A corrective action scheme for contingency monitoring of transmission line overloading
Special Protection Schemes (SPSs), are corrective action schemes that are designed to protect power systems against severe contingency conditions. In planning of SPSs, protecting transmission network from overloading issue due to critical situations has become a serious challenge which needs to be t...
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universiti Putra Malaysia Press
2017
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/55828/ http://psasir.upm.edu.my/id/eprint/55828/1/15-JTS%28S%29-0091-2016-4thProof.pdf |
| _version_ | 1848852911502655488 |
|---|---|
| author | Othman, Mohammad Lutfi Hadi, Mahmood Khalid Abdul Wahab, Noor Izzri |
| author_facet | Othman, Mohammad Lutfi Hadi, Mahmood Khalid Abdul Wahab, Noor Izzri |
| author_sort | Othman, Mohammad Lutfi |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | Special Protection Schemes (SPSs), are corrective action schemes that are designed to protect power systems against severe contingency conditions. In planning of SPSs, protecting transmission network from overloading issue due to critical situations has become a serious challenge which needs to be taken into account. In this paper, a Special Protection and Control Scheme (SPCS) based on Differential Evolution (DE) algorithm for optimal generation rescheduling has been applied to mitigate the transmission line overloading in system contingency conditions. The N-1 contingency has been performed for different single line outages under base and increased load in which generation rescheduling strategy has been undertaken to overcome the overloading problem. Simulation results are presented for both pre-and post system emergency situations. The IEEE 30-bus test system was utilised in order to validate the effectiveness of the proposed method. |
| first_indexed | 2025-11-15T10:45:36Z |
| format | Article |
| id | upm-55828 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T10:45:36Z |
| publishDate | 2017 |
| publisher | Universiti Putra Malaysia Press |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-558282017-07-05T04:57:29Z http://psasir.upm.edu.my/id/eprint/55828/ A corrective action scheme for contingency monitoring of transmission line overloading Othman, Mohammad Lutfi Hadi, Mahmood Khalid Abdul Wahab, Noor Izzri Special Protection Schemes (SPSs), are corrective action schemes that are designed to protect power systems against severe contingency conditions. In planning of SPSs, protecting transmission network from overloading issue due to critical situations has become a serious challenge which needs to be taken into account. In this paper, a Special Protection and Control Scheme (SPCS) based on Differential Evolution (DE) algorithm for optimal generation rescheduling has been applied to mitigate the transmission line overloading in system contingency conditions. The N-1 contingency has been performed for different single line outages under base and increased load in which generation rescheduling strategy has been undertaken to overcome the overloading problem. Simulation results are presented for both pre-and post system emergency situations. The IEEE 30-bus test system was utilised in order to validate the effectiveness of the proposed method. Universiti Putra Malaysia Press 2017 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55828/1/15-JTS%28S%29-0091-2016-4thProof.pdf Othman, Mohammad Lutfi and Hadi, Mahmood Khalid and Abdul Wahab, Noor Izzri (2017) A corrective action scheme for contingency monitoring of transmission line overloading. Pertanika Journal of Science & Technology, 25 (spec. Jan.). pp. 129-138. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Jan.%202017/15-JTS(S)-0091-2016-4thProof.pdf |
| spellingShingle | Othman, Mohammad Lutfi Hadi, Mahmood Khalid Abdul Wahab, Noor Izzri A corrective action scheme for contingency monitoring of transmission line overloading |
| title | A corrective action scheme for contingency monitoring of transmission line overloading |
| title_full | A corrective action scheme for contingency monitoring of transmission line overloading |
| title_fullStr | A corrective action scheme for contingency monitoring of transmission line overloading |
| title_full_unstemmed | A corrective action scheme for contingency monitoring of transmission line overloading |
| title_short | A corrective action scheme for contingency monitoring of transmission line overloading |
| title_sort | corrective action scheme for contingency monitoring of transmission line overloading |
| url | http://psasir.upm.edu.my/id/eprint/55828/ http://psasir.upm.edu.my/id/eprint/55828/ http://psasir.upm.edu.my/id/eprint/55828/1/15-JTS%28S%29-0091-2016-4thProof.pdf |