Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester

The detection of 3- and 2-MCPD ester and glycidyl ester was transformed from selected ion monitoring (SIM) mode to multiple reaction monitoring (MRM) mode by gas chromatography triple quadrupole spectrometry. The derivatization process was adapted from AOCS method Cd 29a-13. The results showed that...

Full description

Bibliographic Details
Main Authors: Goh, Kok Ming, Wong, Yu Hua, Ang, May Yen, Yeo, Samuel Chao Ming, Abas, Faridah, Lai, Oi Ming, Tan, Chin Ping
Format: Article
Language:English
Published: Elsevier 2019
Online Access:http://psasir.upm.edu.my/id/eprint/80976/
http://psasir.upm.edu.my/id/eprint/80976/1/SIM.pdf
_version_ 1848858994071830528
author Goh, Kok Ming
Wong, Yu Hua
Ang, May Yen
Yeo, Samuel Chao Ming
Abas, Faridah
Lai, Oi Ming
Tan, Chin Ping
author_facet Goh, Kok Ming
Wong, Yu Hua
Ang, May Yen
Yeo, Samuel Chao Ming
Abas, Faridah
Lai, Oi Ming
Tan, Chin Ping
author_sort Goh, Kok Ming
building UPM Institutional Repository
collection Online Access
description The detection of 3- and 2-MCPD ester and glycidyl ester was transformed from selected ion monitoring (SIM) mode to multiple reaction monitoring (MRM) mode by gas chromatography triple quadrupole spectrometry. The derivatization process was adapted from AOCS method Cd 29a-13. The results showed that the coefficient of determination (R2) of all detected compounds obtained from both detection mode was comparable, which falls between 0.997 and 0.999. The limit of detection and quantification (LOD and LOQ) were improved in MRM mode as compared to SIM mode. In MRM mode, the LOD of 3- and 2-MCPD ester was achieved 0.01 mg/kg while the LOQ was 0.05 mg/kg. Besides, LOD and LOQ of glycidyl ester were 0.024 and 0.06 mg/kg respectively. A blank spiked with MCPD esters (0.03, 0.10 and 0.50 mg/kg) and GE (0.06, 0.24 and 1.20 mg/kg) were chosen for repeatability and recovery tests. MRM mode showed better repeatability in area ratio and recovery with relative standard deviation (RSD %) < 5% for 2-, 3-MCPD ester at 0.5 mg/kg and GE at 1.2 mg/kg. Quantification of 22 food samples from different category were performed by repeated injections in both detection modes. Briefly, the contaminants from crude palm oil, mustard and olive oil were present in minute amount which below the LOD or LOQ in both detection modes. Sample from chocolate and infant formula products showed certain level of MCPD esters and GE, and their detection was more precisely quantitated based on MRM mode. Besides, margarine products showed a higher level of contaminations due to the high fat content in these products. MRM mode detection was proven to provide precise data with low RSD % in different food matrices. MRM mode detection was robust and selective for MCPD esters and GE analyses, it should be applied to determine the concentration of MCPD esters and GE contaminations in food.
first_indexed 2025-11-15T12:22:17Z
format Article
id upm-80976
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:22:17Z
publishDate 2019
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling upm-809762020-10-14T20:36:52Z http://psasir.upm.edu.my/id/eprint/80976/ Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester Goh, Kok Ming Wong, Yu Hua Ang, May Yen Yeo, Samuel Chao Ming Abas, Faridah Lai, Oi Ming Tan, Chin Ping The detection of 3- and 2-MCPD ester and glycidyl ester was transformed from selected ion monitoring (SIM) mode to multiple reaction monitoring (MRM) mode by gas chromatography triple quadrupole spectrometry. The derivatization process was adapted from AOCS method Cd 29a-13. The results showed that the coefficient of determination (R2) of all detected compounds obtained from both detection mode was comparable, which falls between 0.997 and 0.999. The limit of detection and quantification (LOD and LOQ) were improved in MRM mode as compared to SIM mode. In MRM mode, the LOD of 3- and 2-MCPD ester was achieved 0.01 mg/kg while the LOQ was 0.05 mg/kg. Besides, LOD and LOQ of glycidyl ester were 0.024 and 0.06 mg/kg respectively. A blank spiked with MCPD esters (0.03, 0.10 and 0.50 mg/kg) and GE (0.06, 0.24 and 1.20 mg/kg) were chosen for repeatability and recovery tests. MRM mode showed better repeatability in area ratio and recovery with relative standard deviation (RSD %) < 5% for 2-, 3-MCPD ester at 0.5 mg/kg and GE at 1.2 mg/kg. Quantification of 22 food samples from different category were performed by repeated injections in both detection modes. Briefly, the contaminants from crude palm oil, mustard and olive oil were present in minute amount which below the LOD or LOQ in both detection modes. Sample from chocolate and infant formula products showed certain level of MCPD esters and GE, and their detection was more precisely quantitated based on MRM mode. Besides, margarine products showed a higher level of contaminations due to the high fat content in these products. MRM mode detection was proven to provide precise data with low RSD % in different food matrices. MRM mode detection was robust and selective for MCPD esters and GE analyses, it should be applied to determine the concentration of MCPD esters and GE contaminations in food. Elsevier 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/80976/1/SIM.pdf Goh, Kok Ming and Wong, Yu Hua and Ang, May Yen and Yeo, Samuel Chao Ming and Abas, Faridah and Lai, Oi Ming and Tan, Chin Ping (2019) Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester. Food Research International, 121. pp. 553-560. ISSN 0963-9969 https://www.sciencedirect.com/science/article/pii/S0963996918309608#! 10.1016/j.foodres.2018.12.013
spellingShingle Goh, Kok Ming
Wong, Yu Hua
Ang, May Yen
Yeo, Samuel Chao Ming
Abas, Faridah
Lai, Oi Ming
Tan, Chin Ping
Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
title Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
title_full Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
title_fullStr Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
title_full_unstemmed Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
title_short Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
title_sort comparison assessment between sim and mrm mode in the analysis of 3-mcpd ester, 2-mcpd ester and glycidyl ester
url http://psasir.upm.edu.my/id/eprint/80976/
http://psasir.upm.edu.my/id/eprint/80976/
http://psasir.upm.edu.my/id/eprint/80976/
http://psasir.upm.edu.my/id/eprint/80976/1/SIM.pdf