Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment

NiTi archwires are used widely during the early stage of orthodontic treatment due to its superelastic and biocompatibility properties. Even though the superelastic NiTi archwires are always preferred in most orthodontic treatments, the evolution of phase transformation and force-deflection behaviou...

Full description

Bibliographic Details
Main Author: Razali, Muhammad Fauzinizam
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.usm.my/46362/
http://eprints.usm.my/46362/1/Phase%20Transformation%20And%20Force-Deflection%20Responses%20Of%20Niti%20Archwire%20For%20Bracket%20Assembly%20In%20Orthodontic%20Treatment.pdf
_version_ 1848880587265277952
author Razali, Muhammad Fauzinizam
author_facet Razali, Muhammad Fauzinizam
author_sort Razali, Muhammad Fauzinizam
building USM Institutional Repository
collection Online Access
description NiTi archwires are used widely during the early stage of orthodontic treatment due to its superelastic and biocompatibility properties. Even though the superelastic NiTi archwires are always preferred in most orthodontic treatments, the evolution of phase transformation and force-deflection behaviour of this wire subjected to bend in the bracket system is still uncertain. Since changes in bending setting are frequently encountered during levelling, the extent of wire deformation and binding friction at the wire-bracket interface would alter the force-deflection behaviour and subsequently defies the optimal force criteria. This study investigated the evolution of phase transformation and forces released by NiTi archwire during orthodontic levelling treatment. For this purpose, a three-dimensional finite-element model of superelastic NiTi wire bends in three-bracket configurations was developed by employing a user material subroutine of superelasticity and contact interaction. The friction coefficient required to define the contact between the wire and stainless steel bracket was obtained from a sliding test. The competency of the bending model was examined by comparing the predicted force-deflection curve with the experimental results. The work further advanced the current knowledge on the influence of binding towards the force-deflection behaviour of NiTi wire by performing a quantitative study at two levelling conditions; bending at different levelling settings (inter-bracket distance, wire deflection and oral temperature) and bending with the presence of different bracket materials (friction coefficient at contact locations were varied from 0.1 to 0.5. During bending, only a small section of the wire length underwent austenite to martensite transformation, leaving the rest of the length substantially undeformed. The wire activated to 2.0 mm produced the maximum stress on the stress plateau, implying that the NiTi wire was deformed by stress-induced martensitic transformation. The wire activated to 3.0 mm and 4.0 mm essentially produced the maximum stress on the elastic line of martensite. The generation of binding at the bracket edges significantly elevated the maximum force and the slope of the deactivation curve, whilst diminished the minimum force values. The greatest binding of 8.33 N and 3.72 N was generated by the 0.40 × 0.56-mm and 0.4-mm archwires at the maximum deflection (4.0 mm) and temperature readings (46°C), and at the minimum inter-bracket distance (7.0 mm). For the case of large tooth displacement (4.0 mm), the 0.4-mm archwire delivered force in between 0.13 N to 0.73 N, which are within the optimal force range. The developed regression model can be used to predict the force-deflection of NiTi wire for the studied bracket system. Additionally, the archwires coupled with the ceramic brackets (≥ 0.4) produced zero force magnitude at the onset of the deactivation cycle, thus inhibited further tooth movement.
first_indexed 2025-11-15T18:05:30Z
format Thesis
id usm-46362
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:05:30Z
publishDate 2018
recordtype eprints
repository_type Digital Repository
spelling usm-463622021-11-17T03:42:14Z http://eprints.usm.my/46362/ Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment Razali, Muhammad Fauzinizam T Technology TP Chemical Technology NiTi archwires are used widely during the early stage of orthodontic treatment due to its superelastic and biocompatibility properties. Even though the superelastic NiTi archwires are always preferred in most orthodontic treatments, the evolution of phase transformation and force-deflection behaviour of this wire subjected to bend in the bracket system is still uncertain. Since changes in bending setting are frequently encountered during levelling, the extent of wire deformation and binding friction at the wire-bracket interface would alter the force-deflection behaviour and subsequently defies the optimal force criteria. This study investigated the evolution of phase transformation and forces released by NiTi archwire during orthodontic levelling treatment. For this purpose, a three-dimensional finite-element model of superelastic NiTi wire bends in three-bracket configurations was developed by employing a user material subroutine of superelasticity and contact interaction. The friction coefficient required to define the contact between the wire and stainless steel bracket was obtained from a sliding test. The competency of the bending model was examined by comparing the predicted force-deflection curve with the experimental results. The work further advanced the current knowledge on the influence of binding towards the force-deflection behaviour of NiTi wire by performing a quantitative study at two levelling conditions; bending at different levelling settings (inter-bracket distance, wire deflection and oral temperature) and bending with the presence of different bracket materials (friction coefficient at contact locations were varied from 0.1 to 0.5. During bending, only a small section of the wire length underwent austenite to martensite transformation, leaving the rest of the length substantially undeformed. The wire activated to 2.0 mm produced the maximum stress on the stress plateau, implying that the NiTi wire was deformed by stress-induced martensitic transformation. The wire activated to 3.0 mm and 4.0 mm essentially produced the maximum stress on the elastic line of martensite. The generation of binding at the bracket edges significantly elevated the maximum force and the slope of the deactivation curve, whilst diminished the minimum force values. The greatest binding of 8.33 N and 3.72 N was generated by the 0.40 × 0.56-mm and 0.4-mm archwires at the maximum deflection (4.0 mm) and temperature readings (46°C), and at the minimum inter-bracket distance (7.0 mm). For the case of large tooth displacement (4.0 mm), the 0.4-mm archwire delivered force in between 0.13 N to 0.73 N, which are within the optimal force range. The developed regression model can be used to predict the force-deflection of NiTi wire for the studied bracket system. Additionally, the archwires coupled with the ceramic brackets (≥ 0.4) produced zero force magnitude at the onset of the deactivation cycle, thus inhibited further tooth movement. 2018-01-01 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/46362/1/Phase%20Transformation%20And%20Force-Deflection%20Responses%20Of%20Niti%20Archwire%20For%20Bracket%20Assembly%20In%20Orthodontic%20Treatment.pdf Razali, Muhammad Fauzinizam (2018) Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment. PhD thesis, Universiti Sains Malaysia.
spellingShingle T Technology
TP Chemical Technology
Razali, Muhammad Fauzinizam
Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment
title Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment
title_full Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment
title_fullStr Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment
title_full_unstemmed Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment
title_short Phase Transformation And Force-Deflection Responses Of Niti Archwire For Bracket Assembly In Orthodontic Treatment
title_sort phase transformation and force-deflection responses of niti archwire for bracket assembly in orthodontic treatment
topic T Technology
TP Chemical Technology
url http://eprints.usm.my/46362/
http://eprints.usm.my/46362/1/Phase%20Transformation%20And%20Force-Deflection%20Responses%20Of%20Niti%20Archwire%20For%20Bracket%20Assembly%20In%20Orthodontic%20Treatment.pdf