The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation

We describe our technique of single-bundle PCL reconstruction using a bony femoral press-fit system. 9 patients underwent PCL reconstruction using our pressfit system. The surgical procedure is described in detail. Post-operatively, 5 patients were available for assessment and review. Four patients...

Full description

Bibliographic Details
Main Authors: Mohd Nasir, Mohd Nizlan, Hussin, Paisal, Yeak, Raymond Dieu Kiat, Saleh, Mohd Zaidi, Ahmad, Shahrulazua
Format: Article
Language:English
Published: Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 2019
Online Access:http://psasir.upm.edu.my/id/eprint/75583/
http://psasir.upm.edu.my/id/eprint/75583/1/2019100109151621_MJMHS_0111.pdf
_version_ 1848857729433600000
author Mohd Nasir, Mohd Nizlan
Hussin, Paisal
Yeak, Raymond Dieu Kiat
Saleh, Mohd Zaidi
Ahmad, Shahrulazua
author_facet Mohd Nasir, Mohd Nizlan
Hussin, Paisal
Yeak, Raymond Dieu Kiat
Saleh, Mohd Zaidi
Ahmad, Shahrulazua
author_sort Mohd Nasir, Mohd Nizlan
building UPM Institutional Repository
collection Online Access
description We describe our technique of single-bundle PCL reconstruction using a bony femoral press-fit system. 9 patients underwent PCL reconstruction using our pressfit system. The surgical procedure is described in detail. Post-operatively, 5 patients were available for assessment and review. Four patients gave a final Lysholm score of 92 – 100%. Three patients gave a Hospital for Special Surgery (HSS) score of excellent, one fair and one poor. Two patients gave a reduced Tegner activity score post-operatively while the other three gave a similar score post-operatively. Assessment using KT-1000 revealed four patients with a side-to-side difference of less than 3 mm (average side-to-side difference, 1.87 mm), while one patient exhibited a side-to-side difference of 5.8 mm. We believe that our technique enhances tunnel healing through usage of a bone-plug fixation and provides a cheap alternative for graft fixation on the femoral side in PCL reconstruction.
first_indexed 2025-11-15T12:02:11Z
format Article
id upm-75583
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T12:02:11Z
publishDate 2019
publisher Faculty of Medicine and Health Sciences, Universiti Putra Malaysia
recordtype eprints
repository_type Digital Repository
spelling upm-755832019-11-12T02:14:22Z http://psasir.upm.edu.my/id/eprint/75583/ The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation Mohd Nasir, Mohd Nizlan Hussin, Paisal Yeak, Raymond Dieu Kiat Saleh, Mohd Zaidi Ahmad, Shahrulazua We describe our technique of single-bundle PCL reconstruction using a bony femoral press-fit system. 9 patients underwent PCL reconstruction using our pressfit system. The surgical procedure is described in detail. Post-operatively, 5 patients were available for assessment and review. Four patients gave a final Lysholm score of 92 – 100%. Three patients gave a Hospital for Special Surgery (HSS) score of excellent, one fair and one poor. Two patients gave a reduced Tegner activity score post-operatively while the other three gave a similar score post-operatively. Assessment using KT-1000 revealed four patients with a side-to-side difference of less than 3 mm (average side-to-side difference, 1.87 mm), while one patient exhibited a side-to-side difference of 5.8 mm. We believe that our technique enhances tunnel healing through usage of a bone-plug fixation and provides a cheap alternative for graft fixation on the femoral side in PCL reconstruction. Faculty of Medicine and Health Sciences, Universiti Putra Malaysia 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/75583/1/2019100109151621_MJMHS_0111.pdf Mohd Nasir, Mohd Nizlan and Hussin, Paisal and Yeak, Raymond Dieu Kiat and Saleh, Mohd Zaidi and Ahmad, Shahrulazua (2019) The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation. Malaysian Journal of Medicine and Health Sciences, 15 (3). pp. 148-152. ISSN 1675-8544; ESSN: 2636-9346 https://medic.upm.edu.my/upload/dokumen/2019100109151621_MJMHS_0111.pdf
spellingShingle Mohd Nasir, Mohd Nizlan
Hussin, Paisal
Yeak, Raymond Dieu Kiat
Saleh, Mohd Zaidi
Ahmad, Shahrulazua
The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
title The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
title_full The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
title_fullStr The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
title_full_unstemmed The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
title_short The PUTRA press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
title_sort putra press-fit system as an alternative femoral fixation technique for posterior cruciate ligament reconstruction – a technical note and outcome evaluation
url http://psasir.upm.edu.my/id/eprint/75583/
http://psasir.upm.edu.my/id/eprint/75583/
http://psasir.upm.edu.my/id/eprint/75583/1/2019100109151621_MJMHS_0111.pdf