Energy audit of subcritical plant performance with different types of subbituminous coal

The energy used and energy waste are calculating accordingly and presented to the financial terms. Having said that, the energy audit is the activities of measuring the energy is being consumed and it also tells how efficiently and effectively the energy is being used. In addition, the energy audi...

Full description

Bibliographic Details
Main Authors: A. A., Nuraini, S., Salmi, A. A., Hairuddin
Format: Article
Published: Zibeline International Publishing 2019
Online Access:http://psasir.upm.edu.my/id/eprint/79668/
_version_ 1848858732023250944
author A. A., Nuraini
S., Salmi
A. A., Hairuddin
author_facet A. A., Nuraini
S., Salmi
A. A., Hairuddin
author_sort A. A., Nuraini
building UPM Institutional Repository
collection Online Access
description The energy used and energy waste are calculating accordingly and presented to the financial terms. Having said that, the energy audit is the activities of measuring the energy is being consumed and it also tells how efficiently and effectively the energy is being used. In addition, the energy audit critically identifies various weak at the field and becomes as a tools to inform the system to make and corrective actions, mitigation plant and the meantime monitor the performance. For this study, many parameters and calculation involved in an energy audit such as superheated steam temperature, superheated steam pressure, boiler drum level and other for the subcritical plant. For the condenser vacuum and condenser pressure, result shows within acceptance range which is between 65 to 95 bar. Besides that, the generator performance which indicate through generator active power and generator frequency, Hertz for all type of coal shows similar result which is within acceptable range. As a results, coal types D behave similar performance compare with designed coal type A. Overall, the energy audit gives very good assessment and valuable information on the plant performance and consequently depicts the plant life cycle.
first_indexed 2025-11-15T12:18:07Z
format Article
id upm-79668
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T12:18:07Z
publishDate 2019
publisher Zibeline International Publishing
recordtype eprints
repository_type Digital Repository
spelling upm-796682023-02-13T01:39:42Z http://psasir.upm.edu.my/id/eprint/79668/ Energy audit of subcritical plant performance with different types of subbituminous coal A. A., Nuraini S., Salmi A. A., Hairuddin The energy used and energy waste are calculating accordingly and presented to the financial terms. Having said that, the energy audit is the activities of measuring the energy is being consumed and it also tells how efficiently and effectively the energy is being used. In addition, the energy audit critically identifies various weak at the field and becomes as a tools to inform the system to make and corrective actions, mitigation plant and the meantime monitor the performance. For this study, many parameters and calculation involved in an energy audit such as superheated steam temperature, superheated steam pressure, boiler drum level and other for the subcritical plant. For the condenser vacuum and condenser pressure, result shows within acceptance range which is between 65 to 95 bar. Besides that, the generator performance which indicate through generator active power and generator frequency, Hertz for all type of coal shows similar result which is within acceptable range. As a results, coal types D behave similar performance compare with designed coal type A. Overall, the energy audit gives very good assessment and valuable information on the plant performance and consequently depicts the plant life cycle. Zibeline International Publishing 2019 Article PeerReviewed A. A., Nuraini and S., Salmi and A. A., Hairuddin (2019) Energy audit of subcritical plant performance with different types of subbituminous coal. Journal of Mechanical Engineering Research and Developments, 42 (4). pp. 264-268. ISSN 1024-1752 https://www.researchgate.net/publication/335982858_Energy_Audit_of_Sub_Critical_Plant_Performance_with_Different_Types_of_Sub_Bituminous_Coal 10.26480/jmerd.04.2019.264.268
spellingShingle A. A., Nuraini
S., Salmi
A. A., Hairuddin
Energy audit of subcritical plant performance with different types of subbituminous coal
title Energy audit of subcritical plant performance with different types of subbituminous coal
title_full Energy audit of subcritical plant performance with different types of subbituminous coal
title_fullStr Energy audit of subcritical plant performance with different types of subbituminous coal
title_full_unstemmed Energy audit of subcritical plant performance with different types of subbituminous coal
title_short Energy audit of subcritical plant performance with different types of subbituminous coal
title_sort energy audit of subcritical plant performance with different types of subbituminous coal
url http://psasir.upm.edu.my/id/eprint/79668/
http://psasir.upm.edu.my/id/eprint/79668/
http://psasir.upm.edu.my/id/eprint/79668/