Detecting hydrogen using TiO2-B2O3 at different operating temperature

Performance of TiO2-B2O3 gas sensor that annealed using nitrogen at 650°C for 30 minutes was observed and analyzed. The sensing film of the gas sensor was prepared by mixing TiO2-B2O3 with an organic binder. The sensing film was characterized by field emission scanning electron microscopy (FESEM) an...

Full description

Bibliographic Details
Main Authors: Mohd Chachuli, Siti Amaniah, Hamidon, Mohd Nizar, Mamat @ Mat Nazir, Md Shuhazlly, Ertugrul, Mehmet
Format: Conference or Workshop Item
Language:English
Published: IEEE 2018
Online Access:http://psasir.upm.edu.my/id/eprint/69241/
http://psasir.upm.edu.my/id/eprint/69241/1/Detecting%20hydrogen%20using%20TiO2-B2O3%20at%20different%20operating%20temperature.pdf
_version_ 1848856349684793344
author Mohd Chachuli, Siti Amaniah
Hamidon, Mohd Nizar
Mamat @ Mat Nazir, Md Shuhazlly
Ertugrul, Mehmet
author_facet Mohd Chachuli, Siti Amaniah
Hamidon, Mohd Nizar
Mamat @ Mat Nazir, Md Shuhazlly
Ertugrul, Mehmet
author_sort Mohd Chachuli, Siti Amaniah
building UPM Institutional Repository
collection Online Access
description Performance of TiO2-B2O3 gas sensor that annealed using nitrogen at 650°C for 30 minutes was observed and analyzed. The sensing film of the gas sensor was prepared by mixing TiO2-B2O3 with an organic binder. The sensing film was characterized by field emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD). The gas sensor was exposed to hydrogen at a concentration of 100-1000 ppm with operating temperatures of 100°C and 200°C. However, no response was detected for 100 ppm at 100°C. But, as the operating temperature was increased to 200°C, the gas sensor indicated a good response for 100 ppm of hydrogen. The gas sensor exhibited p-type response based on decreased current when exposed to hydrogen. The sensitivity of gas sensor was calculated at 1.00, 2.18 and 3.58 for 100 ppm, 500 ppm and 1000 ppm respectively, at an operating temperature of 200°C.
first_indexed 2025-11-15T11:40:15Z
format Conference or Workshop Item
id upm-69241
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:40:15Z
publishDate 2018
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling upm-692412020-05-06T03:38:03Z http://psasir.upm.edu.my/id/eprint/69241/ Detecting hydrogen using TiO2-B2O3 at different operating temperature Mohd Chachuli, Siti Amaniah Hamidon, Mohd Nizar Mamat @ Mat Nazir, Md Shuhazlly Ertugrul, Mehmet Performance of TiO2-B2O3 gas sensor that annealed using nitrogen at 650°C for 30 minutes was observed and analyzed. The sensing film of the gas sensor was prepared by mixing TiO2-B2O3 with an organic binder. The sensing film was characterized by field emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD). The gas sensor was exposed to hydrogen at a concentration of 100-1000 ppm with operating temperatures of 100°C and 200°C. However, no response was detected for 100 ppm at 100°C. But, as the operating temperature was increased to 200°C, the gas sensor indicated a good response for 100 ppm of hydrogen. The gas sensor exhibited p-type response based on decreased current when exposed to hydrogen. The sensitivity of gas sensor was calculated at 1.00, 2.18 and 3.58 for 100 ppm, 500 ppm and 1000 ppm respectively, at an operating temperature of 200°C. IEEE 2018 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/69241/1/Detecting%20hydrogen%20using%20TiO2-B2O3%20at%20different%20operating%20temperature.pdf Mohd Chachuli, Siti Amaniah and Hamidon, Mohd Nizar and Mamat @ Mat Nazir, Md Shuhazlly and Ertugrul, Mehmet (2018) Detecting hydrogen using TiO2-B2O3 at different operating temperature. In: 13th IEEE International Conference on Semiconductor Electronics (ICSE2018), 15-17 Aug. 2018, Pullman Kuala Lumpur City Centre Hotel & Residence, Kuala Lumpur, Malaysia. (pp. 37-40). 10.1109/SMELEC.2018.8481214
spellingShingle Mohd Chachuli, Siti Amaniah
Hamidon, Mohd Nizar
Mamat @ Mat Nazir, Md Shuhazlly
Ertugrul, Mehmet
Detecting hydrogen using TiO2-B2O3 at different operating temperature
title Detecting hydrogen using TiO2-B2O3 at different operating temperature
title_full Detecting hydrogen using TiO2-B2O3 at different operating temperature
title_fullStr Detecting hydrogen using TiO2-B2O3 at different operating temperature
title_full_unstemmed Detecting hydrogen using TiO2-B2O3 at different operating temperature
title_short Detecting hydrogen using TiO2-B2O3 at different operating temperature
title_sort detecting hydrogen using tio2-b2o3 at different operating temperature
url http://psasir.upm.edu.my/id/eprint/69241/
http://psasir.upm.edu.my/id/eprint/69241/
http://psasir.upm.edu.my/id/eprint/69241/1/Detecting%20hydrogen%20using%20TiO2-B2O3%20at%20different%20operating%20temperature.pdf