Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings

The excessive usage of air-conditioning to cool internal room in a building for human thermal comfort is harming our planet due to their hazardous refrigerants and the high energy consumption nature of these cooling systems. Hence replacement of these systems with the Peltier Cooling Device (P...

Full description

Bibliographic Details
Main Author: Seifi, Molood
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.usm.my/45151/
http://eprints.usm.my/45151/1/Molood%20Seifi24.pdf
_version_ 1848880247258218496
author Seifi, Molood
author_facet Seifi, Molood
author_sort Seifi, Molood
building USM Institutional Repository
collection Online Access
description The excessive usage of air-conditioning to cool internal room in a building for human thermal comfort is harming our planet due to their hazardous refrigerants and the high energy consumption nature of these cooling systems. Hence replacement of these systems with the Peltier Cooling Device (PCDs) which are more environmental friendly is highly encouraged. However, the application of PCDs in Buildings has remained minimal as they have limited cooling capacities that reduces the ability of the device in generating cooling effect and causing temperature reduction in enclosed spaces. Thus the present study seeks to improve the temperature reduction by the Peltier Cooling Device through an appropriate application strategy so that they can be used for reducing the temperature of buildings internal spaces. The data analysis of physical experiments revealed that there is a temperature reduction improvement of 0.75-0.78 °C by each PCD operating on the internal room when the overall building temperature is dropped by 5 °C in the application strategy two (AS2). Hence this strategy is the appropriate one to enhance the ability of the device in reducing the temperature reduction of the internal room. Moreover the Malaysian thermal comfort (MTC) for each cubic meter of the building internal spaces could be fulfilled with one to five modules of PCDs in normal room temperature up to 32 ° C; while the MTC can be achieved for internal spaces of higher temperature range 33 ° C – 37 ° C when the overall room temperature is dropped by 5 ° C with the assistance of any type of cooling system, likewise the application strategy two.
first_indexed 2025-11-15T18:00:05Z
format Thesis
id usm-45151
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T18:00:05Z
publishDate 2013
recordtype eprints
repository_type Digital Repository
spelling usm-451512019-08-01T08:53:25Z http://eprints.usm.my/45151/ Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings Seifi, Molood TH1-9745 Building construction The excessive usage of air-conditioning to cool internal room in a building for human thermal comfort is harming our planet due to their hazardous refrigerants and the high energy consumption nature of these cooling systems. Hence replacement of these systems with the Peltier Cooling Device (PCDs) which are more environmental friendly is highly encouraged. However, the application of PCDs in Buildings has remained minimal as they have limited cooling capacities that reduces the ability of the device in generating cooling effect and causing temperature reduction in enclosed spaces. Thus the present study seeks to improve the temperature reduction by the Peltier Cooling Device through an appropriate application strategy so that they can be used for reducing the temperature of buildings internal spaces. The data analysis of physical experiments revealed that there is a temperature reduction improvement of 0.75-0.78 °C by each PCD operating on the internal room when the overall building temperature is dropped by 5 °C in the application strategy two (AS2). Hence this strategy is the appropriate one to enhance the ability of the device in reducing the temperature reduction of the internal room. Moreover the Malaysian thermal comfort (MTC) for each cubic meter of the building internal spaces could be fulfilled with one to five modules of PCDs in normal room temperature up to 32 ° C; while the MTC can be achieved for internal spaces of higher temperature range 33 ° C – 37 ° C when the overall room temperature is dropped by 5 ° C with the assistance of any type of cooling system, likewise the application strategy two. 2013-07 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/45151/1/Molood%20Seifi24.pdf Seifi, Molood (2013) Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings. Masters thesis, Universiti Sains Malaysia.
spellingShingle TH1-9745 Building construction
Seifi, Molood
Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_full Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_fullStr Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_full_unstemmed Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_short Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_sort effectiveness of peltier cooling device in reducing the air temperature of rooms in buildings
topic TH1-9745 Building construction
url http://eprints.usm.my/45151/
http://eprints.usm.my/45151/1/Molood%20Seifi24.pdf