Optimization of extraction methods and detectors for heavy metal analysis in sediment

The optimization analysis, extractions of metals (Zinc, Cadmium, Lead, and Copper) content in Certified Reference Material, BCR ®-667 of estuarine sediment was carried out by different procedures of acid digestion such hydrochloric acid-nitric acid-hydrofluoric acid, nitric acid-perchloric acid, and...

Full description

Bibliographic Details
Main Authors: Lasumin, Nazerita, Mohamed @ Mohd Ramli, Khairul Nizam, Muhammad, Norfarahana, Yusoff, Abdul Hafidz
Format: Article
Language:English
Published: Science and Engineering Research Support Society 2019
Online Access:http://psasir.upm.edu.my/id/eprint/81567/
http://psasir.upm.edu.my/id/eprint/81567/1/Optimization%20of%20extraction%20methods%20and%20detectors%20for%20heavy%20metal%20analysis%20in%20sediment.pdf
_version_ 1848859136879493120
author Lasumin, Nazerita
Mohamed @ Mohd Ramli, Khairul Nizam
Muhammad, Norfarahana
Yusoff, Abdul Hafidz
author_facet Lasumin, Nazerita
Mohamed @ Mohd Ramli, Khairul Nizam
Muhammad, Norfarahana
Yusoff, Abdul Hafidz
author_sort Lasumin, Nazerita
building UPM Institutional Repository
collection Online Access
description The optimization analysis, extractions of metals (Zinc, Cadmium, Lead, and Copper) content in Certified Reference Material, BCR ®-667 of estuarine sediment was carried out by different procedures of acid digestion such hydrochloric acid-nitric acid-hydrofluoric acid, nitric acid-perchloric acid, and sulphuric acid-hydrogen peroxide mixtures. These metals concentrations were determined by using Differential Pulse Stripping Voltammetry (DPSV) and Inductive Coupled Plasma-Mass Spectrometry (ICP-MS). The purpose was to determine these metals (Zn, Cd, Pb, Cu) concentration in sediment samples simultaneously in good precision and accuracy measurement. The results showed both have small standard deviation indicates good precision of metals determinations in both detectors. The accuracy for DPSV ranged from 18.85-154.38% and ICP-MS ranged from 75.28-90.13%. Zn, Cd, Pb, and Cu were simultaneously measured in BCR ®-667. When the optimized method was applied into real sediment samples, both determinations showed a good precision in analysis but ICP-MS was selected as the detector. It measured all the metals of interest (Zn, Cd, Pb, Cu) in the real sediment sample simultaneously.
first_indexed 2025-11-15T12:24:33Z
format Article
id upm-81567
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:24:33Z
publishDate 2019
publisher Science and Engineering Research Support Society
recordtype eprints
repository_type Digital Repository
spelling upm-815672020-10-30T21:19:18Z http://psasir.upm.edu.my/id/eprint/81567/ Optimization of extraction methods and detectors for heavy metal analysis in sediment Lasumin, Nazerita Mohamed @ Mohd Ramli, Khairul Nizam Muhammad, Norfarahana Yusoff, Abdul Hafidz The optimization analysis, extractions of metals (Zinc, Cadmium, Lead, and Copper) content in Certified Reference Material, BCR ®-667 of estuarine sediment was carried out by different procedures of acid digestion such hydrochloric acid-nitric acid-hydrofluoric acid, nitric acid-perchloric acid, and sulphuric acid-hydrogen peroxide mixtures. These metals concentrations were determined by using Differential Pulse Stripping Voltammetry (DPSV) and Inductive Coupled Plasma-Mass Spectrometry (ICP-MS). The purpose was to determine these metals (Zn, Cd, Pb, Cu) concentration in sediment samples simultaneously in good precision and accuracy measurement. The results showed both have small standard deviation indicates good precision of metals determinations in both detectors. The accuracy for DPSV ranged from 18.85-154.38% and ICP-MS ranged from 75.28-90.13%. Zn, Cd, Pb, and Cu were simultaneously measured in BCR ®-667. When the optimized method was applied into real sediment samples, both determinations showed a good precision in analysis but ICP-MS was selected as the detector. It measured all the metals of interest (Zn, Cd, Pb, Cu) in the real sediment sample simultaneously. Science and Engineering Research Support Society 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/81567/1/Optimization%20of%20extraction%20methods%20and%20detectors%20for%20heavy%20metal%20analysis%20in%20sediment.pdf Lasumin, Nazerita and Mohamed @ Mohd Ramli, Khairul Nizam and Muhammad, Norfarahana and Yusoff, Abdul Hafidz (2019) Optimization of extraction methods and detectors for heavy metal analysis in sediment. International Journal of Advanced Science and Technology, 28 (18). pp. 44-57. ISSN 2005-4238; ESSN: 2207-6360
spellingShingle Lasumin, Nazerita
Mohamed @ Mohd Ramli, Khairul Nizam
Muhammad, Norfarahana
Yusoff, Abdul Hafidz
Optimization of extraction methods and detectors for heavy metal analysis in sediment
title Optimization of extraction methods and detectors for heavy metal analysis in sediment
title_full Optimization of extraction methods and detectors for heavy metal analysis in sediment
title_fullStr Optimization of extraction methods and detectors for heavy metal analysis in sediment
title_full_unstemmed Optimization of extraction methods and detectors for heavy metal analysis in sediment
title_short Optimization of extraction methods and detectors for heavy metal analysis in sediment
title_sort optimization of extraction methods and detectors for heavy metal analysis in sediment
url http://psasir.upm.edu.my/id/eprint/81567/
http://psasir.upm.edu.my/id/eprint/81567/1/Optimization%20of%20extraction%20methods%20and%20detectors%20for%20heavy%20metal%20analysis%20in%20sediment.pdf