PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions

This paper presents a non-iterative technique that generates reference current to manage operation of a three-phase four-wire shunt active power filter which employs a three-leg split capacitor voltage source inverter (VSI) topology. The proposed technique integrates together a self-tuning-filter (S...

Full description

Bibliographic Details
Main Authors: Hoon, Yap, Mohd Radzi, Mohd Amran
Format: Article
Language:English
Published: Multidisciplinary Digital Publishing Institute (MDPI) 2018
Online Access:http://psasir.upm.edu.my/id/eprint/73543/
http://psasir.upm.edu.my/id/eprint/73543/1/PLL-less%20three-phase%20four-wire%20SAPF%20with%20STF-%D4%81%D4%9B0%20technique%20for%20harmonics%20mitigation%20under%20distorted%20supply%20voltage%20and%20unbalanced%20load%20conditions.pdf
_version_ 1848857298072502272
author Hoon, Yap
Mohd Radzi, Mohd Amran
author_facet Hoon, Yap
Mohd Radzi, Mohd Amran
author_sort Hoon, Yap
building UPM Institutional Repository
collection Online Access
description This paper presents a non-iterative technique that generates reference current to manage operation of a three-phase four-wire shunt active power filter which employs a three-leg split capacitor voltage source inverter (VSI) topology. The proposed technique integrates together a self-tuning-filter (STF) and direct-quadrature-zero (dq0) principle (referred here as STF-dq0), allowing the controlled shunt active power filter (SAPF) to perform effectively under distorted source voltages and unbalanced load conditions. Unlike the previous technique developed based on the standard dq0 principle, the proposed technique does not require any service from a phase-locked loop (PLL) where two STFs are applied to separate harmonic and fundamental elements for the purpose of generating synchronization phases and reference current, respectively. Simulation work which includes connection of the SAPF circuits, design of control techniques and all the necessary assessments are conducted in MATLAB-Simulink platform. Performance achieved by the SAPF while utilizing the proposed technique is thoroughly investigated and benchmarked with that demonstrated by the SAPF while using the standard dq0 technique, to evaluate the inherent advantages. Exhaustive simulation results are provided and thoroughly discussed to support design concept, effectiveness, and benefits of the proposed technique.
first_indexed 2025-11-15T11:55:19Z
format Article
id upm-73543
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:55:19Z
publishDate 2018
publisher Multidisciplinary Digital Publishing Institute (MDPI)
recordtype eprints
repository_type Digital Repository
spelling upm-735432020-06-09T00:31:01Z http://psasir.upm.edu.my/id/eprint/73543/ PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions Hoon, Yap Mohd Radzi, Mohd Amran This paper presents a non-iterative technique that generates reference current to manage operation of a three-phase four-wire shunt active power filter which employs a three-leg split capacitor voltage source inverter (VSI) topology. The proposed technique integrates together a self-tuning-filter (STF) and direct-quadrature-zero (dq0) principle (referred here as STF-dq0), allowing the controlled shunt active power filter (SAPF) to perform effectively under distorted source voltages and unbalanced load conditions. Unlike the previous technique developed based on the standard dq0 principle, the proposed technique does not require any service from a phase-locked loop (PLL) where two STFs are applied to separate harmonic and fundamental elements for the purpose of generating synchronization phases and reference current, respectively. Simulation work which includes connection of the SAPF circuits, design of control techniques and all the necessary assessments are conducted in MATLAB-Simulink platform. Performance achieved by the SAPF while utilizing the proposed technique is thoroughly investigated and benchmarked with that demonstrated by the SAPF while using the standard dq0 technique, to evaluate the inherent advantages. Exhaustive simulation results are provided and thoroughly discussed to support design concept, effectiveness, and benefits of the proposed technique. Multidisciplinary Digital Publishing Institute (MDPI) 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/73543/1/PLL-less%20three-phase%20four-wire%20SAPF%20with%20STF-%D4%81%D4%9B0%20technique%20for%20harmonics%20mitigation%20under%20distorted%20supply%20voltage%20and%20unbalanced%20load%20conditions.pdf Hoon, Yap and Mohd Radzi, Mohd Amran (2018) PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions. Energies, 11 (8). art. no. 2143. pp. 1-27. ISSN 1996-1073; ESSN: 1996-1073 https://www.mdpi.com/1996-1073/11/8/2143/htm 10.3390/en11082143
spellingShingle Hoon, Yap
Mohd Radzi, Mohd Amran
PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
title PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
title_full PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
title_fullStr PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
title_full_unstemmed PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
title_short PLL-less three-phase four-wire SAPF with STF-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
title_sort pll-less three-phase four-wire sapf with stf-ԁԛ0 technique for harmonics mitigation under distorted supply voltage and unbalanced load conditions
url http://psasir.upm.edu.my/id/eprint/73543/
http://psasir.upm.edu.my/id/eprint/73543/
http://psasir.upm.edu.my/id/eprint/73543/
http://psasir.upm.edu.my/id/eprint/73543/1/PLL-less%20three-phase%20four-wire%20SAPF%20with%20STF-%D4%81%D4%9B0%20technique%20for%20harmonics%20mitigation%20under%20distorted%20supply%20voltage%20and%20unbalanced%20load%20conditions.pdf