Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia

With the ageing infrastructure and fast-growing demand faced by utilities worldwide, voltage uprating is one of the most effective solutions and strategic approaches in asset management decisions. In this study, a systematic voltage uprating method is used to propose the new voltage level, based on...

Full description

Bibliographic Details
Main Authors: Mohd Nor, Shamsul Fahmi, Ab Kadir, Mohd Zainal Abidin, Mohd Ariffin, Azrul, Osman, Miszaina, Abd Rahman, Muhammad Syahmi, Mohd Zainuddin, Noorlina
Format: Article
Published: MDPI AG 2021
Online Access:http://psasir.upm.edu.my/id/eprint/95277/
_version_ 1848862117201969152
author Mohd Nor, Shamsul Fahmi
Ab Kadir, Mohd Zainal Abidin
Mohd Ariffin, Azrul
Osman, Miszaina
Abd Rahman, Muhammad Syahmi
Mohd Zainuddin, Noorlina
author_facet Mohd Nor, Shamsul Fahmi
Ab Kadir, Mohd Zainal Abidin
Mohd Ariffin, Azrul
Osman, Miszaina
Abd Rahman, Muhammad Syahmi
Mohd Zainuddin, Noorlina
author_sort Mohd Nor, Shamsul Fahmi
building UPM Institutional Repository
collection Online Access
description With the ageing infrastructure and fast-growing demand faced by utilities worldwide, voltage uprating is one of the most effective solutions and strategic approaches in asset management decisions. In this study, a systematic voltage uprating method is used to propose the new voltage level, based on the existing transmission lines’ physical structure, by utilising appropriate techniques. Prior to work conducted, the existing 132 kV transmission line was first examined in terms of the clearances and the components attached, and a technical issue on the clearance under still air was found to be a significant concern, particularly on phase-to-earth arrangements. Next, the proposed techniques and processes, by increasing the insulation strength and improving air conductor clearances, were used for the individual existing 132 kV transmission tower. The proposed voltage uprating of the 132 kV transmission tower comprehensively examines phase-to-earth under normal and extreme wind conditions based on electrical clearance requirements for 275 kV transmission lines. The proposed uprating model was then simulated using the Finite Element Method (FEM)-based commercial software under several lightning conditions, i.e., various basic lightning insulation levels (BIL) and different flashover mechanisms, taking into consideration still air and wind conditions for the voltage profile and its insulation strength analyses. The study found that the voltage profile condition for the proposed voltage uprating model was able to withstand its BIL under all conditions and thus satisfied the electrical requirement needed.
first_indexed 2025-11-15T13:11:55Z
format Article
id upm-95277
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T13:11:55Z
publishDate 2021
publisher MDPI AG
recordtype eprints
repository_type Digital Repository
spelling upm-952772023-03-06T04:30:42Z http://psasir.upm.edu.my/id/eprint/95277/ Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia Mohd Nor, Shamsul Fahmi Ab Kadir, Mohd Zainal Abidin Mohd Ariffin, Azrul Osman, Miszaina Abd Rahman, Muhammad Syahmi Mohd Zainuddin, Noorlina With the ageing infrastructure and fast-growing demand faced by utilities worldwide, voltage uprating is one of the most effective solutions and strategic approaches in asset management decisions. In this study, a systematic voltage uprating method is used to propose the new voltage level, based on the existing transmission lines’ physical structure, by utilising appropriate techniques. Prior to work conducted, the existing 132 kV transmission line was first examined in terms of the clearances and the components attached, and a technical issue on the clearance under still air was found to be a significant concern, particularly on phase-to-earth arrangements. Next, the proposed techniques and processes, by increasing the insulation strength and improving air conductor clearances, were used for the individual existing 132 kV transmission tower. The proposed voltage uprating of the 132 kV transmission tower comprehensively examines phase-to-earth under normal and extreme wind conditions based on electrical clearance requirements for 275 kV transmission lines. The proposed uprating model was then simulated using the Finite Element Method (FEM)-based commercial software under several lightning conditions, i.e., various basic lightning insulation levels (BIL) and different flashover mechanisms, taking into consideration still air and wind conditions for the voltage profile and its insulation strength analyses. The study found that the voltage profile condition for the proposed voltage uprating model was able to withstand its BIL under all conditions and thus satisfied the electrical requirement needed. MDPI AG 2021-09-29 Article PeerReviewed Mohd Nor, Shamsul Fahmi and Ab Kadir, Mohd Zainal Abidin and Mohd Ariffin, Azrul and Osman, Miszaina and Abd Rahman, Muhammad Syahmi and Mohd Zainuddin, Noorlina (2021) Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia. Applied Sciences, 11 (19). art. no. 9087. pp. 1-19. ISSN 2076-3417 https://www.mdpi.com/2076-3417/11/19/9087 10.3390/app11199087
spellingShingle Mohd Nor, Shamsul Fahmi
Ab Kadir, Mohd Zainal Abidin
Mohd Ariffin, Azrul
Osman, Miszaina
Abd Rahman, Muhammad Syahmi
Mohd Zainuddin, Noorlina
Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia
title Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia
title_full Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia
title_fullStr Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia
title_full_unstemmed Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia
title_short Systematic approaches and analyses on voltage uprating of 132 kV transmission lines: a case study in Malaysia
title_sort systematic approaches and analyses on voltage uprating of 132 kv transmission lines: a case study in malaysia
url http://psasir.upm.edu.my/id/eprint/95277/
http://psasir.upm.edu.my/id/eprint/95277/
http://psasir.upm.edu.my/id/eprint/95277/