Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor

Purpose of this study is to determine the relationship between Indoor Air Quality (IAQ) and Sick Building Syndrome (SBS) among staff in two different settings of Private Higher Learning Institutions in Kuala Lumpur and Selangor. The differences in building setting which are retrofitting and purposed...

Full description

Bibliographic Details
Main Authors: Fauzan, Nur Hanisah, Jalaludin, Juliana, Chua, Poh Choo
Format: Article
Language:English
Published: Research India Publications 2016
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/54551/
http://psasir.upm.edu.my/id/eprint/54551/1/Indoor%20Air%20Quality%20and%20Sick%20Building%20Syndrome%20.pdf
_version_ 1848852576527712256
author Fauzan, Nur Hanisah
Jalaludin, Juliana
Chua, Poh Choo
author_facet Fauzan, Nur Hanisah
Jalaludin, Juliana
Chua, Poh Choo
author_sort Fauzan, Nur Hanisah
building UPM Institutional Repository
collection Online Access
description Purpose of this study is to determine the relationship between Indoor Air Quality (IAQ) and Sick Building Syndrome (SBS) among staff in two different settings of Private Higher Learning Institutions in Kuala Lumpur and Selangor. The differences in building setting which are retrofitting and purposed-built building may have different IAQ levels and ventilation system efficiency as well as different in number of reported SBS. 120 respondents consist of male and female administrative staff from Building A and B were participated in this cross sectional comparative study. SBS symptoms measured using validated questionnaire from modified IAQ and Work Environment Symptom Survey while IAQ parameters measured using IAQ devices. Result shows that symptoms of SBS which is stuffy or irritated nose (OR=2.99, 95% CI=1.14-7.88) and fatigue, unusual tiredness or drowsiness (OR=2.58, 95% CI=1.12-5.97) shows a significant association in Building A and B. Besides, there was no significant association between the reported SBS with level of IAQ in Building A and B, however Building A shows an insignificant OR with increasing risk of developing SBS among staff office. After controlling the confounder, there was no significant association between reported SBS with indoor air pollutant in Building A, however result shows an increase risk with insignificant OR of developing SBS when exposed to CO2 (OR=1.92, 95%CI=0.49-7.46), temperature (OR=1.54, 95% CI=0.38-6.19), bacteria (OR=1.72, 95% CI=0.46-6.42) and fungi (OR=1.72, 95% CI=0.46-6.42). While for Building B, there is a significant increased risk of developing SBS when exposed to CO2 (OR=1.67, 95%CI=0.42-5.79), temperature (OR=1.49, 95% CI=0.07-32.36) and bacteria (OR=1.29, 95% CI=0.42-3.99). As a conclusion, purposed-built building is more suitable for the construction of college compared to retrofitting building since retrofitting building showed higher levels of pollutants which exceed the permissible limit. Thus, a proper maintenance of ventilation systems and good housekeeping should be practiced as well as control the source of IAP in the office.
first_indexed 2025-11-15T10:40:16Z
format Article
id upm-54551
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:40:16Z
publishDate 2016
publisher Research India Publications
recordtype eprints
repository_type Digital Repository
spelling upm-545512018-03-28T06:41:06Z http://psasir.upm.edu.my/id/eprint/54551/ Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor Fauzan, Nur Hanisah Jalaludin, Juliana Chua, Poh Choo Purpose of this study is to determine the relationship between Indoor Air Quality (IAQ) and Sick Building Syndrome (SBS) among staff in two different settings of Private Higher Learning Institutions in Kuala Lumpur and Selangor. The differences in building setting which are retrofitting and purposed-built building may have different IAQ levels and ventilation system efficiency as well as different in number of reported SBS. 120 respondents consist of male and female administrative staff from Building A and B were participated in this cross sectional comparative study. SBS symptoms measured using validated questionnaire from modified IAQ and Work Environment Symptom Survey while IAQ parameters measured using IAQ devices. Result shows that symptoms of SBS which is stuffy or irritated nose (OR=2.99, 95% CI=1.14-7.88) and fatigue, unusual tiredness or drowsiness (OR=2.58, 95% CI=1.12-5.97) shows a significant association in Building A and B. Besides, there was no significant association between the reported SBS with level of IAQ in Building A and B, however Building A shows an insignificant OR with increasing risk of developing SBS among staff office. After controlling the confounder, there was no significant association between reported SBS with indoor air pollutant in Building A, however result shows an increase risk with insignificant OR of developing SBS when exposed to CO2 (OR=1.92, 95%CI=0.49-7.46), temperature (OR=1.54, 95% CI=0.38-6.19), bacteria (OR=1.72, 95% CI=0.46-6.42) and fungi (OR=1.72, 95% CI=0.46-6.42). While for Building B, there is a significant increased risk of developing SBS when exposed to CO2 (OR=1.67, 95%CI=0.42-5.79), temperature (OR=1.49, 95% CI=0.07-32.36) and bacteria (OR=1.29, 95% CI=0.42-3.99). As a conclusion, purposed-built building is more suitable for the construction of college compared to retrofitting building since retrofitting building showed higher levels of pollutants which exceed the permissible limit. Thus, a proper maintenance of ventilation systems and good housekeeping should be practiced as well as control the source of IAP in the office. Research India Publications 2016 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/54551/1/Indoor%20Air%20Quality%20and%20Sick%20Building%20Syndrome%20.pdf Fauzan, Nur Hanisah and Jalaludin, Juliana and Chua, Poh Choo (2016) Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor. International Journal of Applied Chemistry, 12 (spec. 1). pp. 57-61. ISSN 0973-1792; ESSN: 0973-9734 https://www.ripublication.com/Volume/ijacv12n1spl.htm Indoor air quality (IAQ); Sick building syndrome (SBS); Indoor air pollutant (IAP); Retrofitting and purposed-built building
spellingShingle Indoor air quality (IAQ); Sick building syndrome (SBS); Indoor air pollutant (IAP); Retrofitting and purposed-built building
Fauzan, Nur Hanisah
Jalaludin, Juliana
Chua, Poh Choo
Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor
title Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor
title_full Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor
title_fullStr Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor
title_full_unstemmed Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor
title_short Indoor Air Quality and Sick Building Syndrome (SBS) among staff in two different private higher learning institution settings in Kuala Lumpur and Selangor
title_sort indoor air quality and sick building syndrome (sbs) among staff in two different private higher learning institution settings in kuala lumpur and selangor
topic Indoor air quality (IAQ); Sick building syndrome (SBS); Indoor air pollutant (IAP); Retrofitting and purposed-built building
url http://psasir.upm.edu.my/id/eprint/54551/
http://psasir.upm.edu.my/id/eprint/54551/
http://psasir.upm.edu.my/id/eprint/54551/1/Indoor%20Air%20Quality%20and%20Sick%20Building%20Syndrome%20.pdf