Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces

Electrochemical characterization and detection of protonated dibucaine (DIC+) at microinterface array across water|1,6-dichlorohexane were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Some thermodynamic parameters of dibucaine, such as the standard transfer poten...

Full description

Bibliographic Details
Main Authors: Almbrok Abdulla, Eissa Mohamed, Yusof, Nor Azah, Abdullah, Jaafar, Mohd Zawawi, Ruzniza
Format: Article
Language:English
Published: Multidisciplinary Digital Publishing Institute 2021
Online Access:http://psasir.upm.edu.my/id/eprint/97051/
http://psasir.upm.edu.my/id/eprint/97051/1/ABSTRACT.pdf
_version_ 1848862504556429312
author Almbrok Abdulla, Eissa Mohamed
Yusof, Nor Azah
Abdullah, Jaafar
Mohd Zawawi, Ruzniza
author_facet Almbrok Abdulla, Eissa Mohamed
Yusof, Nor Azah
Abdullah, Jaafar
Mohd Zawawi, Ruzniza
author_sort Almbrok Abdulla, Eissa Mohamed
building UPM Institutional Repository
collection Online Access
description Electrochemical characterization and detection of protonated dibucaine (DIC+) at microinterface array across water|1,6-dichlorohexane were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Some thermodynamic parameters of dibucaine, such as the standard transfer potential, the Gibbs energy of transfer and the partition coefficient, were estimated by CV. In addition to the analytical parameters, the impact of bovine serum albumin (BSA) on dibucaine detection (in artificial serum matrices) was also investigated. DPV was applied to detect a lower concentration of DIC+, resulting in a detection limit of 0.9 ± 0.06 µM. While the presence of BSA affected CV, demonstrated as reduced current responses, DPV was confirmed to be an efficient method for lowering concentrations of the dibucaine detection in the artificial serum matrix in the presence of BSA, with a limit of detection (LOD) of 1.9 ± 0.12 µM.
first_indexed 2025-11-15T13:18:05Z
format Article
id upm-97051
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T13:18:05Z
publishDate 2021
publisher Multidisciplinary Digital Publishing Institute
recordtype eprints
repository_type Digital Repository
spelling upm-970512022-10-17T01:12:46Z http://psasir.upm.edu.my/id/eprint/97051/ Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces Almbrok Abdulla, Eissa Mohamed Yusof, Nor Azah Abdullah, Jaafar Mohd Zawawi, Ruzniza Electrochemical characterization and detection of protonated dibucaine (DIC+) at microinterface array across water|1,6-dichlorohexane were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Some thermodynamic parameters of dibucaine, such as the standard transfer potential, the Gibbs energy of transfer and the partition coefficient, were estimated by CV. In addition to the analytical parameters, the impact of bovine serum albumin (BSA) on dibucaine detection (in artificial serum matrices) was also investigated. DPV was applied to detect a lower concentration of DIC+, resulting in a detection limit of 0.9 ± 0.06 µM. While the presence of BSA affected CV, demonstrated as reduced current responses, DPV was confirmed to be an efficient method for lowering concentrations of the dibucaine detection in the artificial serum matrix in the presence of BSA, with a limit of detection (LOD) of 1.9 ± 0.12 µM. Multidisciplinary Digital Publishing Institute 2021 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/97051/1/ABSTRACT.pdf Almbrok Abdulla, Eissa Mohamed and Yusof, Nor Azah and Abdullah, Jaafar and Mohd Zawawi, Ruzniza (2021) Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces. Chemosensors, 9 (1). pp. 1-15. ISSN 2227-9040 https://www.mdpi.com/2227-9040/9/1/15 10.3390/chemosensors9010015
spellingShingle Almbrok Abdulla, Eissa Mohamed
Yusof, Nor Azah
Abdullah, Jaafar
Mohd Zawawi, Ruzniza
Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
title Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
title_full Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
title_fullStr Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
title_full_unstemmed Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
title_short Electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
title_sort electrochemical detection of a local anesthetic dibucaine at arrays of micro liquid liquid interfaces
url http://psasir.upm.edu.my/id/eprint/97051/
http://psasir.upm.edu.my/id/eprint/97051/
http://psasir.upm.edu.my/id/eprint/97051/
http://psasir.upm.edu.my/id/eprint/97051/1/ABSTRACT.pdf