The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient

In this study, the fluid structure interaction (FSI) method was utilized to investigate the hemodynamic effects between normal aorta and aorta with Transcatheter Aortic Valve Implantation (TAVI) of paravalvular leakage (PVL). A 3D model of patient specific aorta with annulus diameter of 27.3 mm was...

Full description

Bibliographic Details
Main Authors: Basri, Adi Azriff, Zuber, Muhammad, Zakaria, Mohamad Shukri, Basri, Ernnie Illyani, Abdul Aziz, Ahmad Fazli, Mohd Ali, Rosli, Tamagawa, Masaaki, Ahmad, Kamarul Ariffin
Format: Article
Language:English
Published: American Scientific Publishers 2016
Online Access:http://psasir.upm.edu.my/id/eprint/53010/
http://psasir.upm.edu.my/id/eprint/53010/1/The%20hemodynamic%20effects%20of%20paravalvular%20leakage%20using%20fluid%20structure%20interaction%3B%20transcatheter%20aortic%20valve%20implantation%20patient.pdf
_version_ 1848852193984118784
author Basri, Adi Azriff
Zuber, Muhammad
Zakaria, Mohamad Shukri
Basri, Ernnie Illyani
Abdul Aziz, Ahmad Fazli
Mohd Ali, Rosli
Tamagawa, Masaaki
Ahmad, Kamarul Ariffin
author_facet Basri, Adi Azriff
Zuber, Muhammad
Zakaria, Mohamad Shukri
Basri, Ernnie Illyani
Abdul Aziz, Ahmad Fazli
Mohd Ali, Rosli
Tamagawa, Masaaki
Ahmad, Kamarul Ariffin
author_sort Basri, Adi Azriff
building UPM Institutional Repository
collection Online Access
description In this study, the fluid structure interaction (FSI) method was utilized to investigate the hemodynamic effects between normal aorta and aorta with Transcatheter Aortic Valve Implantation (TAVI) of paravalvular leakage (PVL). A 3D model of patient specific aorta with annulus diameter of 27.3 mm was developed using MIMICS software. In this research, a similar TAVI valve model by referring to SXT 26 Edwards SAPIENT valve was drawn using CATIA software with valve opening of 100%. The two way of fluid structure interaction analysis has been performed using ANSYS 14.5 software (ANSYS Inc. Canonsburg, PA, USA). The results revealed that the undersized TAVI valve lead to PVL. It was noticed that the PVL happened at the gap in-between the TAVI valve and annulus diameter which is not completely round in shape. This phenomenon produced recirculation flow at the right side of ascending aorta after the flow passing through the valve. It has been proven that the PVL caused a huge impact on the losses of the mass flow rate and also recirculation of blood flow which may lead to blood thrombosis. Furthermore, the data shows that PVL causes higher aortic wall deformation instead of normal aortic condition and may lead to migration of the valve. Consequently, PVL may cause other serious problems such as stroke, arrhythmias and coronary ischemia, which required reoperation.
first_indexed 2025-11-15T10:34:12Z
format Article
id upm-53010
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:34:12Z
publishDate 2016
publisher American Scientific Publishers
recordtype eprints
repository_type Digital Repository
spelling upm-530102022-05-25T03:26:31Z http://psasir.upm.edu.my/id/eprint/53010/ The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient Basri, Adi Azriff Zuber, Muhammad Zakaria, Mohamad Shukri Basri, Ernnie Illyani Abdul Aziz, Ahmad Fazli Mohd Ali, Rosli Tamagawa, Masaaki Ahmad, Kamarul Ariffin In this study, the fluid structure interaction (FSI) method was utilized to investigate the hemodynamic effects between normal aorta and aorta with Transcatheter Aortic Valve Implantation (TAVI) of paravalvular leakage (PVL). A 3D model of patient specific aorta with annulus diameter of 27.3 mm was developed using MIMICS software. In this research, a similar TAVI valve model by referring to SXT 26 Edwards SAPIENT valve was drawn using CATIA software with valve opening of 100%. The two way of fluid structure interaction analysis has been performed using ANSYS 14.5 software (ANSYS Inc. Canonsburg, PA, USA). The results revealed that the undersized TAVI valve lead to PVL. It was noticed that the PVL happened at the gap in-between the TAVI valve and annulus diameter which is not completely round in shape. This phenomenon produced recirculation flow at the right side of ascending aorta after the flow passing through the valve. It has been proven that the PVL caused a huge impact on the losses of the mass flow rate and also recirculation of blood flow which may lead to blood thrombosis. Furthermore, the data shows that PVL causes higher aortic wall deformation instead of normal aortic condition and may lead to migration of the valve. Consequently, PVL may cause other serious problems such as stroke, arrhythmias and coronary ischemia, which required reoperation. American Scientific Publishers 2016-10 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/53010/1/The%20hemodynamic%20effects%20of%20paravalvular%20leakage%20using%20fluid%20structure%20interaction%3B%20transcatheter%20aortic%20valve%20implantation%20patient.pdf Basri, Adi Azriff and Zuber, Muhammad and Zakaria, Mohamad Shukri and Basri, Ernnie Illyani and Abdul Aziz, Ahmad Fazli and Mohd Ali, Rosli and Tamagawa, Masaaki and Ahmad, Kamarul Ariffin (2016) The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient. Journal of Medical Imaging and Health Informatics, 6 (6). pp. 1513-1518. ISSN 2156-7018; ESSN: 2156-7026 https://www.ingentaconnect.com/content/asp/jmihi/2016/00000006/00000006/art00027;jsessionid=28bi89wssa91e.x-ic-live-01 10.1166/jmihi.2016.1840
spellingShingle Basri, Adi Azriff
Zuber, Muhammad
Zakaria, Mohamad Shukri
Basri, Ernnie Illyani
Abdul Aziz, Ahmad Fazli
Mohd Ali, Rosli
Tamagawa, Masaaki
Ahmad, Kamarul Ariffin
The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
title The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
title_full The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
title_fullStr The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
title_full_unstemmed The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
title_short The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
title_sort hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient
url http://psasir.upm.edu.my/id/eprint/53010/
http://psasir.upm.edu.my/id/eprint/53010/
http://psasir.upm.edu.my/id/eprint/53010/
http://psasir.upm.edu.my/id/eprint/53010/1/The%20hemodynamic%20effects%20of%20paravalvular%20leakage%20using%20fluid%20structure%20interaction%3B%20transcatheter%20aortic%20valve%20implantation%20patient.pdf