Study on the electrical equivalent circuit model of lightning fault cause in power grid system

Transmission line systems are exposed to various fault causes that can reduce the grid performance. One of the fault causes is due to lightning strike. The judgement of the lightning fault cause is usually done after the tripping is detected by the protection operation system and its consume time. A...

Full description

Bibliographic Details
Main Authors: Asman, Saidatul Habsah, Zainul Abidin, Aidil Azwin, Mohd Ngah, Nurul Ainatul Rahmah, Ab Aziz, Nur Fadilah, Ab. Kadir, Mohd Zainal, Ahmad Mustafa, Nur Badariah, Leong, Yeng Weng
Format: Conference or Workshop Item
Published: IEEE 2022
Online Access:http://psasir.upm.edu.my/id/eprint/44513/
_version_ 1848850444875464704
author Asman, Saidatul Habsah
Zainul Abidin, Aidil Azwin
Mohd Ngah, Nurul Ainatul Rahmah
Ab Aziz, Nur Fadilah
Ab. Kadir, Mohd Zainal
Ahmad Mustafa, Nur Badariah
Leong, Yeng Weng
author_facet Asman, Saidatul Habsah
Zainul Abidin, Aidil Azwin
Mohd Ngah, Nurul Ainatul Rahmah
Ab Aziz, Nur Fadilah
Ab. Kadir, Mohd Zainal
Ahmad Mustafa, Nur Badariah
Leong, Yeng Weng
author_sort Asman, Saidatul Habsah
building UPM Institutional Repository
collection Online Access
description Transmission line systems are exposed to various fault causes that can reduce the grid performance. One of the fault causes is due to lightning strike. The judgement of the lightning fault cause is usually done after the tripping is detected by the protection operation system and its consume time. Another method to conclude the lightning fault cause is detected using lightning map sensor but, the supplement method is quite expensive and did not employed in the whole grid system in Malaysia. Furthermore, the grid systems are utilized with the Digital Fault Recorder (DFR) as an intelligent electronic device to detect and restore the fault data. By using the voltage and current waveform data obtained from the DFR, the fault behavior could be studied. Therefore, in this paper, an equivalent circuit model has been investigated to understand the correlation between the fault phenomena due to lightning and its voltage and current profile acquired from the DFR.
first_indexed 2025-11-15T10:06:24Z
format Conference or Workshop Item
id upm-44513
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T10:06:24Z
publishDate 2022
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling upm-445132023-08-28T03:47:02Z http://psasir.upm.edu.my/id/eprint/44513/ Study on the electrical equivalent circuit model of lightning fault cause in power grid system Asman, Saidatul Habsah Zainul Abidin, Aidil Azwin Mohd Ngah, Nurul Ainatul Rahmah Ab Aziz, Nur Fadilah Ab. Kadir, Mohd Zainal Ahmad Mustafa, Nur Badariah Leong, Yeng Weng Transmission line systems are exposed to various fault causes that can reduce the grid performance. One of the fault causes is due to lightning strike. The judgement of the lightning fault cause is usually done after the tripping is detected by the protection operation system and its consume time. Another method to conclude the lightning fault cause is detected using lightning map sensor but, the supplement method is quite expensive and did not employed in the whole grid system in Malaysia. Furthermore, the grid systems are utilized with the Digital Fault Recorder (DFR) as an intelligent electronic device to detect and restore the fault data. By using the voltage and current waveform data obtained from the DFR, the fault behavior could be studied. Therefore, in this paper, an equivalent circuit model has been investigated to understand the correlation between the fault phenomena due to lightning and its voltage and current profile acquired from the DFR. IEEE 2022 Conference or Workshop Item PeerReviewed Asman, Saidatul Habsah and Zainul Abidin, Aidil Azwin and Mohd Ngah, Nurul Ainatul Rahmah and Ab Aziz, Nur Fadilah and Ab. Kadir, Mohd Zainal and Ahmad Mustafa, Nur Badariah and Leong, Yeng Weng (2022) Study on the electrical equivalent circuit model of lightning fault cause in power grid system. In: 2022 IEEE International Conference on Power Systems Technology (POWERCON), 12-14 Sept. 2022, Kuala Lumpur, Malaysia. . https://ieeexplore.ieee.org/document/9929801 10.1109/POWERCON53406.2022.9929801
spellingShingle Asman, Saidatul Habsah
Zainul Abidin, Aidil Azwin
Mohd Ngah, Nurul Ainatul Rahmah
Ab Aziz, Nur Fadilah
Ab. Kadir, Mohd Zainal
Ahmad Mustafa, Nur Badariah
Leong, Yeng Weng
Study on the electrical equivalent circuit model of lightning fault cause in power grid system
title Study on the electrical equivalent circuit model of lightning fault cause in power grid system
title_full Study on the electrical equivalent circuit model of lightning fault cause in power grid system
title_fullStr Study on the electrical equivalent circuit model of lightning fault cause in power grid system
title_full_unstemmed Study on the electrical equivalent circuit model of lightning fault cause in power grid system
title_short Study on the electrical equivalent circuit model of lightning fault cause in power grid system
title_sort study on the electrical equivalent circuit model of lightning fault cause in power grid system
url http://psasir.upm.edu.my/id/eprint/44513/
http://psasir.upm.edu.my/id/eprint/44513/
http://psasir.upm.edu.my/id/eprint/44513/