Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface

Artificial obstructions on the underside of receiver tubes can increase the heat transfer coefficient between the receiver tubes (Heat Exchanger, HX) of Parabolic Trough Collectors (PTCs) and water as a working fluid. In this study, we numerically and experimentally tested the behavior of laminar mi...

Full description

Bibliographic Details
Main Authors: Abdulhamed, Ali Jaber, Adam, Nor Mariah, Ab. Kadir, Mohd. Zainal Abidin, Hairuddin, Abdul Aziz
Format: Article
Language:English
Published: Medwell Journal 2020
Online Access:http://psasir.upm.edu.my/id/eprint/89043/
http://psasir.upm.edu.my/id/eprint/89043/1/TUBE.pdf
_version_ 1848860759360012288
author Abdulhamed, Ali Jaber
Adam, Nor Mariah
Ab. Kadir, Mohd. Zainal Abidin
Hairuddin, Abdul Aziz
author_facet Abdulhamed, Ali Jaber
Adam, Nor Mariah
Ab. Kadir, Mohd. Zainal Abidin
Hairuddin, Abdul Aziz
author_sort Abdulhamed, Ali Jaber
building UPM Institutional Repository
collection Online Access
description Artificial obstructions on the underside of receiver tubes can increase the heat transfer coefficient between the receiver tubes (Heat Exchanger, HX) of Parabolic Trough Collectors (PTCs) and water as a working fluid. In this study, we numerically and experimentally tested the behavior of laminar mixed convective heat transfer in HX tube installed with baffles. These baffles are rings that are connected together axially and connected radially to the inner tube surface. Using ANSYS fluent Version 15.0, we performed computation fluid dynamics modeling to achieve heat transfer enhancement in HX tubes equipped with turbulator baffles under laminar flow conditions. Moreover, the effects of Pitch ratio (P/D) = 3, 6 and 10 and Reynolds number Re#480 were recorded. The novel application of the rings that are connected axially together and radially to the inner tube surface contributes to the long-term storage of thermal energy and promotes heat transfer via. conduction from the tube surface to the center line of the water flow within a short period. In the study, the baffles generated a vortex to increase the Nusselt number (Nu) inside the HX. To simulate heat flux, we calculated the constant wall heat flux of the receiver tube using an electric heater. Results indicated that using 20 rings as baffles instead of plain tubes improves heat transfer by up to 75%. As P/D decreased and re increased, the heat transfer rate, friction factor (f) and Thermal Enhancement Factor (TEF) increased.
first_indexed 2025-11-15T12:50:20Z
format Article
id upm-89043
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:50:20Z
publishDate 2020
publisher Medwell Journal
recordtype eprints
repository_type Digital Repository
spelling upm-890432021-09-21T22:45:30Z http://psasir.upm.edu.my/id/eprint/89043/ Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface Abdulhamed, Ali Jaber Adam, Nor Mariah Ab. Kadir, Mohd. Zainal Abidin Hairuddin, Abdul Aziz Artificial obstructions on the underside of receiver tubes can increase the heat transfer coefficient between the receiver tubes (Heat Exchanger, HX) of Parabolic Trough Collectors (PTCs) and water as a working fluid. In this study, we numerically and experimentally tested the behavior of laminar mixed convective heat transfer in HX tube installed with baffles. These baffles are rings that are connected together axially and connected radially to the inner tube surface. Using ANSYS fluent Version 15.0, we performed computation fluid dynamics modeling to achieve heat transfer enhancement in HX tubes equipped with turbulator baffles under laminar flow conditions. Moreover, the effects of Pitch ratio (P/D) = 3, 6 and 10 and Reynolds number Re#480 were recorded. The novel application of the rings that are connected axially together and radially to the inner tube surface contributes to the long-term storage of thermal energy and promotes heat transfer via. conduction from the tube surface to the center line of the water flow within a short period. In the study, the baffles generated a vortex to increase the Nusselt number (Nu) inside the HX. To simulate heat flux, we calculated the constant wall heat flux of the receiver tube using an electric heater. Results indicated that using 20 rings as baffles instead of plain tubes improves heat transfer by up to 75%. As P/D decreased and re increased, the heat transfer rate, friction factor (f) and Thermal Enhancement Factor (TEF) increased. Medwell Journal 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/89043/1/TUBE.pdf Abdulhamed, Ali Jaber and Adam, Nor Mariah and Ab. Kadir, Mohd. Zainal Abidin and Hairuddin, Abdul Aziz (2020) Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface. Journal of Engineering and Applied Sciences, 15 (3). 762 - 772. ISSN 1816-949X; ESSN: 1818-7803 http://www.medwelljournals.com/abstract/?doi=jeasci.2020.762.772 10.36478/jeasci.2020.762.772
spellingShingle Abdulhamed, Ali Jaber
Adam, Nor Mariah
Ab. Kadir, Mohd. Zainal Abidin
Hairuddin, Abdul Aziz
Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
title Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
title_full Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
title_fullStr Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
title_full_unstemmed Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
title_short Flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
title_sort flow and thermal mechanisms in receiver tube of parabolic trough collectors with rings axially connected together and radially connected to the inner tube surface
url http://psasir.upm.edu.my/id/eprint/89043/
http://psasir.upm.edu.my/id/eprint/89043/
http://psasir.upm.edu.my/id/eprint/89043/
http://psasir.upm.edu.my/id/eprint/89043/1/TUBE.pdf