Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope

Measurement of discharge rates of fluids and solids is an essential requirement in industrial systems. Industrial processes worldwide are progressively recognizing the value of industrial radiotracer application in studying the operation of the on-line plant. Radiotracer techniques are widely used f...

Full description

Bibliographic Details
Main Authors: Mohd Yunos, Mohd Amirul Syafiq, Hussain, Siti Aslina, Sipaun, Susan
Format: Conference or Workshop Item
Language:English
Published: 2017
Online Access:http://psasir.upm.edu.my/id/eprint/64377/
http://psasir.upm.edu.my/id/eprint/64377/1/ENG%20%26%20New%20Tech%20Oral%20111117%2016.pdf
_version_ 1848854985122512896
author Mohd Yunos, Mohd Amirul Syafiq
Hussain, Siti Aslina
Sipaun, Susan
author_facet Mohd Yunos, Mohd Amirul Syafiq
Hussain, Siti Aslina
Sipaun, Susan
author_sort Mohd Yunos, Mohd Amirul Syafiq
building UPM Institutional Repository
collection Online Access
description Measurement of discharge rates of fluids and solids is an essential requirement in industrial systems. Industrial processes worldwide are progressively recognizing the value of industrial radiotracer application in studying the operation of the on-line plant. Radiotracer techniques are widely used for measurement of fluids/solids in situations where conventional techniques cannot be applied. This present report describes the flow rate measurement using radioisotope technique using unsealed radioactive source to calibrate the installed flowmeters and to measure the flow rate in systems, which does not influence the on-line process. An investigation was performed by the injection of a radiotracer inside the multiphase flow rig system to provide fluid flow rate information. In this study, the multiphase rig was filled up with mixed oil-water, and the Coriolis flowmeter was installed in the system for efficiency validation. Cs-137/Ba-137m radioisotope generators were used to prepare the radiotracer and Ba-137m radioisotopes having activity about 0.2 mCi. The peak to peak method was applied for the radiotracer techniques. The average volumetric flow rate of multiphase flow rig was measured to be 6.43 m3/h. This study has proved that Coriolis flowmeter is not functioning in good condition due to different flow rate value from the experimental works and suggested to be recalibrated or replace.
first_indexed 2025-11-15T11:18:34Z
format Conference or Workshop Item
id upm-64377
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:18:34Z
publishDate 2017
recordtype eprints
repository_type Digital Repository
spelling upm-643772018-07-05T09:23:17Z http://psasir.upm.edu.my/id/eprint/64377/ Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope Mohd Yunos, Mohd Amirul Syafiq Hussain, Siti Aslina Sipaun, Susan Measurement of discharge rates of fluids and solids is an essential requirement in industrial systems. Industrial processes worldwide are progressively recognizing the value of industrial radiotracer application in studying the operation of the on-line plant. Radiotracer techniques are widely used for measurement of fluids/solids in situations where conventional techniques cannot be applied. This present report describes the flow rate measurement using radioisotope technique using unsealed radioactive source to calibrate the installed flowmeters and to measure the flow rate in systems, which does not influence the on-line process. An investigation was performed by the injection of a radiotracer inside the multiphase flow rig system to provide fluid flow rate information. In this study, the multiphase rig was filled up with mixed oil-water, and the Coriolis flowmeter was installed in the system for efficiency validation. Cs-137/Ba-137m radioisotope generators were used to prepare the radiotracer and Ba-137m radioisotopes having activity about 0.2 mCi. The peak to peak method was applied for the radiotracer techniques. The average volumetric flow rate of multiphase flow rig was measured to be 6.43 m3/h. This study has proved that Coriolis flowmeter is not functioning in good condition due to different flow rate value from the experimental works and suggested to be recalibrated or replace. 2017 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/64377/1/ENG%20%26%20New%20Tech%20Oral%20111117%2016.pdf Mohd Yunos, Mohd Amirul Syafiq and Hussain, Siti Aslina and Sipaun, Susan (2017) Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope. In: 5th International Symposium on Applied Engineering and Sciences (SAES2017), 14-15 Nov. 2017, Universiti Putra Malaysia. (p. 16).
spellingShingle Mohd Yunos, Mohd Amirul Syafiq
Hussain, Siti Aslina
Sipaun, Susan
Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope
title Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope
title_full Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope
title_fullStr Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope
title_full_unstemmed Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope
title_short Industrial radiotracer application for flow rate measurement using Ba-137m radioisotope
title_sort industrial radiotracer application for flow rate measurement using ba-137m radioisotope
url http://psasir.upm.edu.my/id/eprint/64377/
http://psasir.upm.edu.my/id/eprint/64377/1/ENG%20%26%20New%20Tech%20Oral%20111117%2016.pdf