Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements
This paper presents an investigation on the resonant oscillations of an 11 kV layer-type winding transformer under standard and chopped lightning impulse overvoltage conditions based on calculated parameters. The resistances, inductances and capacitances were calculated in order to develop the trans...
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI
2019
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/80327/ http://psasir.upm.edu.my/id/eprint/80327/1/Investigation%20on%20the%20resonant%20oscillations%20in%20an%2011kV%20distribution%20transformer%20under%20standard%20and%20chopped%20lightning%20impulse%20overvoltages%20with%20different%20configurations%20of%20shield%20placements.pdf |
| _version_ | 1848858889903144960 |
|---|---|
| author | Murthy, Avinash Srikanta Azis, Norhafiz Mohd Yousof, Mohd Fairouz Jasni, Jasronita Othman, Mohammad Lutfi Das, Bhaba Priyo Talib, Mohd Aizam |
| author_facet | Murthy, Avinash Srikanta Azis, Norhafiz Mohd Yousof, Mohd Fairouz Jasni, Jasronita Othman, Mohammad Lutfi Das, Bhaba Priyo Talib, Mohd Aizam |
| author_sort | Murthy, Avinash Srikanta |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | This paper presents an investigation on the resonant oscillations of an 11 kV layer-type winding transformer under standard and chopped lightning impulse overvoltage conditions based on calculated parameters. The resistances, inductances and capacitances were calculated in order to develop the transformer winding equivalent circuit. The impulse overvoltages were applied to the high voltage (HV) winding and the resonant oscillations were simulated for each of the layers based on different electrostatic shield placement configurations. It is found that the placement of grounded shields between layer 13 and layer 14 results in the highest resonant oscillation and non-linear initial voltage distribution. The oscillation and linear stress distributions are at the lowest for shield placement between the HV and low voltage (LV) windings. |
| first_indexed | 2025-11-15T12:20:37Z |
| format | Article |
| id | upm-80327 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T12:20:37Z |
| publishDate | 2019 |
| publisher | MDPI |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-803272020-10-21T19:17:38Z http://psasir.upm.edu.my/id/eprint/80327/ Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements Murthy, Avinash Srikanta Azis, Norhafiz Mohd Yousof, Mohd Fairouz Jasni, Jasronita Othman, Mohammad Lutfi Das, Bhaba Priyo Talib, Mohd Aizam This paper presents an investigation on the resonant oscillations of an 11 kV layer-type winding transformer under standard and chopped lightning impulse overvoltage conditions based on calculated parameters. The resistances, inductances and capacitances were calculated in order to develop the transformer winding equivalent circuit. The impulse overvoltages were applied to the high voltage (HV) winding and the resonant oscillations were simulated for each of the layers based on different electrostatic shield placement configurations. It is found that the placement of grounded shields between layer 13 and layer 14 results in the highest resonant oscillation and non-linear initial voltage distribution. The oscillation and linear stress distributions are at the lowest for shield placement between the HV and low voltage (LV) windings. MDPI 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/80327/1/Investigation%20on%20the%20resonant%20oscillations%20in%20an%2011kV%20distribution%20transformer%20under%20standard%20and%20chopped%20lightning%20impulse%20overvoltages%20with%20different%20configurations%20of%20shield%20placements.pdf Murthy, Avinash Srikanta and Azis, Norhafiz and Mohd Yousof, Mohd Fairouz and Jasni, Jasronita and Othman, Mohammad Lutfi and Das, Bhaba Priyo and Talib, Mohd Aizam (2019) Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements. Energies, 12 (8). pp. 1-24. ISSN 1996-1073 https://www.researchgate.net/publication/332483363_Investigation_on_the_Resonant_Oscillations_in_an_11_kV_Distribution_Transformer_under_Standard_and_Chopped_Lightning_Impulse_Overvoltages_with_Different_Shield_Placement_Configurations 10.3390/en12081466 |
| spellingShingle | Murthy, Avinash Srikanta Azis, Norhafiz Mohd Yousof, Mohd Fairouz Jasni, Jasronita Othman, Mohammad Lutfi Das, Bhaba Priyo Talib, Mohd Aizam Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| title | Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| title_full | Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| title_fullStr | Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| title_full_unstemmed | Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| title_short | Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| title_sort | investigation on the resonant oscillations in an 11kv distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements |
| url | http://psasir.upm.edu.my/id/eprint/80327/ http://psasir.upm.edu.my/id/eprint/80327/ http://psasir.upm.edu.my/id/eprint/80327/ http://psasir.upm.edu.my/id/eprint/80327/1/Investigation%20on%20the%20resonant%20oscillations%20in%20an%2011kV%20distribution%20transformer%20under%20standard%20and%20chopped%20lightning%20impulse%20overvoltages%20with%20different%20configurations%20of%20shield%20placements.pdf |