Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group

Two types of memristor sensor were fabricated using two different TiO2 deposition methods of sputtering and sol-gel spin coating. The surface morphology of the sensors and the behaviour of the sensors were analysed by using scanning electron microscopy with energy dispersive x-ray system and I-V c...

Full description

Bibliographic Details
Main Authors: Hadis, Nor Shahanim Mohamad, Manaf, Asrulnizam Abd, Ngalim, Siti Hawa, Herman, Sukreen Hana
Format: Article
Published: Elsevier 2017
Subjects:
Online Access:http://eprints.usm.my/36958/
_version_ 1848878056596307968
author Hadis, Nor Shahanim Mohamad
Manaf, Asrulnizam Abd
Ngalim, Siti Hawa
Herman, Sukreen Hana
author_facet Hadis, Nor Shahanim Mohamad
Manaf, Asrulnizam Abd
Ngalim, Siti Hawa
Herman, Sukreen Hana
author_sort Hadis, Nor Shahanim Mohamad
building USM Institutional Repository
collection Online Access
description Two types of memristor sensor were fabricated using two different TiO2 deposition methods of sputtering and sol-gel spin coating. The surface morphology of the sensors and the behaviour of the sensors were analysed by using scanning electron microscopy with energy dispersive x-ray system and I-V characterisation system respectively. The sensors were applied with liquid with hydroxyl group to check the capability of this sensor in sensing different concentration of hydroxyl ion inside the liquid. For that purpose, D-glucose liquid with four concentrations of 10 mM, 20 mM, 30 mM and 40 mM were chosen. The liquids dispensed onto the TiO2 surface to act as sensing material. The TiO2 surface was initially covered with polydimethylsiloxane to control the liquid. The sensing capability of the sensors was determined via the current-voltage measurement and off-on resistance ratio. The sensitivity of the sensors was analysed from the off-on resistance ratio analysis. Type II memristor sensor which was fabricated using sol-gel spin coating technique recorded high sensitivity of 120.65 (mM)−1, while Type I sensor fabricated using the sputtering technique recorded low sensitivity of 0.035 (mM)−1. However, SEM-EDX image illustrated that the sputtering technique produced more uniform TiO2 thin film than sol-gel spin coating technique with larger atomic number of oxygen through the sol-gel spin coating technique. This indicates Type II sensor that has large number of oxygen atom produced more reaction with hydroxyl ion inside the liquid. While, Type I sensor produced less reaction compared with Type II and thus produced smaller off-on resistance ratio.
first_indexed 2025-11-15T17:25:16Z
format Article
id usm-36958
institution Universiti Sains Malaysia
institution_category Local University
last_indexed 2025-11-15T17:25:16Z
publishDate 2017
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling usm-369582018-02-12T08:08:49Z http://eprints.usm.my/36958/ Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group Hadis, Nor Shahanim Mohamad Manaf, Asrulnizam Abd Ngalim, Siti Hawa Herman, Sukreen Hana RK1-715 Dentistry TK1-9971 Electrical engineering. Electronics. Nuclear engineering Two types of memristor sensor were fabricated using two different TiO2 deposition methods of sputtering and sol-gel spin coating. The surface morphology of the sensors and the behaviour of the sensors were analysed by using scanning electron microscopy with energy dispersive x-ray system and I-V characterisation system respectively. The sensors were applied with liquid with hydroxyl group to check the capability of this sensor in sensing different concentration of hydroxyl ion inside the liquid. For that purpose, D-glucose liquid with four concentrations of 10 mM, 20 mM, 30 mM and 40 mM were chosen. The liquids dispensed onto the TiO2 surface to act as sensing material. The TiO2 surface was initially covered with polydimethylsiloxane to control the liquid. The sensing capability of the sensors was determined via the current-voltage measurement and off-on resistance ratio. The sensitivity of the sensors was analysed from the off-on resistance ratio analysis. Type II memristor sensor which was fabricated using sol-gel spin coating technique recorded high sensitivity of 120.65 (mM)−1, while Type I sensor fabricated using the sputtering technique recorded low sensitivity of 0.035 (mM)−1. However, SEM-EDX image illustrated that the sputtering technique produced more uniform TiO2 thin film than sol-gel spin coating technique with larger atomic number of oxygen through the sol-gel spin coating technique. This indicates Type II sensor that has large number of oxygen atom produced more reaction with hydroxyl ion inside the liquid. While, Type I sensor produced less reaction compared with Type II and thus produced smaller off-on resistance ratio. Elsevier 2017-06 Article PeerReviewed Hadis, Nor Shahanim Mohamad and Manaf, Asrulnizam Abd and Ngalim, Siti Hawa and Herman, Sukreen Hana (2017) Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group. Sensing and Bio-Sensing Research, 14. pp. 21-29. ISSN 2214-1804 http://dx.doi.org/10.1016/j.sbsr.2017.04.002
spellingShingle RK1-715 Dentistry
TK1-9971 Electrical engineering. Electronics. Nuclear engineering
Hadis, Nor Shahanim Mohamad
Manaf, Asrulnizam Abd
Ngalim, Siti Hawa
Herman, Sukreen Hana
Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
title Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
title_full Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
title_fullStr Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
title_full_unstemmed Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
title_short Fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
title_sort fabrication and characterisation of fluidic based memristor sensor for liquid with hydroxyl group
topic RK1-715 Dentistry
TK1-9971 Electrical engineering. Electronics. Nuclear engineering
url http://eprints.usm.my/36958/
http://eprints.usm.my/36958/