Analysis and design of multi-storey composite building

Many types of multistory buildings are the symbols of modernized and developed nations. These buildings are the solution to the problem of living because of population growth. High-rise steel frame and concrete frame structures have been constructed in design of tall buildings in our country as a...

Full description

Bibliographic Details
Main Authors: Tin, Nann, Tin , Tin Win
Format: Conference or Workshop Item
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.usm.my/34429/
http://eprints.usm.my/34429/1/HBP8.pdf
_version_ 1848877339996323840
author Tin, Nann
Tin , Tin Win
author_facet Tin, Nann
Tin , Tin Win
author_sort Tin, Nann
building USM Institutional Repository
collection Online Access
description Many types of multistory buildings are the symbols of modernized and developed nations. These buildings are the solution to the problem of living because of population growth. High-rise steel frame and concrete frame structures have been constructed in design of tall buildings in our country as a standard role. But, composite tall building is not situated up to now. Therefore, it is necessary to study special attention in designing the composite tall building. This study deals with composite action in structural members of 5 stories composite building. It belongs to seismic zone 2A. The spans of the sample model are arranged from 10 feet to 30 feet. Analysis of building is carried out by using ETABS Software. In designing beam members, ETABS Software is also used, but CSICOL Software is introduced for column design. Only square sections are used in column design for the purpose of easy to construct the building. The structure is composed of special moment resisting frame by using steel and concrete materials. Seismic load follows the Uniform Building Code (UBC) procedure of equivalent static and dynamic analysis load assumptions and load combinations are also according to UBC provision. In dynamic analysis, response spectrum method is used. Wide flange W-sections are used for frame members associated with reinforced concrete. Floor slabs are designed as metal steel deck supporting concrete slab system. Joints are considered as rigid joints and connection is designed with bolts and weld. Necessary checking is carried out for the stability of the superstructure.
first_indexed 2025-11-15T17:13:53Z
format Conference or Workshop Item
id usm-34429
institution Universiti Sains Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T17:13:53Z
publishDate 2008
recordtype eprints
repository_type Digital Repository
spelling usm-344292017-05-22T07:21:28Z http://eprints.usm.my/34429/ Analysis and design of multi-storey composite building Tin, Nann Tin , Tin Win TH1-9745 Building construction Many types of multistory buildings are the symbols of modernized and developed nations. These buildings are the solution to the problem of living because of population growth. High-rise steel frame and concrete frame structures have been constructed in design of tall buildings in our country as a standard role. But, composite tall building is not situated up to now. Therefore, it is necessary to study special attention in designing the composite tall building. This study deals with composite action in structural members of 5 stories composite building. It belongs to seismic zone 2A. The spans of the sample model are arranged from 10 feet to 30 feet. Analysis of building is carried out by using ETABS Software. In designing beam members, ETABS Software is also used, but CSICOL Software is introduced for column design. Only square sections are used in column design for the purpose of easy to construct the building. The structure is composed of special moment resisting frame by using steel and concrete materials. Seismic load follows the Uniform Building Code (UBC) procedure of equivalent static and dynamic analysis load assumptions and load combinations are also according to UBC provision. In dynamic analysis, response spectrum method is used. Wide flange W-sections are used for frame members associated with reinforced concrete. Floor slabs are designed as metal steel deck supporting concrete slab system. Joints are considered as rigid joints and connection is designed with bolts and weld. Necessary checking is carried out for the stability of the superstructure. 2008-12 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.usm.my/34429/1/HBP8.pdf Tin, Nann and Tin , Tin Win (2008) Analysis and design of multi-storey composite building. In: 2nd International Conference on Built Environment in Developing Countries., 3rd- 4th December 2008, Universiti Sains Malaysia, Pulau Pinang.
spellingShingle TH1-9745 Building construction
Tin, Nann
Tin , Tin Win
Analysis and design of multi-storey composite building
title Analysis and design of multi-storey composite building
title_full Analysis and design of multi-storey composite building
title_fullStr Analysis and design of multi-storey composite building
title_full_unstemmed Analysis and design of multi-storey composite building
title_short Analysis and design of multi-storey composite building
title_sort analysis and design of multi-storey composite building
topic TH1-9745 Building construction
url http://eprints.usm.my/34429/