A study on lightning protection system - the effect of bending degree of the down conductor

Lightning is one of nature's most powerful and destructive phenomena. Lightning discharges contain awesome amounts of electrical energy and even though a lightning discharge is of a very short duration, but it is a very real cause of damage and destruction. Thus, nothing may exclude from being...

Full description

Bibliographic Details
Main Authors: Mohd Yusoff, Norpisah, Jasni, Jasronita, Manson, Beazley, Ab Kadir, Mohd Zainal Abidin
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/68651/
http://psasir.upm.edu.my/id/eprint/68651/1/A%20study%20on%20lightning%20protection%20system%20-%20the%20effect%20of%20bending%20degree%20of%20the%20down%20conductor.pdf
_version_ 1848856187743764480
author Mohd Yusoff, Norpisah
Jasni, Jasronita
Manson, Beazley
Ab Kadir, Mohd Zainal Abidin
author_facet Mohd Yusoff, Norpisah
Jasni, Jasronita
Manson, Beazley
Ab Kadir, Mohd Zainal Abidin
author_sort Mohd Yusoff, Norpisah
building UPM Institutional Repository
collection Online Access
description Lightning is one of nature's most powerful and destructive phenomena. Lightning discharges contain awesome amounts of electrical energy and even though a lightning discharge is of a very short duration, but it is a very real cause of damage and destruction. Thus, nothing may exclude from being strike by the lightning but lightning protection system could give the reliable protection via its good installation. The major role of lightning protection is to secure a structure from lightning damage by intercepting flashes and then conduct the currents to the ground quickly and safely where its main components are the air termination network, the down conductor and the earth termination. This paper will focus on the effect of bending the down conductor on the electromagnetic of the current flow in the down conductor. Therefore, the main objectives are to investigate and analyses the effect of bending degree of down conductor to the electromagnetic of current flow through the down conductor and to ensure the path for the down conductor to discharge the lightning current to the ground is of low impedance and reduce the probability of damage due to the high impulse lightning current. The overall findings are concluded and discussions are made to explain the overall simulation result at the end of project.
first_indexed 2025-11-15T11:37:40Z
format Conference or Workshop Item
id upm-68651
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:37:40Z
publishDate 2014
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling upm-686512019-06-10T02:45:07Z http://psasir.upm.edu.my/id/eprint/68651/ A study on lightning protection system - the effect of bending degree of the down conductor Mohd Yusoff, Norpisah Jasni, Jasronita Manson, Beazley Ab Kadir, Mohd Zainal Abidin Lightning is one of nature's most powerful and destructive phenomena. Lightning discharges contain awesome amounts of electrical energy and even though a lightning discharge is of a very short duration, but it is a very real cause of damage and destruction. Thus, nothing may exclude from being strike by the lightning but lightning protection system could give the reliable protection via its good installation. The major role of lightning protection is to secure a structure from lightning damage by intercepting flashes and then conduct the currents to the ground quickly and safely where its main components are the air termination network, the down conductor and the earth termination. This paper will focus on the effect of bending the down conductor on the electromagnetic of the current flow in the down conductor. Therefore, the main objectives are to investigate and analyses the effect of bending degree of down conductor to the electromagnetic of current flow through the down conductor and to ensure the path for the down conductor to discharge the lightning current to the ground is of low impedance and reduce the probability of damage due to the high impulse lightning current. The overall findings are concluded and discussions are made to explain the overall simulation result at the end of project. IEEE 2014 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/68651/1/A%20study%20on%20lightning%20protection%20system%20-%20the%20effect%20of%20bending%20degree%20of%20the%20down%20conductor.pdf Mohd Yusoff, Norpisah and Jasni, Jasronita and Manson, Beazley and Ab Kadir, Mohd Zainal Abidin (2014) A study on lightning protection system - the effect of bending degree of the down conductor. In: 2014 International Conference on Lightning Protection (ICLP), 11-18 Oct. 2014, Shanghai, China. (pp. 1739-1745). 10.1109/ICLP.2014.6973410
spellingShingle Mohd Yusoff, Norpisah
Jasni, Jasronita
Manson, Beazley
Ab Kadir, Mohd Zainal Abidin
A study on lightning protection system - the effect of bending degree of the down conductor
title A study on lightning protection system - the effect of bending degree of the down conductor
title_full A study on lightning protection system - the effect of bending degree of the down conductor
title_fullStr A study on lightning protection system - the effect of bending degree of the down conductor
title_full_unstemmed A study on lightning protection system - the effect of bending degree of the down conductor
title_short A study on lightning protection system - the effect of bending degree of the down conductor
title_sort study on lightning protection system - the effect of bending degree of the down conductor
url http://psasir.upm.edu.my/id/eprint/68651/
http://psasir.upm.edu.my/id/eprint/68651/
http://psasir.upm.edu.my/id/eprint/68651/1/A%20study%20on%20lightning%20protection%20system%20-%20the%20effect%20of%20bending%20degree%20of%20the%20down%20conductor.pdf