Development of an in-sole plantar pressure measurement device
This paper describes the design and development of an In-sole Plantar Pressure Device (IPPD) to measure underfoot pressure. Knowledge on underfoot pressure is important for different purposes. It is essential for doctors and clinicians to have information about underfoot pressure to enable them to d...
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Conference or Workshop Item |
| Language: | English |
| Published: |
IEEE
2018
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/68152/ http://psasir.upm.edu.my/id/eprint/68152/1/Development%20of%20an%20in-sole%20plantar%20pressure%20measurement%20device.pdf |
| _version_ | 1848856045844168704 |
|---|---|
| author | Hussein, O. Wan Hasan, Wan Zuha Che Soh, Azura Jafaar, H. Harun @ Ramli, Hafiz Rashidi Rahman, F. A. Ang, Swee Peng Abdul Hamid, Zainidi |
| author_facet | Hussein, O. Wan Hasan, Wan Zuha Che Soh, Azura Jafaar, H. Harun @ Ramli, Hafiz Rashidi Rahman, F. A. Ang, Swee Peng Abdul Hamid, Zainidi |
| author_sort | Hussein, O. |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | This paper describes the design and development of an In-sole Plantar Pressure Device (IPPD) to measure underfoot pressure. Knowledge on underfoot pressure is important for different purposes. It is essential for doctors and clinicians to have information about underfoot pressure to enable them to diagnose foot problems. Currently, underfoot pressure ranges have not been effectively established, and there is insufficient information about the minimum and maximum values of underfoot pressure. Likewise, constraints with regard to the implementation of insole systems still persist and are represented by the need to put a spacer on the sensor during measurements, and the problem of sensor parameters changing after the calibration. These challenges are addressed in this work and preliminary results or performance of the proposed device are then presented. |
| first_indexed | 2025-11-15T11:35:25Z |
| format | Conference or Workshop Item |
| id | upm-68152 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T11:35:25Z |
| publishDate | 2018 |
| publisher | IEEE |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-681522019-05-09T01:44:36Z http://psasir.upm.edu.my/id/eprint/68152/ Development of an in-sole plantar pressure measurement device Hussein, O. Wan Hasan, Wan Zuha Che Soh, Azura Jafaar, H. Harun @ Ramli, Hafiz Rashidi Rahman, F. A. Ang, Swee Peng Abdul Hamid, Zainidi This paper describes the design and development of an In-sole Plantar Pressure Device (IPPD) to measure underfoot pressure. Knowledge on underfoot pressure is important for different purposes. It is essential for doctors and clinicians to have information about underfoot pressure to enable them to diagnose foot problems. Currently, underfoot pressure ranges have not been effectively established, and there is insufficient information about the minimum and maximum values of underfoot pressure. Likewise, constraints with regard to the implementation of insole systems still persist and are represented by the need to put a spacer on the sensor during measurements, and the problem of sensor parameters changing after the calibration. These challenges are addressed in this work and preliminary results or performance of the proposed device are then presented. IEEE 2018 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/68152/1/Development%20of%20an%20in-sole%20plantar%20pressure%20measurement%20device.pdf Hussein, O. and Wan Hasan, Wan Zuha and Che Soh, Azura and Jafaar, H. and Harun @ Ramli, Hafiz Rashidi and Rahman, F. A. and Ang, Swee Peng and Abdul Hamid, Zainidi (2018) Development of an in-sole plantar pressure measurement device. In: 2018 IEEE 5th International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA 2018), 28-30 Nov. 2018, Songkla, Thailand. . 10.1109/ICSIMA.2018.8688798 |
| spellingShingle | Hussein, O. Wan Hasan, Wan Zuha Che Soh, Azura Jafaar, H. Harun @ Ramli, Hafiz Rashidi Rahman, F. A. Ang, Swee Peng Abdul Hamid, Zainidi Development of an in-sole plantar pressure measurement device |
| title | Development of an in-sole plantar pressure measurement device |
| title_full | Development of an in-sole plantar pressure measurement device |
| title_fullStr | Development of an in-sole plantar pressure measurement device |
| title_full_unstemmed | Development of an in-sole plantar pressure measurement device |
| title_short | Development of an in-sole plantar pressure measurement device |
| title_sort | development of an in-sole plantar pressure measurement device |
| url | http://psasir.upm.edu.my/id/eprint/68152/ http://psasir.upm.edu.my/id/eprint/68152/ http://psasir.upm.edu.my/id/eprint/68152/1/Development%20of%20an%20in-sole%20plantar%20pressure%20measurement%20device.pdf |