Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe

Experimental investigations were carried out to study the effect of varying multiple jet impingement plate configurations on Reynolds Number (Re) in a closed conduit. Air was considered as the working fluid. There were six multiple impingement plates used for this experiment where each plate has a d...

Full description

Bibliographic Details
Main Authors: Ramli, M. S., Abu Talib, Abd. Rahim, Harmin, Mohammad Yazdi, Mohd Saiah, H. R.
Format: Conference or Workshop Item
Language:English
Published: Institute of Physics Publishing 2016
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/54033/
http://psasir.upm.edu.my/id/eprint/54033/1/Effect%20of%20multiple%20jet%20impingement%20plate%20configurations%20on%20Reynolds%20Number%20in%20a%20pipe.pdf
_version_ 1848852436375044096
author Ramli, M. S.
Abu Talib, Abd. Rahim
Harmin, Mohammad Yazdi
Mohd Saiah, H. R.
author_facet Ramli, M. S.
Abu Talib, Abd. Rahim
Harmin, Mohammad Yazdi
Mohd Saiah, H. R.
author_sort Ramli, M. S.
building UPM Institutional Repository
collection Online Access
description Experimental investigations were carried out to study the effect of varying multiple jet impingement plate configurations on Reynolds Number (Re) in a closed conduit. Air was considered as the working fluid. There were six multiple impingement plates used for this experiment where each plate has a different hole configurations that include the hole diameter, hole orientation, pitch in x-direction and pitch in y-direction. Four sets of orifice plate with diameter of 0.02, 0.03, 0.04, and 0.05 m were used to get the mass flow rate in the pipe. Air was sucked through the impingement plate for five different settings of suction fan with an interval of 10Hz from 10 to 50Hz. By taking the data for constant suction fan setting at 50Hz, it was found that the impingement hole orientation for both in-line and staggered does not give any effect on the Re obtained since the differences was considerably small and fell within the accepted errors. Meanwhile, impingement hole diameter was found to be directly proportional with the Re obtained. It was also found that the different pitch in multiple hole impingement plate resulted in changes of Re. The results show that the Re was decreasing with higher pitch. The uncertainty analyses for the Re were also presented.
first_indexed 2025-11-15T10:38:03Z
format Conference or Workshop Item
id upm-54033
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:38:03Z
publishDate 2016
publisher Institute of Physics Publishing
recordtype eprints
repository_type Digital Repository
spelling upm-540332018-02-26T06:57:46Z http://psasir.upm.edu.my/id/eprint/54033/ Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe Ramli, M. S. Abu Talib, Abd. Rahim Harmin, Mohammad Yazdi Mohd Saiah, H. R. Experimental investigations were carried out to study the effect of varying multiple jet impingement plate configurations on Reynolds Number (Re) in a closed conduit. Air was considered as the working fluid. There were six multiple impingement plates used for this experiment where each plate has a different hole configurations that include the hole diameter, hole orientation, pitch in x-direction and pitch in y-direction. Four sets of orifice plate with diameter of 0.02, 0.03, 0.04, and 0.05 m were used to get the mass flow rate in the pipe. Air was sucked through the impingement plate for five different settings of suction fan with an interval of 10Hz from 10 to 50Hz. By taking the data for constant suction fan setting at 50Hz, it was found that the impingement hole orientation for both in-line and staggered does not give any effect on the Re obtained since the differences was considerably small and fell within the accepted errors. Meanwhile, impingement hole diameter was found to be directly proportional with the Re obtained. It was also found that the different pitch in multiple hole impingement plate resulted in changes of Re. The results show that the Re was decreasing with higher pitch. The uncertainty analyses for the Re were also presented. Institute of Physics Publishing 2016 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/54033/1/Effect%20of%20multiple%20jet%20impingement%20plate%20configurations%20on%20Reynolds%20Number%20in%20a%20pipe.pdf Ramli, M. S. and Abu Talib, Abd. Rahim and Harmin, Mohammad Yazdi and Mohd Saiah, H. R. (2016) Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe. In: AEROTECH VI - Innovation in Aerospace Engineering and Technology, 8–9 Nov 2016, Kuala Lumpur, Malaysia. (pp. 1-14). http://iopscience.iop.org/article/10.1088/1757-899X/152/1/012012/meta Multiple jet impingement plate configurations; Reynolds Number; Pipe 10.1088/1757-899X/152/1/012012
spellingShingle Multiple jet impingement plate configurations; Reynolds Number; Pipe
Ramli, M. S.
Abu Talib, Abd. Rahim
Harmin, Mohammad Yazdi
Mohd Saiah, H. R.
Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe
title Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe
title_full Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe
title_fullStr Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe
title_full_unstemmed Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe
title_short Effect of multiple jet impingement plate configurations on Reynolds Number in a pipe
title_sort effect of multiple jet impingement plate configurations on reynolds number in a pipe
topic Multiple jet impingement plate configurations; Reynolds Number; Pipe
url http://psasir.upm.edu.my/id/eprint/54033/
http://psasir.upm.edu.my/id/eprint/54033/
http://psasir.upm.edu.my/id/eprint/54033/
http://psasir.upm.edu.my/id/eprint/54033/1/Effect%20of%20multiple%20jet%20impingement%20plate%20configurations%20on%20Reynolds%20Number%20in%20a%20pipe.pdf