Voltammetric determination of dopamine mediated by nanoparticle WO3/MWCNT modified glassy carbon electrode
Chemically-modified electrode fabricated by mechanical attachment of multi-walled carbon nanotubes/tungsten oxide (MWCNTs/WO3) in the electrocatalytic study of dopamine was investigated. The MWCNTs/WO3 nanocomposite has been characterized using voltammetric techniques of cyclic voltammetry, chronoam...
| Main Authors: | Lim, Alvin Teik Zheng, Ando, Yoshito, Zawawi, Ruzniza Mohd |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Research India Publications
2017
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/63696/ http://psasir.upm.edu.my/id/eprint/63696/1/Voltammetric%20determination%20of%20dopamine%20mediated%20by%20nanoparticle%20WO3.pdf |
Similar Items
Voltammetric detection of Mn(II) in blood sample at C60 and MWCNT modified glassy carbon electrodes
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
Voltammetric studies and characterizations of biocompatible graphene/collagen nanocomposite-modified glassy carbon electrode towards enantio-recognition of chiral molecules
by: Kasinathan, Bavani, et al.
Published: (2015)
by: Kasinathan, Bavani, et al.
Published: (2015)
Voltammetric studies of nano zirconium dioxide/carbon nanotubes/chitosan-modified glassy carbon electrodes.
by: Mohd Maamor, Nor Amirah, et al.
Published: (2009)
by: Mohd Maamor, Nor Amirah, et al.
Published: (2009)
Electrochemical oxidation of ascorbic acid using MgB2-MWCNT modified glassy carbon electrode
by: Banan, Darlene, et al.
Published: (2013)
by: Banan, Darlene, et al.
Published: (2013)
Voltammetric detection of potassium ferricyanide mediated by multi walled carbon nanotube titanium dioxide composite modified glassy carbon electrode.
by: Perenlei, Ganchimeg, et al.
Published: (2011)
by: Perenlei, Ganchimeg, et al.
Published: (2011)
Voltammetric oxidation of ascorbic acid mediated by multi-walled carbon nanotubes/titanium dioxide composite modified glassy carbon electrode.
by: Perenlei, Ganchimeg, et al.
Published: (2011)
by: Perenlei, Ganchimeg, et al.
Published: (2011)
Electrocatalytic oxidation of ascorbic acid mediated by lithium doped microparticles Bi2O3/MWCNT modified glassy carbon electrode
by: Zidan, Mohammed, et al.
Published: (2010)
by: Zidan, Mohammed, et al.
Published: (2010)
Electrochemical oxidation of paracetamol mediated by nanoparticles bismuth oxide modified glassy carbon electrode.
by: Mohammed Zidan,, et al.
Published: (2011)
by: Mohammed Zidan,, et al.
Published: (2011)
Electrochemical oxidation of ascorbic acid mediated by Bi₂0₃ nanoparticles modified glassy carbon electrode
by: Zidan, Mohammed, et al.
Published: (2009)
by: Zidan, Mohammed, et al.
Published: (2009)
Electrochemical detection of ascorbic acid at MɡB₂- MWCNT and MɡB₂ /PEDOT hybrid modified glassy carbon electrodes
by: Banan, Darlene
Published: (2017)
by: Banan, Darlene
Published: (2017)
Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
by: Feng, Zhou, et al.
Published: (2024)
by: Feng, Zhou, et al.
Published: (2024)
Voltammetric determination of hydroquinone, catechol, and resorcinol by using a glassy carbon electrode modified with electrochemically reduced graphene oxide-poly (Eriochrome Black T) and gold nanoparticles
by: Alshik Edris, Nusiba Mohammed Modawe, et al.
Published: (2019)
by: Alshik Edris, Nusiba Mohammed Modawe, et al.
Published: (2019)
Voltammetric oxidation of potassium thiocyanate using ErBa2Cu3O7 modified glassy carbon electrode.
by: Mohammed Zidan,, et al.
Published: (2013)
by: Mohammed Zidan,, et al.
Published: (2013)
Electrochemical reduced graphene oxide-poly(eriochrome black T)/gold nanoparticles modified glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
by: Alshik Edris, Nusiba Mohammed Modawe, et al.
Published: (2018)
by: Alshik Edris, Nusiba Mohammed Modawe, et al.
Published: (2018)
Hematite nanoparticles-modified electrode based electrochemical sensing platform for dopamine
by: Kamali, Khosro Zangeneh, et al.
Published: (2014)
by: Kamali, Khosro Zangeneh, et al.
Published: (2014)
Simultaneous electrochemical detection of dopamine and ascorbic acid using iron oxide/reduced graphene oxide modified glassy carbon electrode
by: Teo, Peik See, et al.
Published: (2014)
by: Teo, Peik See, et al.
Published: (2014)
Electrochemical oxidation of paracetamol mediated by zinc oxide modified glassy carbon electrode
by: Mohammed Zidan,, et al.
Published: (2010)
by: Mohammed Zidan,, et al.
Published: (2010)
Fabrication and voltammetric characterization of deoxyribonucleic acid sensor based on nano-titanium dioxide/carbon nanotubes/chitosan-modified glassy
carbon electrode
by: Mohd Maamor, Nor Amirah, et al.
Published: (2009)
by: Mohd Maamor, Nor Amirah, et al.
Published: (2009)
Voltammetry detection of ascorbic acid at glassy carbon
electrode modified by single-walled carbon nanotube/zinc
oxide.
by: Koh, Sing Ngai, et al.
Published: (2013)
by: Koh, Sing Ngai, et al.
Published: (2013)
Electrochemical redox of Cd(II) mediated by activated carbon modified glassy carbon electrode.
by: Tan, Wee Tee, et al.
