A Novel Approach In Large Signal Power Line Communication

The main aim of this research is to identify and introduce a novel stand-alone and robust method for monitoring and control of a remote application. Among the three common techniques using fibre optic transmission layer, Supervisory Control And Data Acquisition (SCADA) and Power Line Communication (...

Full description

Bibliographic Details
Main Author: Nazem, Alireza
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.usm.my/46030/
http://eprints.usm.my/46030/1/Alireza%20Nazem24.pdf
_version_ 1848880493128318976
author Nazem, Alireza
author_facet Nazem, Alireza
author_sort Nazem, Alireza
building USM Institutional Repository
collection Online Access
description The main aim of this research is to identify and introduce a novel stand-alone and robust method for monitoring and control of a remote application. Among the three common techniques using fibre optic transmission layer, Supervisory Control And Data Acquisition (SCADA) and Power Line Communication (PLC). PLC method will result in minimizing the cabling usage. However, this technique will be unable to carry reliable information for long distance without the repeater facilities. In fibre-optic technique, although the attenuation of an optical transmission through a fibre layer is considerably low it will normally require additional electrical conductivity for transmission of power. Moreover, a hybrid cable, which consists of multiple physical fibre and copper layers, is irreparable in case of any damage during deployment and the cost of replacing such cables is often relatively high. While, A SCADA system will need both repeater facilities and additional power cable for remote applications. In order to overcome these problems, the Frequency and Amplitude Modulations Power Line Communication (FAMPLC) technique is proposed. FAMPLC, in general, provides a narrowband communication platform which consists of a Frequency Modulated Power Supply (FMPS) and Thevenin Equivalent Converter (TEC) block at the server side and the PWM reader and an active resistance as a dummy load at the receiver side. FMPS is a power gateway, as well as the large signal carrier for the Frequency Modulation (FM), to transmit the combination of the supplying voltage and the informative data as PWM.
first_indexed 2025-11-15T18:04:00Z
format Thesis
id usm-46030
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:04:00Z
publishDate 2014
recordtype eprints
repository_type Digital Repository
spelling usm-460302020-01-30T02:02:15Z http://eprints.usm.my/46030/ A Novel Approach In Large Signal Power Line Communication Nazem, Alireza TK1-9971 Electrical engineering. Electronics. Nuclear engineering The main aim of this research is to identify and introduce a novel stand-alone and robust method for monitoring and control of a remote application. Among the three common techniques using fibre optic transmission layer, Supervisory Control And Data Acquisition (SCADA) and Power Line Communication (PLC). PLC method will result in minimizing the cabling usage. However, this technique will be unable to carry reliable information for long distance without the repeater facilities. In fibre-optic technique, although the attenuation of an optical transmission through a fibre layer is considerably low it will normally require additional electrical conductivity for transmission of power. Moreover, a hybrid cable, which consists of multiple physical fibre and copper layers, is irreparable in case of any damage during deployment and the cost of replacing such cables is often relatively high. While, A SCADA system will need both repeater facilities and additional power cable for remote applications. In order to overcome these problems, the Frequency and Amplitude Modulations Power Line Communication (FAMPLC) technique is proposed. FAMPLC, in general, provides a narrowband communication platform which consists of a Frequency Modulated Power Supply (FMPS) and Thevenin Equivalent Converter (TEC) block at the server side and the PWM reader and an active resistance as a dummy load at the receiver side. FMPS is a power gateway, as well as the large signal carrier for the Frequency Modulation (FM), to transmit the combination of the supplying voltage and the informative data as PWM. 2014-01 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/46030/1/Alireza%20Nazem24.pdf Nazem, Alireza (2014) A Novel Approach In Large Signal Power Line Communication. PhD thesis, Universiti Sains Malaysia.
spellingShingle TK1-9971 Electrical engineering. Electronics. Nuclear engineering
Nazem, Alireza
A Novel Approach In Large Signal Power Line Communication
title A Novel Approach In Large Signal Power Line Communication
title_full A Novel Approach In Large Signal Power Line Communication
title_fullStr A Novel Approach In Large Signal Power Line Communication
title_full_unstemmed A Novel Approach In Large Signal Power Line Communication
title_short A Novel Approach In Large Signal Power Line Communication
title_sort novel approach in large signal power line communication
topic TK1-9971 Electrical engineering. Electronics. Nuclear engineering
url http://eprints.usm.my/46030/
http://eprints.usm.my/46030/1/Alireza%20Nazem24.pdf