False positive blood culture from automated microbial detection system in severe malaria – a case report

Automated microbial detection system (AMDs) are design to detect early growth of bacterial and fungal. We herein report a rare case of false positive blood culture by AMDs in Plasmodium falciparum infection. A 41-year-old previously healthy lady, with recent history of travelling to Lagos, Nigeria h...

Full description

Bibliographic Details
Main Authors: Mohd Rahim, Syarifah, Masri, Siti Norbaya, Ibrahim, Rosni
Format: Article
Language:English
Published: Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 2020
Online Access:http://psasir.upm.edu.my/id/eprint/76946/
http://psasir.upm.edu.my/id/eprint/76946/1/2020011612314952_MJMHS_0039.pdf
_version_ 1848858111836684288
author Mohd Rahim, Syarifah
Masri, Siti Norbaya
Ibrahim, Rosni
author_facet Mohd Rahim, Syarifah
Masri, Siti Norbaya
Ibrahim, Rosni
author_sort Mohd Rahim, Syarifah
building UPM Institutional Repository
collection Online Access
description Automated microbial detection system (AMDs) are design to detect early growth of bacterial and fungal. We herein report a rare case of false positive blood culture by AMDs in Plasmodium falciparum infection. A 41-year-old previously healthy lady, with recent history of travelling to Lagos, Nigeria had presented to the casualty with history of fever and lethargy for three days. There was no malaria prophylaxis taken prior to the travelling history. Peripheral blood smear confirmed the presence of young trophozoite of Plasmodium falciparum with parasitemia of 7%. Concurrent blood culture sent was positive, however all subcultures were negative for any growth. She was treated with intravenous artesunate however succumbed to death on the day of admission due to severe falciparum infection complicated with multiorgan failure and shock. The aim of this report is to highlight, the circumstances that can trigger the false positive AMDs detection and the possible underlying mechanism.
first_indexed 2025-11-15T12:08:15Z
format Article
id upm-76946
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:08:15Z
publishDate 2020
publisher Faculty of Medicine and Health Sciences, Universiti Putra Malaysia
recordtype eprints
repository_type Digital Repository
spelling upm-769462020-03-03T09:39:02Z http://psasir.upm.edu.my/id/eprint/76946/ False positive blood culture from automated microbial detection system in severe malaria – a case report Mohd Rahim, Syarifah Masri, Siti Norbaya Ibrahim, Rosni Automated microbial detection system (AMDs) are design to detect early growth of bacterial and fungal. We herein report a rare case of false positive blood culture by AMDs in Plasmodium falciparum infection. A 41-year-old previously healthy lady, with recent history of travelling to Lagos, Nigeria had presented to the casualty with history of fever and lethargy for three days. There was no malaria prophylaxis taken prior to the travelling history. Peripheral blood smear confirmed the presence of young trophozoite of Plasmodium falciparum with parasitemia of 7%. Concurrent blood culture sent was positive, however all subcultures were negative for any growth. She was treated with intravenous artesunate however succumbed to death on the day of admission due to severe falciparum infection complicated with multiorgan failure and shock. The aim of this report is to highlight, the circumstances that can trigger the false positive AMDs detection and the possible underlying mechanism. Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/76946/1/2020011612314952_MJMHS_0039.pdf Mohd Rahim, Syarifah and Masri, Siti Norbaya and Ibrahim, Rosni (2020) False positive blood culture from automated microbial detection system in severe malaria – a case report. Malaysian Journal of Medicine and Health Sciences, 16 (1). pp. 342-344. ISSN 1675-8544; ESSN: 2636-9346 https://medic.upm.edu.my/upload/dokumen/2020011612314952_MJMHS_0039.pdf
spellingShingle Mohd Rahim, Syarifah
Masri, Siti Norbaya
Ibrahim, Rosni
False positive blood culture from automated microbial detection system in severe malaria – a case report
title False positive blood culture from automated microbial detection system in severe malaria – a case report
title_full False positive blood culture from automated microbial detection system in severe malaria – a case report
title_fullStr False positive blood culture from automated microbial detection system in severe malaria – a case report
title_full_unstemmed False positive blood culture from automated microbial detection system in severe malaria – a case report
title_short False positive blood culture from automated microbial detection system in severe malaria – a case report
title_sort false positive blood culture from automated microbial detection system in severe malaria – a case report
url http://psasir.upm.edu.my/id/eprint/76946/
http://psasir.upm.edu.my/id/eprint/76946/
http://psasir.upm.edu.my/id/eprint/76946/1/2020011612314952_MJMHS_0039.pdf