An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques

In diagnosing coronary artery disease, measurement of the cross-sectional area of the lumen, maximum and minimum diameter is very important. Mainly, it will be used to confirm the diagnosing, to predict the stenosis if any and to ensure the size of the stent to be used. However, the measurement only...

Full description

Bibliographic Details
Main Authors: Kutty, Suhaili Beeran, O. K. Rahmat, Rahmita Wirza, Kassim, Sazzli Shahlan, Madzin, Hizmawati, Hamdan, Hazlina
Format: Article
Published: Institute of Advanced Engineering and Science 2021
Online Access:http://psasir.upm.edu.my/id/eprint/95784/
_version_ 1848862220553814016
author Kutty, Suhaili Beeran
O. K. Rahmat, Rahmita Wirza
Kassim, Sazzli Shahlan
Madzin, Hizmawati
Hamdan, Hazlina
author_facet Kutty, Suhaili Beeran
O. K. Rahmat, Rahmita Wirza
Kassim, Sazzli Shahlan
Madzin, Hizmawati
Hamdan, Hazlina
author_sort Kutty, Suhaili Beeran
building UPM Institutional Repository
collection Online Access
description In diagnosing coronary artery disease, measurement of the cross-sectional area of the lumen, maximum and minimum diameter is very important. Mainly, it will be used to confirm the diagnosing, to predict the stenosis if any and to ensure the size of the stent to be used. However, the measurement only offers by the existing software and some of the software needs human interaction to complete the process. The purpose of this paper is to present the algorithm to measure the region of interest (ROI) on intravascular ultrasound (IVUS) using an image processing technique. The methodology starts with image acquisition process followed by image segmentation. After that, border detection for each ROI was detected and the algorithm was applied to calculate the corresponding region. The result shows that the measurement is accurate and could be used not only for IVUS but applicable to solid circle and unsymmetrical circle shape.
first_indexed 2025-11-15T13:13:34Z
format Article
id upm-95784
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T13:13:34Z
publishDate 2021
publisher Institute of Advanced Engineering and Science
recordtype eprints
repository_type Digital Repository
spelling upm-957842023-04-05T03:35:08Z http://psasir.upm.edu.my/id/eprint/95784/ An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques Kutty, Suhaili Beeran O. K. Rahmat, Rahmita Wirza Kassim, Sazzli Shahlan Madzin, Hizmawati Hamdan, Hazlina In diagnosing coronary artery disease, measurement of the cross-sectional area of the lumen, maximum and minimum diameter is very important. Mainly, it will be used to confirm the diagnosing, to predict the stenosis if any and to ensure the size of the stent to be used. However, the measurement only offers by the existing software and some of the software needs human interaction to complete the process. The purpose of this paper is to present the algorithm to measure the region of interest (ROI) on intravascular ultrasound (IVUS) using an image processing technique. The methodology starts with image acquisition process followed by image segmentation. After that, border detection for each ROI was detected and the algorithm was applied to calculate the corresponding region. The result shows that the measurement is accurate and could be used not only for IVUS but applicable to solid circle and unsymmetrical circle shape. Institute of Advanced Engineering and Science 2021 Article PeerReviewed Kutty, Suhaili Beeran and O. K. Rahmat, Rahmita Wirza and Kassim, Sazzli Shahlan and Madzin, Hizmawati and Hamdan, Hazlina (2021) An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques. Bulletin of Electrical Engineering and Informatics, 10 (1). 508 - 515. ISSN 2302-9285 https://beei.org/index.php/EEI/article/view/2694 10.11591/eei.v10i1.2694
spellingShingle Kutty, Suhaili Beeran
O. K. Rahmat, Rahmita Wirza
Kassim, Sazzli Shahlan
Madzin, Hizmawati
Hamdan, Hazlina
An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
title An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
title_full An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
title_fullStr An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
title_full_unstemmed An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
title_short An algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
title_sort algorithm to measure unsymmetrical circle shape of intravascular ultrasound image using image processing techniques
url http://psasir.upm.edu.my/id/eprint/95784/
http://psasir.upm.edu.my/id/eprint/95784/
http://psasir.upm.edu.my/id/eprint/95784/