Thermoluminescence Dosimetric Characteristics of Fabricated Germanium (Ge) Doped Optical Fibres for Electron Beams Dosimetry: A Preliminary Study
The basic dosimetric favourable responses of tailored fabricated germanium (Ge) doped cylindrical optical fibres, make use of 2.3% mol have been extensively studied with clinical electron beams irradiation in terms of dose linearity, reproducibility, fading signals, minimum detectable dose (MDD), en...
| Main Authors: | Zakaria, Zabariah, Mohd Noor, Noramaliza, Abdul Aziz, Mohd Zahri |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
2020
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/86349/ http://psasir.upm.edu.my/id/eprint/86349/1/ABSTRACT%20%281%29.pdf |
Similar Items
Thermoluminescence dosimetric characteristics of fabricated germanium (Ge) doped optical fibres for electron beams dosimetry: a preliminary study
by: Zabariah Zakaria,, et al.
Published: (2020)
by: Zabariah Zakaria,, et al.
Published: (2020)
Development of fabricated germanium-doped optical fibres for breast cancer electron beam dosimetry
by: Zakaria, Zabariah
Published: (2023)
by: Zakaria, Zabariah
Published: (2023)
Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
by: Lam, Siok Ee, et al.
Published: (2019)
by: Lam, Siok Ee, et al.
Published: (2019)
Radiotherapy dosimetry and the thermoluminescence characteristics of Ge-doped fibres of differing germanium dopant concentration and outer diameter
by: Mohd Noor, Noramaliza, et al.
Published: (2016)
by: Mohd Noor, Noramaliza, et al.
Published: (2016)
Investigation of thermoluminescence dosimetry characteristics of ge-doped optical fibres and photonic cystal fibre for postal dosimetry audit of radiotherapy photon and electron beams
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
Different germanium dopant concentration and the thermoluminescence characteristics of flat Ge-doped optical fibres
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2017)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2017)
Investigation of thermoluminescene dosimetric characteristics of Ge-doped optical fibres and photonic crystal fibre for postal dosimetry audit of radiotherapy photon and electron beams.
by: Mohd. Noor, Noramaliza, et al.
by: Mohd. Noor, Noramaliza, et al.
Dosimetric characteristics of fabricated ge-doped silica optical fibres for small field radiation dosimetry in radiotherapy
by: Lam, Siok Ee
Published: (2019)
by: Lam, Siok Ee
Published: (2019)
Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
by: Abdullah, N., et al.
Published: (2022)
by: Abdullah, N., et al.
Published: (2022)
Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
by: Mohd Rais, Nur Nadiah, et al.
Published: (2019)
by: Mohd Rais, Nur Nadiah, et al.
Published: (2019)
Fabricated germanium-doped optical fibres for computed tomography dosimetry: Glow curve characteristics
by: Rais, N. N. M., et al.
Published: (2021)
by: Rais, N. N. M., et al.
Published: (2021)
Characterization of Ge-doped optical fibres for MV radiotherapy dosimetry
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
Flat Ge-doped optical fibres for food irradiation dosimetry
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
The thermoluminescence response of Ge-doped flat fibre for proton beam measurements: a preliminary study
by: Hassan, M. F., et al.
Published: (2017)
by: Hassan, M. F., et al.
Published: (2017)
Fabricated germanium-doped optical fibres for computed tomography dosimetry: Glow curve characteristics
by: Rais, N.N.M., et al.
Published: (2021)
by: Rais, N.N.M., et al.
Published: (2021)
Time-temperature profiles effect on thermoluminescence glow curve formation of germanium doped optical fibres
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2022)
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2022)
Tailored Ge-doped fibres for passive electron radiotherapy dosimetry
by: Siti Nurasiah, M. N, et al.
Published: (2020)
by: Siti Nurasiah, M. N, et al.
Published: (2020)
Collapsed photonic crystal fibre thermoluminescence dosimetry for external beam radiotherapy
by: Begum, M., et al.
Published: (2023)
by: Begum, M., et al.
Published: (2023)
Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
by: Hassan, M.F., et al.
Published: (2023)
by: Hassan, M.F., et al.
Published: (2023)
Thermoluminescence kinetic parameters of proton-irradiated germanium doped flat-shape optical fibres
by: Hassan, M.F., et al.
Published: (2022)
by: Hassan, M.F., et al.
Published: (2022)
Thermoluminescence trap parameters of tailor-made Ge-doped optical fibre dosimeter
by: Al-mugren, K.S., et al.
Published: (2024)
by: Al-mugren, K.S., et al.
Published: (2024)
The thermoluminescence response of Ge-doped optical fibres to X-ray photon irradiation
by: Hashim, Suhairul, et al.
Published: (2008)
by: Hashim, Suhairul, et al.
