Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter
Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less...
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Published: |
Institute of Advanced Engineering and Science
2020
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/87117/ |
| _version_ | 1848860365002113024 |
|---|---|
| author | Yusup Lada, Musa Mohd Radzi, Mohd Amran Jasni, Jasronita Hizam, Hashim Jidin, Auzani Mohamad, Syahrul Hisham |
| author_facet | Yusup Lada, Musa Mohd Radzi, Mohd Amran Jasni, Jasronita Hizam, Hashim Jidin, Auzani Mohamad, Syahrul Hisham |
| author_sort | Yusup Lada, Musa |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less power devices requirement and simple design. MLI CHB is also capable to produce possible output voltage at twice of the number of DC source which in this case of APF is the best suited topology to replace with the conventional six -step inverter. This paper presents the performance of three- phase three-wire CHB MLI used in Shunt Active Power Filter (SAPF) based on Direct Current Control (DCC) and Indirect Current Control (ICC) schemes. Both schemes are developed and verified in MATLAB/Simulink. The simulation results show that both current control algorithms are capable to mitigate load current with Total Harmonic Distortion below than the permissible value based on IEEE 519 standard. |
| first_indexed | 2025-11-15T12:44:04Z |
| format | Article |
| id | upm-87117 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| last_indexed | 2025-11-15T12:44:04Z |
| publishDate | 2020 |
| publisher | Institute of Advanced Engineering and Science |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-871172024-01-24T02:49:40Z http://psasir.upm.edu.my/id/eprint/87117/ Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter Yusup Lada, Musa Mohd Radzi, Mohd Amran Jasni, Jasronita Hizam, Hashim Jidin, Auzani Mohamad, Syahrul Hisham Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less power devices requirement and simple design. MLI CHB is also capable to produce possible output voltage at twice of the number of DC source which in this case of APF is the best suited topology to replace with the conventional six -step inverter. This paper presents the performance of three- phase three-wire CHB MLI used in Shunt Active Power Filter (SAPF) based on Direct Current Control (DCC) and Indirect Current Control (ICC) schemes. Both schemes are developed and verified in MATLAB/Simulink. The simulation results show that both current control algorithms are capable to mitigate load current with Total Harmonic Distortion below than the permissible value based on IEEE 519 standard. Institute of Advanced Engineering and Science 2020 Article PeerReviewed Yusup Lada, Musa and Mohd Radzi, Mohd Amran and Jasni, Jasronita and Hizam, Hashim and Jidin, Auzani and Mohamad, Syahrul Hisham (2020) Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter. International Journal of Power Electronics and Drive Systems, 11 (3). 1430 - 1440. ISSN 2088-8694; ESSN: 2722-256X https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20677 10.11591/ijpeds.v11.i3.pp1430-1440 |
| spellingShingle | Yusup Lada, Musa Mohd Radzi, Mohd Amran Jasni, Jasronita Hizam, Hashim Jidin, Auzani Mohamad, Syahrul Hisham Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter |
| title | Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter |
| title_full | Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter |
| title_fullStr | Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter |
| title_full_unstemmed | Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter |
| title_short | Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter |
| title_sort | performance of three-phase three-wire cascaded h-bridge multilevel inverter-based shunt active power filter |
| url | http://psasir.upm.edu.my/id/eprint/87117/ http://psasir.upm.edu.my/id/eprint/87117/ http://psasir.upm.edu.my/id/eprint/87117/ |