Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter

Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less...

Full description

Bibliographic Details
Main Authors: Yusup Lada, Musa, Mohd Radzi, Mohd Amran, Jasni, Jasronita, Hizam, Hashim, Jidin, Auzani, Mohamad, Syahrul Hisham
Format: Article
Published: Institute of Advanced Engineering and Science 2020
Online Access:http://psasir.upm.edu.my/id/eprint/87117/
_version_ 1848860365002113024
author Yusup Lada, Musa
Mohd Radzi, Mohd Amran
Jasni, Jasronita
Hizam, Hashim
Jidin, Auzani
Mohamad, Syahrul Hisham
author_facet Yusup Lada, Musa
Mohd Radzi, Mohd Amran
Jasni, Jasronita
Hizam, Hashim
Jidin, Auzani
Mohamad, Syahrul Hisham
author_sort Yusup Lada, Musa
building UPM Institutional Repository
collection Online Access
description Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less power devices requirement and simple design. MLI CHB is also capable to produce possible output voltage at twice of the number of DC source which in this case of APF is the best suited topology to replace with the conventional six -step inverter. This paper presents the performance of three- phase three-wire CHB MLI used in Shunt Active Power Filter (SAPF) based on Direct Current Control (DCC) and Indirect Current Control (ICC) schemes. Both schemes are developed and verified in MATLAB/Simulink. The simulation results show that both current control algorithms are capable to mitigate load current with Total Harmonic Distortion below than the permissible value based on IEEE 519 standard.
first_indexed 2025-11-15T12:44:04Z
format Article
id upm-87117
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T12:44:04Z
publishDate 2020
publisher Institute of Advanced Engineering and Science
recordtype eprints
repository_type Digital Repository
spelling upm-871172024-01-24T02:49:40Z http://psasir.upm.edu.my/id/eprint/87117/ Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter Yusup Lada, Musa Mohd Radzi, Mohd Amran Jasni, Jasronita Hizam, Hashim Jidin, Auzani Mohamad, Syahrul Hisham Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less power devices requirement and simple design. MLI CHB is also capable to produce possible output voltage at twice of the number of DC source which in this case of APF is the best suited topology to replace with the conventional six -step inverter. This paper presents the performance of three- phase three-wire CHB MLI used in Shunt Active Power Filter (SAPF) based on Direct Current Control (DCC) and Indirect Current Control (ICC) schemes. Both schemes are developed and verified in MATLAB/Simulink. The simulation results show that both current control algorithms are capable to mitigate load current with Total Harmonic Distortion below than the permissible value based on IEEE 519 standard. Institute of Advanced Engineering and Science 2020 Article PeerReviewed Yusup Lada, Musa and Mohd Radzi, Mohd Amran and Jasni, Jasronita and Hizam, Hashim and Jidin, Auzani and Mohamad, Syahrul Hisham (2020) Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter. International Journal of Power Electronics and Drive Systems, 11 (3). 1430 - 1440. ISSN 2088-8694; ESSN: 2722-256X https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20677 10.11591/ijpeds.v11.i3.pp1430-1440
spellingShingle Yusup Lada, Musa
Mohd Radzi, Mohd Amran
Jasni, Jasronita
Hizam, Hashim
Jidin, Auzani
Mohamad, Syahrul Hisham
Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
title Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
title_full Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
title_fullStr Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
title_full_unstemmed Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
title_short Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
title_sort performance of three-phase three-wire cascaded h-bridge multilevel inverter-based shunt active power filter
url http://psasir.upm.edu.my/id/eprint/87117/
http://psasir.upm.edu.my/id/eprint/87117/
http://psasir.upm.edu.my/id/eprint/87117/