Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency

Among the significant renewable resources, wind power has acquired the spotlight, due to the quick development in wind energy conversion technology. However, the penetration level of wind power cannot be increased randomly for maximum power generation primarily because the wind farms cannot always p...

Full description

Bibliographic Details
Main Authors: Al Mentefik, Athraa Iessa Shaaban, Abdul Wahab, Noor Izzri, Mariun, Norman, Hizam, Hashim
Format: Conference or Workshop Item
Language:English
Published: IEEE 2016
Online Access:http://psasir.upm.edu.my/id/eprint/68803/
http://psasir.upm.edu.my/id/eprint/68803/1/Method%20of%20estimating%20the%20maximum%20penetration%20level%20of%20wind%20power%20using%20transient%20frequency%20deviation%20index%20based%20on%20COI%20frequency.pdf
_version_ 1848856230560268288
author Al Mentefik, Athraa Iessa Shaaban
Abdul Wahab, Noor Izzri
Mariun, Norman
Hizam, Hashim
author_facet Al Mentefik, Athraa Iessa Shaaban
Abdul Wahab, Noor Izzri
Mariun, Norman
Hizam, Hashim
author_sort Al Mentefik, Athraa Iessa Shaaban
building UPM Institutional Repository
collection Online Access
description Among the significant renewable resources, wind power has acquired the spotlight, due to the quick development in wind energy conversion technology. However, the penetration level of wind power cannot be increased randomly for maximum power generation primarily because the wind farms cannot always provide a precise amount of power similar to the conventional synchronous generators. Since the frequency is the most affected by the penetration of wind power due to the variable nature and the less inertia of these turbines, it is necessary to estimate the maximum level of wind energy that can maintain a nominal frequency and does not affect the frequency stability of the power system. In this paper, new procedures to determine the maximum wind penetration level using transient frequency deviation index (TFDI) and based on the center of inertia frequency are presented. The results of procedures are established through the dynamic simulation of WSCC 9-bus test system. By using this method, the critical wind level can be assessed while the system preserves acceptable operation frequency.
first_indexed 2025-11-15T11:38:21Z
format Conference or Workshop Item
id upm-68803
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:38:21Z
publishDate 2016
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling upm-688032019-06-10T03:43:58Z http://psasir.upm.edu.my/id/eprint/68803/ Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency Al Mentefik, Athraa Iessa Shaaban Abdul Wahab, Noor Izzri Mariun, Norman Hizam, Hashim Among the significant renewable resources, wind power has acquired the spotlight, due to the quick development in wind energy conversion technology. However, the penetration level of wind power cannot be increased randomly for maximum power generation primarily because the wind farms cannot always provide a precise amount of power similar to the conventional synchronous generators. Since the frequency is the most affected by the penetration of wind power due to the variable nature and the less inertia of these turbines, it is necessary to estimate the maximum level of wind energy that can maintain a nominal frequency and does not affect the frequency stability of the power system. In this paper, new procedures to determine the maximum wind penetration level using transient frequency deviation index (TFDI) and based on the center of inertia frequency are presented. The results of procedures are established through the dynamic simulation of WSCC 9-bus test system. By using this method, the critical wind level can be assessed while the system preserves acceptable operation frequency. IEEE 2016 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/68803/1/Method%20of%20estimating%20the%20maximum%20penetration%20level%20of%20wind%20power%20using%20transient%20frequency%20deviation%20index%20based%20on%20COI%20frequency.pdf Al Mentefik, Athraa Iessa Shaaban and Abdul Wahab, Noor Izzri and Mariun, Norman and Hizam, Hashim (2016) Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency. In: 2016 IEEE 6th International Conference on Power and Energy (PECON2016), 28-29 Nov. 2016, Melaka, Malaysia. (pp. 274-279). 10.1109/PECON.2016.7951572
spellingShingle Al Mentefik, Athraa Iessa Shaaban
Abdul Wahab, Noor Izzri
Mariun, Norman
Hizam, Hashim
Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency
title Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency
title_full Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency
title_fullStr Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency
title_full_unstemmed Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency
title_short Method of estimating the maximum penetration level of wind power using transient frequency deviation index based on COI frequency
title_sort method of estimating the maximum penetration level of wind power using transient frequency deviation index based on coi frequency
url http://psasir.upm.edu.my/id/eprint/68803/
http://psasir.upm.edu.my/id/eprint/68803/
http://psasir.upm.edu.my/id/eprint/68803/1/Method%20of%20estimating%20the%20maximum%20penetration%20level%20of%20wind%20power%20using%20transient%20frequency%20deviation%20index%20based%20on%20COI%20frequency.pdf