A corrective action scheme for contingency monitoring of transmission line overloading

Special Protection Schemes (SPSs), are corrective action schemes that are designed to protect power systems against severe contingency conditions. In planning of SPSs, protecting transmission network from overloading issue due to critical situations has become a serious challenge which needs to be t...

Full description

Bibliographic Details
Main Authors: Othman, Mohammad Lutfi, Hadi, Mahmood Khalid, Abdul Wahab, Noor Izzri
Format: Article
Language:English
Published: Universiti Putra Malaysia Press 2017
Online Access:http://psasir.upm.edu.my/id/eprint/55828/
http://psasir.upm.edu.my/id/eprint/55828/1/15-JTS%28S%29-0091-2016-4thProof.pdf
_version_ 1848852911502655488
author Othman, Mohammad Lutfi
Hadi, Mahmood Khalid
Abdul Wahab, Noor Izzri
author_facet Othman, Mohammad Lutfi
Hadi, Mahmood Khalid
Abdul Wahab, Noor Izzri
author_sort Othman, Mohammad Lutfi
building UPM Institutional Repository
collection Online Access
description Special Protection Schemes (SPSs), are corrective action schemes that are designed to protect power systems against severe contingency conditions. In planning of SPSs, protecting transmission network from overloading issue due to critical situations has become a serious challenge which needs to be taken into account. In this paper, a Special Protection and Control Scheme (SPCS) based on Differential Evolution (DE) algorithm for optimal generation rescheduling has been applied to mitigate the transmission line overloading in system contingency conditions. The N-1 contingency has been performed for different single line outages under base and increased load in which generation rescheduling strategy has been undertaken to overcome the overloading problem. Simulation results are presented for both pre-and post system emergency situations. The IEEE 30-bus test system was utilised in order to validate the effectiveness of the proposed method.
first_indexed 2025-11-15T10:45:36Z
format Article
id upm-55828
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:45:36Z
publishDate 2017
publisher Universiti Putra Malaysia Press
recordtype eprints
repository_type Digital Repository
spelling upm-558282017-07-05T04:57:29Z http://psasir.upm.edu.my/id/eprint/55828/ A corrective action scheme for contingency monitoring of transmission line overloading Othman, Mohammad Lutfi Hadi, Mahmood Khalid Abdul Wahab, Noor Izzri Special Protection Schemes (SPSs), are corrective action schemes that are designed to protect power systems against severe contingency conditions. In planning of SPSs, protecting transmission network from overloading issue due to critical situations has become a serious challenge which needs to be taken into account. In this paper, a Special Protection and Control Scheme (SPCS) based on Differential Evolution (DE) algorithm for optimal generation rescheduling has been applied to mitigate the transmission line overloading in system contingency conditions. The N-1 contingency has been performed for different single line outages under base and increased load in which generation rescheduling strategy has been undertaken to overcome the overloading problem. Simulation results are presented for both pre-and post system emergency situations. The IEEE 30-bus test system was utilised in order to validate the effectiveness of the proposed method. Universiti Putra Malaysia Press 2017 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55828/1/15-JTS%28S%29-0091-2016-4thProof.pdf Othman, Mohammad Lutfi and Hadi, Mahmood Khalid and Abdul Wahab, Noor Izzri (2017) A corrective action scheme for contingency monitoring of transmission line overloading. Pertanika Journal of Science & Technology, 25 (spec. Jan.). pp. 129-138. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Jan.%202017/15-JTS(S)-0091-2016-4thProof.pdf
spellingShingle Othman, Mohammad Lutfi
Hadi, Mahmood Khalid
Abdul Wahab, Noor Izzri
A corrective action scheme for contingency monitoring of transmission line overloading
title A corrective action scheme for contingency monitoring of transmission line overloading
title_full A corrective action scheme for contingency monitoring of transmission line overloading
title_fullStr A corrective action scheme for contingency monitoring of transmission line overloading
title_full_unstemmed A corrective action scheme for contingency monitoring of transmission line overloading
title_short A corrective action scheme for contingency monitoring of transmission line overloading
title_sort corrective action scheme for contingency monitoring of transmission line overloading
url http://psasir.upm.edu.my/id/eprint/55828/
http://psasir.upm.edu.my/id/eprint/55828/
http://psasir.upm.edu.my/id/eprint/55828/1/15-JTS%28S%29-0091-2016-4thProof.pdf