The conventional billing system uses a lot of manpower and cost of utilities especially on technical issues and billing process. Besides, the consumers are passive participants and unaware with their energy consumptions discipline. The network design for both energy and data transfer is one-way flow...

Full description

Bibliographic Details
Main Authors: Ab. Halim, Haizum Hanim, Mariun, Norman, Othman, Mohammad Lutfi, Mailah, Nashiren Farzilah
Format: Article
Language:English
Published: Malaysian Society for Engineering & Technology (MySET) 2017
Online Access:http://psasir.upm.edu.my/id/eprint/60781/
http://psasir.upm.edu.my/id/eprint/60781/1/Advanced%20metering%20infrastructure%20and%20an%20implementation%20in%20Malaysia.pdf
_version_ 1848854272876216320
author Ab. Halim, Haizum Hanim
Mariun, Norman
Othman, Mohammad Lutfi
Mailah, Nashiren Farzilah
author_facet Ab. Halim, Haizum Hanim
Mariun, Norman
Othman, Mohammad Lutfi
Mailah, Nashiren Farzilah
author_sort Ab. Halim, Haizum Hanim
building UPM Institutional Repository
collection Online Access
description The conventional billing system uses a lot of manpower and cost of utilities especially on technical issues and billing process. Besides, the consumers are passive participants and unaware with their energy consumptions discipline. The network design for both energy and data transfer is one-way flow with limited information exchange process for utilities, and thus obviously does not meet the expectation of consumers. AMI is introduced to perform a system that is capable to operate smoothly for better monitoring and billing system. Malaysia has an ongoing pilot test project on the smart meter system and the main purpose of the project is to test the reliability of the meter system and the effectiveness of different types of communication technology and also the cost effectiveness. Based on the report, the network issues are the main problem in the pilot test that affected the data transfer process. As an example, data delays due to weak RF links, poor GPRS coverage and LAN interface on PLC DCU were down. Poor networking has caused delays and backlog data stored in the meter, hence, it is contributing to overload data issues because data is too big to be pushed to HES through GPRS network. It can be concluded that the network issues contribute to the expensive maintenances and complex processes during the pilot test.
first_indexed 2025-11-15T11:07:14Z
format Article
id upm-60781
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T11:07:14Z
publishDate 2017
publisher Malaysian Society for Engineering & Technology (MySET)
recordtype eprints
repository_type Digital Repository
spelling upm-607812022-05-25T04:22:51Z http://psasir.upm.edu.my/id/eprint/60781/ Advanced metering infrastructure and an implementation in Malaysia Ab. Halim, Haizum Hanim Mariun, Norman Othman, Mohammad Lutfi Mailah, Nashiren Farzilah The conventional billing system uses a lot of manpower and cost of utilities especially on technical issues and billing process. Besides, the consumers are passive participants and unaware with their energy consumptions discipline. The network design for both energy and data transfer is one-way flow with limited information exchange process for utilities, and thus obviously does not meet the expectation of consumers. AMI is introduced to perform a system that is capable to operate smoothly for better monitoring and billing system. Malaysia has an ongoing pilot test project on the smart meter system and the main purpose of the project is to test the reliability of the meter system and the effectiveness of different types of communication technology and also the cost effectiveness. Based on the report, the network issues are the main problem in the pilot test that affected the data transfer process. As an example, data delays due to weak RF links, poor GPRS coverage and LAN interface on PLC DCU were down. Poor networking has caused delays and backlog data stored in the meter, hence, it is contributing to overload data issues because data is too big to be pushed to HES through GPRS network. It can be concluded that the network issues contribute to the expensive maintenances and complex processes during the pilot test. Malaysian Society for Engineering & Technology (MySET) 2017 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/60781/1/Advanced%20metering%20infrastructure%20and%20an%20implementation%20in%20Malaysia.pdf Ab. Halim, Haizum Hanim and Mariun, Norman and Othman, Mohammad Lutfi and Mailah, Nashiren Farzilah (2017) Advanced metering infrastructure and an implementation in Malaysia. FEIIC International Journal of Engineering and Technology, 14 (1). 40 - 45. ISSN 1823-1039
spellingShingle Ab. Halim, Haizum Hanim
Mariun, Norman
Othman, Mohammad Lutfi
Mailah, Nashiren Farzilah
Advanced metering infrastructure and an implementation in Malaysia
title Advanced metering infrastructure and an implementation in Malaysia
title_full Advanced metering infrastructure and an implementation in Malaysia
title_fullStr Advanced metering infrastructure and an implementation in Malaysia
title_full_unstemmed Advanced metering infrastructure and an implementation in Malaysia
title_short Advanced metering infrastructure and an implementation in Malaysia
title_sort advanced metering infrastructure and an implementation in malaysia
url http://psasir.upm.edu.my/id/eprint/60781/
http://psasir.upm.edu.my/id/eprint/60781/1/Advanced%20metering%20infrastructure%20and%20an%20implementation%20in%20Malaysia.pdf