Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding

The aim of this study is to evaluate effective dose received by participants from Lung Cancer Screening program in Institut Kanser Negara (IKN), Putrajaya. This retrospective study was performed between April 2016 – December 2016 where all scanning acquisition protocols and dose information from for...

Full description

Bibliographic Details
Main Authors: Abdul Karim, Muhammad Khalis, Abdul Rahim, Noraini, Mustafa, Siti Norsyafiqah, Sabarudin, Akmal, Ibahim, Mohd Johari
Format: Article
Language:English
Published: Institute of Physics Publishing 2019
Online Access:http://psasir.upm.edu.my/id/eprint/80745/
http://psasir.upm.edu.my/id/eprint/80745/1/LUNG.pdf
_version_ 1848858949856526336
author Abdul Karim, Muhammad Khalis
Abdul Rahim, Noraini
Mustafa, Siti Norsyafiqah
Sabarudin, Akmal
Ibahim, Mohd Johari
author_facet Abdul Karim, Muhammad Khalis
Abdul Rahim, Noraini
Mustafa, Siti Norsyafiqah
Sabarudin, Akmal
Ibahim, Mohd Johari
author_sort Abdul Karim, Muhammad Khalis
building UPM Institutional Repository
collection Online Access
description The aim of this study is to evaluate effective dose received by participants from Lung Cancer Screening program in Institut Kanser Negara (IKN), Putrajaya. This retrospective study was performed between April 2016 – December 2016 where all scanning acquisition protocols and dose information from forty (40) participants were recorded and investigated. The screening process involves two types of imaging technique, the Dual Energy Subtraction (DES) Chest Xray and Low-Dose Computed Tomography (LDCT) imaging technique. Participant’s effective dose (ED) from DES and MSCT were analysed by using PCXMC (Version 2.0, Finland) and CT-EXPO (Version 2.3, Germany) software, respectively. It was observed that the mean (±SD) value for DES (at 60 kV), DES (at 120 kV) and MSCT examinations were 0.006 ± 0.005 mSv, 0.018 ± 0.005 mSv and 1.558 ± 0.129 mSv, respectively. In a whole, the total cumulative ED values for participants were ranged from 1.376 mSv to 1.986 mSv. It was summarized that both optimized techniques were useful for screening needs and the ED value from this study were lower when compared to other established reference.
first_indexed 2025-11-15T12:21:35Z
format Article
id upm-80745
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:21:35Z
publishDate 2019
publisher Institute of Physics Publishing
recordtype eprints
repository_type Digital Repository
spelling upm-807452020-11-12T00:37:09Z http://psasir.upm.edu.my/id/eprint/80745/ Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding Abdul Karim, Muhammad Khalis Abdul Rahim, Noraini Mustafa, Siti Norsyafiqah Sabarudin, Akmal Ibahim, Mohd Johari The aim of this study is to evaluate effective dose received by participants from Lung Cancer Screening program in Institut Kanser Negara (IKN), Putrajaya. This retrospective study was performed between April 2016 – December 2016 where all scanning acquisition protocols and dose information from forty (40) participants were recorded and investigated. The screening process involves two types of imaging technique, the Dual Energy Subtraction (DES) Chest Xray and Low-Dose Computed Tomography (LDCT) imaging technique. Participant’s effective dose (ED) from DES and MSCT were analysed by using PCXMC (Version 2.0, Finland) and CT-EXPO (Version 2.3, Germany) software, respectively. It was observed that the mean (±SD) value for DES (at 60 kV), DES (at 120 kV) and MSCT examinations were 0.006 ± 0.005 mSv, 0.018 ± 0.005 mSv and 1.558 ± 0.129 mSv, respectively. In a whole, the total cumulative ED values for participants were ranged from 1.376 mSv to 1.986 mSv. It was summarized that both optimized techniques were useful for screening needs and the ED value from this study were lower when compared to other established reference. Institute of Physics Publishing 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/80745/1/LUNG.pdf Abdul Karim, Muhammad Khalis and Abdul Rahim, Noraini and Mustafa, Siti Norsyafiqah and Sabarudin, Akmal and Ibahim, Mohd Johari (2019) Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding. Journal of Physics: Conference Series, 1248. pp. 1-5. ISSN 1742-6588; ESSN: 1742-6596 https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012012/pdf 10.1088/1742-6596/1248/1/012012
spellingShingle Abdul Karim, Muhammad Khalis
Abdul Rahim, Noraini
Mustafa, Siti Norsyafiqah
Sabarudin, Akmal
Ibahim, Mohd Johari
Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding
title Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding
title_full Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding
title_fullStr Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding
title_full_unstemmed Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding
title_short Assessment of radiation effective dose from lung cancer screening pilot project in Institut Kanser Negara: a preliminary finding
title_sort assessment of radiation effective dose from lung cancer screening pilot project in institut kanser negara: a preliminary finding
url http://psasir.upm.edu.my/id/eprint/80745/
http://psasir.upm.edu.my/id/eprint/80745/
http://psasir.upm.edu.my/id/eprint/80745/
http://psasir.upm.edu.my/id/eprint/80745/1/LUNG.pdf