Design and calibration of pinch force measurement using strain gauge for post-stroke patients

Two fingers strength is an indicative measurement of pinch impairment. Conventionally, Fugl Meyer Upper Extremity Assessment (FMA-UE) is the primary standard to measure pinch strength of post-stroke survivors. In literature, the evaluation method performed by the th...

Full description

Bibliographic Details
Main Authors: Alsayed, Abdallah, Raja Ahmad, Raja Mohd Kamil, Ramli, Hafiz Rashidi, As'arry, Azizan
Format: Article
Language:English
Published: Penerbit UTHM 2019
Online Access:http://psasir.upm.edu.my/id/eprint/81098/
http://psasir.upm.edu.my/id/eprint/81098/1/PINCH%20FORCE.pdf
_version_ 1848859022598340608
author Alsayed, Abdallah
Raja Ahmad, Raja Mohd Kamil
Ramli, Hafiz Rashidi
As'arry, Azizan
author_facet Alsayed, Abdallah
Raja Ahmad, Raja Mohd Kamil
Ramli, Hafiz Rashidi
As'arry, Azizan
author_sort Alsayed, Abdallah
building UPM Institutional Repository
collection Online Access
description Two fingers strength is an indicative measurement of pinch impairment. Conventionally, Fugl Meyer Upper Extremity Assessment (FMA-UE) is the primary standard to measure pinch strength of post-stroke survivors. In literature, the evaluation method performed by the therapist is subjective and exposed to inter-rater and intra-rater reliabilities. Recently, force-sensing resistors were implemented to measure two fingers force, but these sensors are subjected to nonlinearity, high hysteresis, and voltage drift. This paper presents a design of pinch force measurement based on the strain gauge. The pinch sensor was calibrated within a range of between 0 N to 50 N over a pinching length of 20 mm with a linearity error of 0.0123% and hysteresis of 0.513% during the loading and unloading process. The voltage drift has an average of 0.24% over 20 minutes. The pinch force measurement system reveals an objective pinch force measurements in evaluating the rehabilitation progress of post-stroke patients.
first_indexed 2025-11-15T12:22:44Z
format Article
id upm-81098
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:22:44Z
publishDate 2019
publisher Penerbit UTHM
recordtype eprints
repository_type Digital Repository
spelling upm-810982020-09-09T08:15:57Z http://psasir.upm.edu.my/id/eprint/81098/ Design and calibration of pinch force measurement using strain gauge for post-stroke patients Alsayed, Abdallah Raja Ahmad, Raja Mohd Kamil Ramli, Hafiz Rashidi As'arry, Azizan Two fingers strength is an indicative measurement of pinch impairment. Conventionally, Fugl Meyer Upper Extremity Assessment (FMA-UE) is the primary standard to measure pinch strength of post-stroke survivors. In literature, the evaluation method performed by the therapist is subjective and exposed to inter-rater and intra-rater reliabilities. Recently, force-sensing resistors were implemented to measure two fingers force, but these sensors are subjected to nonlinearity, high hysteresis, and voltage drift. This paper presents a design of pinch force measurement based on the strain gauge. The pinch sensor was calibrated within a range of between 0 N to 50 N over a pinching length of 20 mm with a linearity error of 0.0123% and hysteresis of 0.513% during the loading and unloading process. The voltage drift has an average of 0.24% over 20 minutes. The pinch force measurement system reveals an objective pinch force measurements in evaluating the rehabilitation progress of post-stroke patients. Penerbit UTHM 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/81098/1/PINCH%20FORCE.pdf Alsayed, Abdallah and Raja Ahmad, Raja Mohd Kamil and Ramli, Hafiz Rashidi and As'arry, Azizan (2019) Design and calibration of pinch force measurement using strain gauge for post-stroke patients. International Journal of Integrated Engineering, 11 (4). pp. 40-50. ISSN 2229-838X; ESSN: 2600-7916 https://publisher.uthm.edu.my/ojs/index.php/ijie 10.30880/ijie.2019.11.04.005
spellingShingle Alsayed, Abdallah
Raja Ahmad, Raja Mohd Kamil
Ramli, Hafiz Rashidi
As'arry, Azizan
Design and calibration of pinch force measurement using strain gauge for post-stroke patients
title Design and calibration of pinch force measurement using strain gauge for post-stroke patients
title_full Design and calibration of pinch force measurement using strain gauge for post-stroke patients
title_fullStr Design and calibration of pinch force measurement using strain gauge for post-stroke patients
title_full_unstemmed Design and calibration of pinch force measurement using strain gauge for post-stroke patients
title_short Design and calibration of pinch force measurement using strain gauge for post-stroke patients
title_sort design and calibration of pinch force measurement using strain gauge for post-stroke patients
url http://psasir.upm.edu.my/id/eprint/81098/
http://psasir.upm.edu.my/id/eprint/81098/
http://psasir.upm.edu.my/id/eprint/81098/
http://psasir.upm.edu.my/id/eprint/81098/1/PINCH%20FORCE.pdf