Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study

The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Health...

Full description

Bibliographic Details
Main Authors: Muhammad, Nor Azura, Kayun, Zunaide, Abu Hassan, Hasyma, Hsiu, Jeannie Ding Wong, Kwan, Hoong Ng, Abdul Karim, Muhammad Khalis
Format: Article
Language:English
Published: Multidisciplinary Digital Publishing Institute 2021
Online Access:http://psasir.upm.edu.my/id/eprint/97164/
http://psasir.upm.edu.my/id/eprint/97164/1/ABSTRACT.pdf
_version_ 1848862530685894656
author Muhammad, Nor Azura
Kayun, Zunaide
Abu Hassan, Hasyma
Hsiu, Jeannie Ding Wong
Kwan, Hoong Ng
Abdul Karim, Muhammad Khalis
author_facet Muhammad, Nor Azura
Kayun, Zunaide
Abu Hassan, Hasyma
Hsiu, Jeannie Ding Wong
Kwan, Hoong Ng
Abdul Karim, Muhammad Khalis
author_sort Muhammad, Nor Azura
building UPM Institutional Repository
collection Online Access
description The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1–P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics.
first_indexed 2025-11-15T13:18:30Z
format Article
id upm-97164
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T13:18:30Z
publishDate 2021
publisher Multidisciplinary Digital Publishing Institute
recordtype eprints
repository_type Digital Repository
spelling upm-971642022-09-13T07:18:54Z http://psasir.upm.edu.my/id/eprint/97164/ Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study Muhammad, Nor Azura Kayun, Zunaide Abu Hassan, Hasyma Hsiu, Jeannie Ding Wong Kwan, Hoong Ng Abdul Karim, Muhammad Khalis The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1–P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics. Multidisciplinary Digital Publishing Institute 2021 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/97164/1/ABSTRACT.pdf Muhammad, Nor Azura and Kayun, Zunaide and Abu Hassan, Hasyma and Hsiu, Jeannie Ding Wong and Kwan, Hoong Ng and Abdul Karim, Muhammad Khalis (2021) Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study. Applied Sciences, 11 (5). art. no. 2047. pp. 1-13. ISSN 2076-3417 https://www.mdpi.com/2076-3417/11/5/2047 10.3390/app11052047
spellingShingle Muhammad, Nor Azura
Kayun, Zunaide
Abu Hassan, Hasyma
Hsiu, Jeannie Ding Wong
Kwan, Hoong Ng
Abdul Karim, Muhammad Khalis
Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study
title Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study
title_full Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study
title_fullStr Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study
title_full_unstemmed Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study
title_short Evaluation of organ dose and image quality metrics of pediatric CT Chest-Abdomen-Pelvis (CAP) examination: an anthropomorphic phantom study
title_sort evaluation of organ dose and image quality metrics of pediatric ct chest-abdomen-pelvis (cap) examination: an anthropomorphic phantom study
url http://psasir.upm.edu.my/id/eprint/97164/
http://psasir.upm.edu.my/id/eprint/97164/
http://psasir.upm.edu.my/id/eprint/97164/
http://psasir.upm.edu.my/id/eprint/97164/1/ABSTRACT.pdf