Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids

A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by...

Full description

Bibliographic Details
Main Authors: Kamaruzaman, Sazlinda, Sanagi, Mohd Marsin, Yahaya, Noorfatimah, Wan Ibrahim, Wan Aini, Endud, Salasiah, Wan Ibrahim, Wan Nazihah
Format: Article
Language:English
Published: Wiley-VCH Verlag 2017
Online Access:http://psasir.upm.edu.my/id/eprint/62328/
http://psasir.upm.edu.my/id/eprint/62328/1/Magnetic%20micro-solid-phase%20extraction%20based%20on%20magnetite-MCM-41%20with%20gas%20chromatography-mass%20spectrometry%20for%20the%20determination%20of%20antidepressant%20drugs%20in%20biological%20fluids.pdf
_version_ 1848854608297852928
author Kamaruzaman, Sazlinda
Sanagi, Mohd Marsin
Yahaya, Noorfatimah
Wan Ibrahim, Wan Aini
Endud, Salasiah
Wan Ibrahim, Wan Nazihah
author_facet Kamaruzaman, Sazlinda
Sanagi, Mohd Marsin
Yahaya, Noorfatimah
Wan Ibrahim, Wan Aini
Endud, Salasiah
Wan Ibrahim, Wan Nazihah
author_sort Kamaruzaman, Sazlinda
building UPM Institutional Repository
collection Online Access
description A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 μg/L (r2 = 0.996-0.999). Good limits of detection (0.008-0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.
first_indexed 2025-11-15T11:12:34Z
format Article
id upm-62328
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:12:34Z
publishDate 2017
publisher Wiley-VCH Verlag
recordtype eprints
repository_type Digital Repository
spelling upm-623282022-05-20T01:31:56Z http://psasir.upm.edu.my/id/eprint/62328/ Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids Kamaruzaman, Sazlinda Sanagi, Mohd Marsin Yahaya, Noorfatimah Wan Ibrahim, Wan Aini Endud, Salasiah Wan Ibrahim, Wan Nazihah A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 μg/L (r2 = 0.996-0.999). Good limits of detection (0.008-0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples. Wiley-VCH Verlag 2017-11 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/62328/1/Magnetic%20micro-solid-phase%20extraction%20based%20on%20magnetite-MCM-41%20with%20gas%20chromatography-mass%20spectrometry%20for%20the%20determination%20of%20antidepressant%20drugs%20in%20biological%20fluids.pdf Kamaruzaman, Sazlinda and Sanagi, Mohd Marsin and Yahaya, Noorfatimah and Wan Ibrahim, Wan Aini and Endud, Salasiah and Wan Ibrahim, Wan Nazihah (2017) Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids. Journal of Separation Science, 40 (21). 4222 - 4232. ISSN 1615-9306; ESSN: 1615-9314 https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.201700549 10.1002/jssc.201700549
spellingShingle Kamaruzaman, Sazlinda
Sanagi, Mohd Marsin
Yahaya, Noorfatimah
Wan Ibrahim, Wan Aini
Endud, Salasiah
Wan Ibrahim, Wan Nazihah
Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
title Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
title_full Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
title_fullStr Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
title_full_unstemmed Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
title_short Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
title_sort magnetic micro-solid-phase extraction based on magnetite-mcm-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids
url http://psasir.upm.edu.my/id/eprint/62328/
http://psasir.upm.edu.my/id/eprint/62328/
http://psasir.upm.edu.my/id/eprint/62328/
http://psasir.upm.edu.my/id/eprint/62328/1/Magnetic%20micro-solid-phase%20extraction%20based%20on%20magnetite-MCM-41%20with%20gas%20chromatography-mass%20spectrometry%20for%20the%20determination%20of%20antidepressant%20drugs%20in%20biological%20fluids.pdf