Published: (2010)
by: Tan, Wee Tee, et al.
Published: (2010)
Electrochemical redox of Hg2+ mediated by activated carbon modified glassy carbon electrode.
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
Electrochemical reduction of Mn(II) mediated by C60/Li+ modified glassy carbon electrode.
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
Electrocatalytic oxidation of ascorbic acid mediated by ZnO microcrystalline modified glassy carbon electrode.
by: Tan, Wee Tee, et al.
Published: (2010)
by: Tan, Wee Tee, et al.
Published: (2010)
Voltammetric determination of palmitic acid by electrode modified with reduced graphene oxide and gold nanoparticles composite
by: Chin, Boon Ching
Published: (2020)
by: Chin, Boon Ching
Published: (2020)
Single-walled carbon nanotube/tungsten-modified glassy carbon electrode as a novel sensor for the electrochemical determination of ascorbic acid
by: Ngai, Koh Sing, et al.
Published: (2015)
by: Ngai, Koh Sing, et al.
Published: (2015)
Fabrication and Characterization of DNA Sensors from Metal Oxides Nanoparticles and Chitosan-Modified Glassy Carbon Electrodes
by: Mohd Maamor, Nor Amirah
Published: (2011)
by: Mohd Maamor, Nor Amirah
Published: (2011)
Voltammetric determination of human papillomavirus 16 DNA by using interdigitated electrodes modified with titanium dioxide nanoparticles
by: Parmin, Nor Azizah, et al.
Published: (2019)
by: Parmin, Nor Azizah, et al.
Published: (2019)
Electrocatalytic oxidation of paracetamol mediated by lithium doped microparticles Bi2O3/MWCNT modified electrode.
by: Mohammed Zidan,, et al.
Published: (2011)
by: Mohammed Zidan,, et al.
Published: (2011)
Electrochemical oxidation of ascorbic acid mediated by Bi2O3 microparticles modified glassy carbon electrode.
by: Mohammed Zidan,, et al.
Published: (2011)
by: Mohammed Zidan,, et al.
Published: (2011)
Determination of ascorbic acid in the multivitamin by differential pulse anodic
stripping voltammetric technique at a glassy carbon electrode / Siti Norbaitina Shaari
by: Shaari, Siti Norbaitina
Published: (2017)
by: Shaari, Siti Norbaitina
Published: (2017)
Voltammetric determination of palmitic acid by electrode modified with reduced graphene oxide
by: Chin, Boon Ching, et al.
Published: (2021)
by: Chin, Boon Ching, et al.
Published: (2021)
Simultaneous determination of organic analytes by reduced graphene oxide-azo dyes/gold nanoparticles modified glassy carbon electrode
by: Alshik Edris, Nusiba Mohammed Modawe
Published: (2019)
by: Alshik Edris, Nusiba Mohammed Modawe
Published: (2019)
Electrochemical detection of Mn(II) and Cd(II) mediated by carbon nanotubes and nanotubes/Li+ modified glassy carbon electrode.
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
by: Radhi, Muhammed Mizher, et al.
Published: (2010)
Differential pulse anodic stripping voltammetric
(dpasv) technique for reactive black 5 analysis at glassy carbon electrode / Nur Aqilah Abdul Rahman
by: Abdul Rahman, Nur Aqilah
Published: (2017)
by: Abdul Rahman, Nur Aqilah
Published: (2017)
Cyclic and pulse voltammetric study of dopamine at the interface between two immiscible electrolyte solutions
by: Beni, V., et al.
Published: (2005)
by: Beni, V., et al.
Published: (2005)
Ascorbic acid determination in natural and commercial fruit juices by differential pulse anodic
stripping voltammetric technique at a glassy carbon electrode / Zaihasra Razis
by: Razis, Zaihasra
Published: (2017)
by: Razis, Zaihasra
Published: (2017)
Electrochemical analysis of carbon nanotubes/titanium dioxide composite modified glassy carbon electrode
by: Perenlei, Ganchimeg
Published: (2010)
by: Perenlei, Ganchimeg
Published: (2010)
Simultaneous electrochemical determination of dopamine, uric acid and ascorbic acid using palladium nanoparticle-loaded carbon nanofibers modified electrode
by: Huang, J., et al.
Published: (2008)
by: Huang, J., et al.
Published: (2008)
Electrochemical oxidation/reduction of selected compounds mediated by indium tin oxide doped with lithium and glassy carbon electrode modified with tin dioxide
by: Yeo, May Ching
Published: (2012)
by: Yeo, May Ching
Published: (2012)
A glassy carbon electrode modified with tailored nanostructures of cobalt oxide for oxygen reduction reaction
by: M. M., Shahid, et al.
Published: (2020)
by: M. M., Shahid, et al.
Published: (2020)
Similar Items
-
Voltammetric detection of Mn(II) in blood sample at C60 and MWCNT modified glassy carbon electrodes
by: Radhi, Muhammed Mizher, et al.
Published: (2010) -
Voltammetric studies and characterizations of biocompatible graphene/collagen nanocomposite-modified glassy carbon electrode towards enantio-recognition of chiral molecules
by: Kasinathan, Bavani, et al.
Published: (2015) -
Voltammetric studies of nano zirconium dioxide/carbon nanotubes/chitosan-modified glassy carbon electrodes.
by: Mohd Maamor, Nor Amirah, et al.
Published: (2009) -
Electrochemical oxidation of ascorbic acid using MgB2-MWCNT modified glassy carbon electrode
by: Banan, Darlene, et al.
Published: (2013) -
Voltammetric detection of potassium ferricyanide mediated by multi walled carbon nanotube titanium dioxide composite modified glassy carbon electrode.
by: Perenlei, Ganchimeg, et al.
Published: (2011)