Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia
The role of Positron Emission Tomography/Computed Tomography (PET/CT) modalities is becoming more important concomitantly with the increase of oncology cases in Malaysia. Thus, it is the perfect time to perform a study to standardise the PET/CT image quality in Malaysia. This study aimed to compa...
| Main Author: | |
|---|---|
| Format: | Thesis |
| Language: | English |
| Published: |
2017
|
| Subjects: | |
| Online Access: | http://psasir.upm.edu.my/id/eprint/68328/ http://psasir.upm.edu.my/id/eprint/68328/1/FPSK%28m%29%202018%208.pdf |
| _version_ | 1848856095805669376 |
|---|---|
| author | Hanafi, Muhammad Hafiz |
| author_facet | Hanafi, Muhammad Hafiz |
| author_sort | Hanafi, Muhammad Hafiz |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | The role of Positron Emission Tomography/Computed Tomography (PET/CT)
modalities is becoming more important concomitantly with the increase of
oncology cases in Malaysia. Thus, it is the perfect time to perform a study to
standardise the PET/CT image quality in Malaysia. This study aimed to compare
the quantification of image quality of PET/CT with a standardised uptake value
(SUV) parameter. In general, this study was carried out with the purpose of
identifying the standardisation of quantification of standardised uptake value,
SUVcontrolled for 18F-FDG PET between two independent PET modalities at two
different institutions.
The analysis was done on the SUVcontrolled of technical techniques (PET phantom)
as a control standard for the validation of the PET-CT images of selected subjects
with Fasting Blood Glucose index as the adjusted index to synchronise the two
independent data sets. It was found that the SUVcontrolled was a potential
conversion marker to validate the in vivo standardisation techniques for the two
independent PET/CT modality systems based on the reference standard of the
matched FBS and the in vitro 18F-FDG phantom. This study confirmed that the
two independent PET modalities at paired-centre could potentially be
standardised on the independent image quality based on the SUVmax
quantification as the two independent measured were insignificantly different. |
| first_indexed | 2025-11-15T11:36:13Z |
| format | Thesis |
| id | upm-68328 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T11:36:13Z |
| publishDate | 2017 |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-683282025-06-04T04:56:13Z http://psasir.upm.edu.my/id/eprint/68328/ Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia Hanafi, Muhammad Hafiz The role of Positron Emission Tomography/Computed Tomography (PET/CT) modalities is becoming more important concomitantly with the increase of oncology cases in Malaysia. Thus, it is the perfect time to perform a study to standardise the PET/CT image quality in Malaysia. This study aimed to compare the quantification of image quality of PET/CT with a standardised uptake value (SUV) parameter. In general, this study was carried out with the purpose of identifying the standardisation of quantification of standardised uptake value, SUVcontrolled for 18F-FDG PET between two independent PET modalities at two different institutions. The analysis was done on the SUVcontrolled of technical techniques (PET phantom) as a control standard for the validation of the PET-CT images of selected subjects with Fasting Blood Glucose index as the adjusted index to synchronise the two independent data sets. It was found that the SUVcontrolled was a potential conversion marker to validate the in vivo standardisation techniques for the two independent PET/CT modality systems based on the reference standard of the matched FBS and the in vitro 18F-FDG phantom. This study confirmed that the two independent PET modalities at paired-centre could potentially be standardised on the independent image quality based on the SUVmax quantification as the two independent measured were insignificantly different. 2017-11 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/68328/1/FPSK%28m%29%202018%208.pdf Hanafi, Muhammad Hafiz (2017) Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia. Masters thesis, Universiti Putra Malaysia. Positron-Emission Tomography - Malaysia Fluorodeoxyglucose F18 |
| spellingShingle | Positron-Emission Tomography - Malaysia Fluorodeoxyglucose F18 Hanafi, Muhammad Hafiz Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia |
| title | Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia |
| title_full | Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia |
| title_fullStr | Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia |
| title_full_unstemmed | Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia |
| title_short | Quantification of standardised uptake value for ¹⁸F-FDG positron emission tomography in Malaysia |
| title_sort | quantification of standardised uptake value for ¹⁸f-fdg positron emission tomography in malaysia |
| topic | Positron-Emission Tomography - Malaysia Fluorodeoxyglucose F18 |
| url | http://psasir.upm.edu.my/id/eprint/68328/ http://psasir.upm.edu.my/id/eprint/68328/1/FPSK%28m%29%202018%208.pdf |