Extraction of winding parameters for 33/11 kV, 30 MVA transformer based on finite element method for frequency response modelling
This paper proposes an alternative approach to extract transformer’s winding parameters of resistance (R), inductance (L), capacitance (C) and conductance (G) based on Finite Element Method (FEM). The capacitance and conductance were computed based on Fast Multiple Method (FMM) and Method of Moment...
| Main Authors: | Murthy, Avinash Srikanta, Azis, Norhafiz, Jasni, Jasronita, Othman, Mohammad Lutfi, Mohd Yousof, Mohd Fairouz, Talib, Mohd Aizam |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Public Library of Science
2020
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/88942/ http://psasir.upm.edu.my/id/eprint/88942/1/FEM.pdf |
Similar Items
Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Investigation on the transient voltage in a 11 kV transformer under lightning surges
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Investigation of the impact of a standard lightning impulse on the structure of an 11/0.415 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2022)
by: Murthy, Avinash Srikanta, et al.
Published: (2022)
Investigation on the resonant oscillations in an 11 kV distribution transformer under standard and chopped lightning impulse overvoltages with different shield placement configurations
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
Structural deformation and displacement of a disc winding due to standard switching impulse voltage via finite element method
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2024)
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2024)
Electromagnetic force distribution computations due to switching surge in disc-type winding
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2023)
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2023)
Frequency responses of transformer winding deformations based on finite element modeling under transient overvoltage impulses
by: Murthy, Avinash Srikanta
Published: (2020)
by: Murthy, Avinash Srikanta
Published: (2020)
Off-line partial discharge measurement and localization for a 33/6.9 kV in-service transformer
by: Selva, A. M., et al.
Published: (2022)
by: Selva, A. M., et al.
Published: (2022)
Design and Simulation of Differential Protective Relay (DPR) to 33/11kv Delta-Wye Transformer Using Saber Software Simulator
by: Othman, Muhammad Murtadha
Published: (2000)
by: Othman, Muhammad Murtadha
Published: (2000)
Evaluation of 11kv XLPE Cable
by: Bashir Umar, Nouruddeen
Published: (2006)
by: Bashir Umar, Nouruddeen
Published: (2006)
Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
by: Mohd Nawi, Zawati
Published: (2012)
by: Mohd Nawi, Zawati
Published: (2012)
3.3 kV SiC JBS diode configurable rectifier module
by: Mouawad, Bassem, et al.
Published: (2017)
by: Mouawad, Bassem, et al.
Published: (2017)
Frequency response of transformer winding to investigate the influence of RLC
by: Al-Ameri, S., et al.
Published: (2019)
by: Al-Ameri, S., et al.
Published: (2019)
PLC design for automatic power transfer of 11kv switchgear
by: Wahid, Herman, et al.
Published: (2022)
by: Wahid, Herman, et al.
Published: (2022)
CREATION OF SHAREHOLDERS WEALTH: INDIAN EVIDENCE WITH EVA AND MVA
by: Shah, Vividh
Published: (2010)
by: Shah, Vividh
Published: (2010)
Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
The influence of cavity size and location within insulation paper on the Partial Discharge activities
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
Continuous monitoring on 132kV line in reducing flashovers due to lightning
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
Classification of fault and stray gassing in transformer by using duval pentagon and machine learning algorithms
by: Haw, Jia Yong, et al.
Published: (2022)
by: Haw, Jia Yong, et al.
Published: (2022)
Lightning study and experience on the first 500kV transmission line arrester in Malaysia
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
Evaluation and assessment of transformer failure on 132kV substation
by: Mohammed Ariff, Mohd Hatta, et al.
Published: (2008)
by: Mohammed Ariff, Mohd Hatta, et al.
Published: (2008)
Stator and rotor vent modelling in a MVA rated synchronous machine
by: Connor, Peter H., et al.
Published: (2016)
by: Connor, Peter H., et al.
Published: (2016)
Investigating Relationship between EVA and MVA of Selected Construction Companies in Malaysia
by: Panigrahi, Shrikant, et al.
Published: (2014)
by: Panigrahi, Shrikant, et al.
Published: (2014)
Development of a real time expert system for 11KV distribution automation
by: Uddin,, Md. Safi, et al.
Published: (2006)
by: Uddin,, Md. Safi, et al.
Published: (2006)
Development of a real time expert system for 11KV distribution automation
by: Uddin, , Md. Safi, et al.
Published: (2006)
by: Uddin, , Md. Safi, et al.
Published: (2006)
Analysis of protection system setting in 11KV distribution system / Ammar Alamshah
by: Ammar, Alamshah
Published: (2020)
by: Ammar, Alamshah
Published: (2020)
High impedance fault detection and localization in 11kV distribution system / Mohd Syukri Ali
by: Mohd Syukri , Ali
Published: (2018)
by: Mohd Syukri , Ali
Published: (2018)
Experience and long term performance of 132kV overhead lines gapless-type surge arrester
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
Assessment of transformer health index using different model
by: Jasni, Jasronita, et al.
Published: (2017)
by: Jasni, Jasronita, et al.
Published: (2017)
Development of TNB distribution network risk based asset replacement policy and guideline for medium voltage primary equipment
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
A comprehensive power restoration approach using rule-based method for 11kV distribution network
by: Khalid, Abd Rahman, et al.
Published: (2008)
by: Khalid, Abd Rahman, et al.
Published: (2008)
Dynamic performance analysis of a 3.3 kV SiC MOSFET half-bridge module with parallel chips and body-diode freewheeling
by: Hussein, Abdallah, et al.
Published: (2018)
by: Hussein, Abdallah, et al.
Published: (2018)
Power Quality Improvement Using Distribution Static Compensator (D-Statcom) On 11 Kv Distribution System
by: Hj.Abdul Wahab, Noor Izzri
Published: (2002)
by: Hj.Abdul Wahab, Noor Izzri
Published: (2002)
Lightning impulse strength of 275 kV and 132 kV tower with composite crossarm
by: Abd Rahman, Muhammad Syahmi, et al.
Published: (2019)
by: Abd Rahman, Muhammad Syahmi, et al.
Published: (2019)
Health index as a tool for transformers asset management
by: Azmi, Akmalina, et al.
Published: (2015)
by: Azmi, Akmalina, et al.
Published: (2015)
Partial discharge in medium and high voltage electrical devices
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
Loss-of-life analyses based on modified arrhenius and relative aging rate for non-thermally upgraded paper in oil-immersed transformer
by: Saleh, Najiyah, et al.
Published: (2024)
by: Saleh, Najiyah, et al.
Published: (2024)
Similar Items
-
Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings
by: Murthy, Avinash Srikanta, et al.
Published: (2020) -
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018) -
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018) -
Investigation on the transient voltage in a 11 kV transformer under lightning surges
by: Murthy, Avinash Srikanta, et al.
Published: (2018) -
Investigation of the impact of a standard lightning impulse on the structure of an 11/0.415 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2022)