Published: (2008)
Ge-doped silica fibre proton beam measurements: thermoluminescence dose-response and glow curve characteristics
by: Hassan, M. F., et al.
Published: (2019)
by: Hassan, M. F., et al.
Published: (2019)
Effective Atomic Number of Ge-doped and Al-doped Optical Fibres for Radiation Dosimetry Purposes.
by: Saripan, M. Iqbal, et al.
Published: (2013)
by: Saripan, M. Iqbal, et al.
Published: (2013)
Dosimetric characterisation of the nanodot optically stimulated luminescent dosimeter for use in national electron beam dosimetry audit services for radiotherapy facilities
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
Thermoluminescence energy response of germanium doped optical fibre using Monte Carlo N-particle code simulation
by: Asni, Hazila, et al.
Published: (2009)
by: Asni, Hazila, et al.
Published: (2009)
Thermoluminescence response of Ge-doped optical fiber dosimeters with different core sizes
by: Begumi, Mahfuza, et al.
Published: (2013)
by: Begumi, Mahfuza, et al.
Published: (2013)
Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
by: Sarhan, H.G., et al.
Published: (2023)
by: Sarhan, H.G., et al.
Published: (2023)
Real-time germanium-doped optical fibers for clinical computed tomography dosimetry
by: Sarhan, H.G., et al.
Published: (2023)
by: Sarhan, H.G., et al.
Published: (2023)
Fabricated germanium-doped silica optical fibres: a novel dose meter for clinical blood irradiation
by: Ku Shaidaton Akmar Ku Bakar,, et al.
Published: (2025)
by: Ku Shaidaton Akmar Ku Bakar,, et al.
Published: (2025)
Fabricated germanium-doped silica optical fibres: a novel dose indicator for clinical blood irradiation
by: Mohd Noor, Noramaliza, et al.
Published: (2025)
by: Mohd Noor, Noramaliza, et al.
Published: (2025)
Irradiated glass and thermoluminescence yield: Dosimetric utility reviewed
by: Bradley, D. A. *, et al.
Published: (2020)
by: Bradley, D. A. *, et al.
Published: (2020)
Dopant concentration and thermoluminescence (TL) properties of tailor-made Ge-doped SiO2 fibres
by: Zahaimi, Nurul Arina, et al.
Published: (2014)
by: Zahaimi, Nurul Arina, et al.
Published: (2014)
Nanosynthesis, and structural and dosimetric characteristics of undoped and copper manganese-doped calcium borate thermoluminescent dosimeters
by: Haghiri, Maryam Erfani
Published: (2013)
by: Haghiri, Maryam Erfani
Published: (2013)
Dosimetric characterisation of silica fibre thermoluminescent sensors for medical and non medical applications / Farhad Moradi
by: Farhad , Moradi
Published: (2018)
by: Farhad , Moradi
Published: (2018)
Response of fabricated germanium optical fibre subjected to low dose neutron-gamma irradiation
by: Mustafa, Salasiah, et al.
Published: (2018)
by: Mustafa, Salasiah, et al.
Published: (2018)
Fabricated germanium-doped silica optical fibres: a novel dose meter for clinical blood irradiation )gentian optik silika terdop germanium: suatu meter dos baharu untuk penyinaran darah klinikal)
by: Ku Bakar, Ku Shaidaton Akmar, et al.
Published: (2025)
by: Ku Bakar, Ku Shaidaton Akmar, et al.
Published: (2025)
Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014)
Latest developments in silica-based thermoluminescence spectrometry and dosimetry
by: Bradley, D.A., et al.
Published: (2016)
by: Bradley, D.A., et al.
Published: (2016)
Thermoluminescence features of commercial glass and retrospective accident dosimetry
by: Yasmin, S., et al.
Published: (2020)
by: Yasmin, S., et al.
Published: (2020)
Similar Items
-
Thermoluminescence dosimetric characteristics of fabricated germanium (Ge) doped optical fibres for electron beams dosimetry: a preliminary study
by: Zabariah Zakaria,, et al.
Published: (2020) -
Development of fabricated germanium-doped optical fibres for breast cancer electron beam dosimetry
by: Zakaria, Zabariah
Published: (2023) -
Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
by: Lam, Siok Ee, et al.
Published: (2019) -
Radiotherapy dosimetry and the thermoluminescence characteristics of Ge-doped fibres of differing germanium dopant concentration and outer diameter
by: Mohd Noor, Noramaliza, et al.
Published: (2016) -
Investigation of thermoluminescence dosimetry characteristics of ge-doped optical fibres and photonic cystal fibre for postal dosimetry audit of radiotherapy photon and electron beams
by: Mohd Noor, Noramaliza, et al.
Published: (2014)