image quality enhancement in Tc99m SPECT by reduction of scattered gamma photons prior to detection
by: Shah, Sayed Inayatullah, et al.
Published: (2011)
by: Shah, Sayed Inayatullah, et al.
Published: (2011)
Cold and hot region detectability and image quality enhancement in TC99m spect by reduction of scattered gamma photons prior to detectio
by: Sayed, Inayatullah Shah, et al.
Published: (2011)
by: Sayed, Inayatullah Shah, et al.
Published: (2011)
Myocardial Perfusion Imaging Using 99mTc-MIBI Single Photon Emission Computed Tomography: A Cardiac Phantom Study
by: Al Moudi, Mansour, et al.
Published: (2013)
by: Al Moudi, Mansour, et al.
Published: (2013)
Similar Items
-
Evaluation of toshiba gca-901a gamma camera performance by using a material filter (cu 0.125 mm) in tc-99m conventional imaging
by: Isa, Ismaliza
Published: (2004) -
Comparison of uptake
99mTcO4; 99mTc-DTPA and 99mTc-MDP by breast cancer cell line.
by: Rafzi, Siti Noraisyah
Published: (2015) -
Investigations into the effects of material filters (Cu 0.125mm and Al 0.2mm) on image linearity in Tc-99m SPECT
by: Shah, Syed Inayatullah, et al.
Published: (2016) -
Tc-99m NIDP and Tc-99m HMPAO labelled leukocyte scans in
tuberculous spondylitis
by: Mohamad, Abdul R, et al.
Published: (1999) -
Effect of different thickness of material filter on Tc-99m spectra and performance parameters of gamma camera
by: Abdullah, Nazifah, et al.
Published: (2014)